Skip to content
verify mcp Beta VerifyMCP is currently in beta. If you notice any issues, get in touch and we’ll put it right.

Flow Pack

REMOTE · FLOW-PACK.NEROLABS.WORKERS.DEV

Pipe sizing, heat loss, gas record checks and emergency triage for UK plumbers' AI assistants

+3 this week 64 Trust /100

Last scanned (17 hours ago)

Scores higher than 46% of remote servers

Reachable. Last reached 21 Nov 2026.

Category Health and Science

Trust breakdown (7 categories)

How this component scores in each security and reliability category. Every signal is checked automatically against the live server, and we only credit what we can confirm. How we score → Why this is hard to score →

Endpoint Security63
  • The endpoint's TLS certificate is valid, in date, and uses a strong key. View diagnostics → Pass
  • No authorisation is required to call this server. Nothing on it is marked destructive, but we can't show that an anonymous caller can only read: full credit needs the server to list at least one tool and every tool to be verifiably read-only. We use a best-effort check of tool names and descriptions to tell read-only tools from tools that change things, so some genuinely read-only tools may not get full credit. Names that start with a read verb (get, list, read, search and similar) and accurate readOnlyHint annotations help. Meet that to earn full credit, or require authorisation. See how to fix → View diagnostics → Partial
  • HTTPS enforcement could not be verified: the plaintext port answered with HTTP 405, which proves neither a plaintext path nor enforcement. View diagnostics → Unverified
  • HSTS check failed: the Strict-Transport-Security header is absent. See how to fix → View diagnostics → Fail
  • DNSSEC check failed: this domain isn't protected by DNSSEC. See how to fix → View diagnostics → Fail
Transport & Reachability100
Schema Quality & AI Usability53
  • AI-judged instruction clarity (good).Pass
  • Context-footprint check failed: tool/resource definitions use about 2965 tokens (~370/item across 8 items; 8 tools + 0 resources), over budget; trim descriptions and params. See how to fix → Fail
  • Usage-examples check failed: none of the tools include examples. See how to fix → Fail
Stability & Change Management27
  • Stability observed for 8 of 30 days with no destabilising changes; credit accrues until the full window elapses.Partial
Tool Coverage93
  • 100% of tools have a non-trivial description (not blank, and not just the tool's name).Pass
  • 78% of tool parameters carry a description.Partial
Tool Safety100
  • No prompt-injection markers were found in the server instructions, tool names or descriptions we captured.Pass
  • We read all 8 captured tool definition(s), and no name or description among them implies an irreversible operation.Pass
  • An AI judge read all 9 captured unit(s) of tool text and found none that tries to manipulate the model reading it.Pass
Capabilities60
  • Spec-recency check failed: implements MCP spec 2025-06-18; the latest is 2026-07-28. See how to fix → Fail
What we tested

Checks we ran (12)

  • TLS certificate
  • Authorization
  • HSTS header
  • DNSSEC
  • Transport
  • Schema quality
  • Stability
  • Tool coverage
  • Injection markers
  • Destructive annotations
  • Judged manipulation
  • MCP protocol

Checks we could not complete (1)

These are gaps on our side, not findings about this hosted endpoint. We only credit what we can confirm, so a category made up entirely of them scores 0.

  • HTTPS in Endpoint SecurityHTTPS enforcement could not be verified: the plaintext port answered with HTTP 405, which proves neither a plaintext path nor enforcement.

Does not apply to this hosted endpoint (2)

  • Supply Chain SecurityScored on package channels only. This is a hosted endpoint, so there is nothing to install or inspect.
  • Provenance & TransparencyScored on package channels only. This is a hosted endpoint, so there is nothing to install or inspect.

The score does not measure everything. What the score does not measure →

Changelog

Every change we have recorded for this component, newest first. Security-relevant changes are always shown. ▲ marks a change for the better, ▼ a change for the worse; unmarked changes are neutral.

  • 20 Nov 26 +1

    No change was recorded against any check on this day. Stability & Change Management went from 20 to 23. That category is still filling its 30-day observation window: 6 days of observed history at the previous scan, 7 at this one. The score rises as the window fills, whether or not the server changes.

  • 18 Nov 26 +1

    No change was recorded against any check on this day. Stability & Change Management went from 13 to 17. That category is still filling its 30-day observation window: 4 days of observed history at the previous scan, 5 at this one. The score rises as the window fills, whether or not the server changes.

  • 15 Nov 26 +1

    No change was recorded against any check on this day. Stability & Change Management went from 3 to 7. That category is still filling its 30-day observation window: 1 days of observed history at the previous scan, 2 at this one. The score rises as the window fills, whether or not the server changes.

  • 14 Nov 26 0
    • Stability: unverified → 0.03 ▲ functional
  • 13 Nov 26 61

    First indexed and scored.

Diagnostics

Diagnostic detail from the automated scan of this channel: what the scanner observed at each step, so you can see exactly where a check passed or failed. It is informational only and never changes the trust score.

Captured 21 Nov 2026 · Probed https://flow-pack.nerolabs.workers.dev/mcp

TLS valid

Negotiated TLS 1.3 with TLS_AES_128_GCM_SHA256 .

Subject Issuer Valid from Valid until Key Signature Serial
CN=nerolabs.workers.dev CN=YE1,O=Let's Encrypt,C=US 10 Nov 2026 8 Feb 2027 ECDSA 256 ECDSA-SHA384 6de4049323d6abaa327886d7b5c76757b3a
SANs: *.nerolabs.workers.dev, nerolabs.workers.dev
CN=YE1,O=Let's Encrypt,C=US (CA) CN=Root YE,O=ISRG,C=US 3 Sept 2025 2 Sept 2028 ECDSA 384 ECDSA-SHA384 5ddd70dd31f801c85c186a7a04b80afe
CN=Root YE,O=ISRG,C=US (CA) CN=ISRG Root X2,O=Internet Security Research Group,C=US 13 May 2026 2 Sept 2032 ECDSA 384 ECDSA-SHA384 872165fc34b6e5fba8add5b3705fb53a
CN=ISRG Root X2,O=Internet Security Research Group,C=US (CA) CN=ISRG Root X1,O=Internet Security Research Group,C=US 13 May 2026 2 Sept 2032 ECDSA 384 SHA256-RSA 6c8f1dc727c7117f7baf853ac980f9cd

Background: What to check on a remote MCP endpoint →

DNSSEC insecure

Validation of flow-pack.nerolabs.workers.dev. — Not signed

Zone DS Keys Algorithms Outcome
. Trust anchor 20326, 38696 8, 8 Verified
dev. DS published 60074 8 Verified
workers.dev. No DS Unsigned (proven) parent-signed NSEC/NSEC3 proves an unsigned delegation
Authentication No authorisation required

The endpoint answered without asking for a token. Anyone who knows the URL can reach it.

Result No authorisation required
HTTP status 200

Background: How OAuth 2.1 works in the 2026 MCP spec →

Transports 2 probes
Transport URL Outcome Status Location
streamable-http https://flow-pack.nerolabs.workers.dev/mcp Verified 200
http (plaintext) http://flow-pack.nerolabs.workers.dev/mcp Inconclusive 405
MCP tools · 8 exposed · ~2,782 tokens

The tools this component advertises to a client, with an estimated token cost for each. Expand a tool to see its parameters and schema. The per-tool counts are indicative and are not scored directly; the schema's total context footprint is one signal in Schema Quality & AI Usability. A tool's description is untrusted text the model reads on every call, which is what makes this list a security surface and not just an inventory: how tool poisoning works →

Tool Tokens
check_gas_record ~462

Checks a filled landlord gas safety record (CP12) or a boiler commissioning record and lists errors and warnings: missing required fields, failed tightness, flue, ventilation or safety device checks, CO/CO2 ratio over the limits, gas rate off the rated input, meter pressure out of range, an unsafe appliance marked safe, and the correct next due date (keeping the anniversary for checks done up to 2 months early). Gas safety record fields: property_address, landlord_name, landlord_address, engineer_name, gas_safe_registration_number, engineer_licence_number, check_date, previous_record_expiry_date, next_check_due, engineer_signature, tightness_test_passed, emergency_control_accessible, meter_standing_pressure_mbar, meter_working_pressure_mbar, appliances[] {type, make, model, location, flue_type, flue_check_passed, ventilation_satisfactory, safety_devices_ok, co_ppm, co2_percent, co_co2_ratio, rated_heat_input_kw_gross, measured_gas_rate_m3_h, inlet_working_pressure_mbar, status (safe, ncs, at_risk, immediately_dangerous), safe_to_use, action_taken}. Commissioning fields: property_address, engineer_name, commissioning_date, boiler_type, system_flushed, inhibitor_added, inhibitor_name, filter_fitted, water_hardness_ppm, scale_reducer_fitted, condensate_external_pipe_mm, controls_time_and_temperature, combi_extra_measure, co_alarm_fitted, building_regs_notified, dhw_flow_l_min, dhw_temp_rise_c, appliances[] {make, model, serial_number, co_ppm, co2_percent, min_rate {co_ppm, co2_percent}, rated_heat_input_kw_gross, measured_gas_rate_m3_h}. Up to 30 appliances.

NameTypeReqDescription
recordobjectyesThe filled fields (see the description).
record_typestringyes–
tradeobject–Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…

No output schema declared.

No examples provided.

check_notifiable_work ~239

For plumbing and heating jobs in England or Wales: does it need a Gas Safe registered engineer, an unvented (G3) qualified installer, building regulations notification (Approved Documents G, J, L and others) and a water company notice (Water Fittings Regulations, regulation 5)? Returns, per job, who can do it, the self-certification route (competent person scheme within 30 days, or building control before starting) and what to do next, including CO alarm and Boiler Plus rules. Typical call: {"nation":"england","work":["gas_boiler_replacement","unvented_cylinder_new"]}.

NameTypeReqDescription
nationstring–Default england.
tradeobject–Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…
water_approved_contractorboolean–True if the installer is a water approved contractor (for example WaterSafe).
workarrayyesOne or more jobs.

No output schema declared.

No examples provided.

emergency_triage ~342

For a homeowner reporting a problem: the safe first steps to do now, what not to do, who to call first (the gas emergency service 0800 111 999 for a gas smell or CO alarm), whether it is a real emergency, and an `urgency` value of routine, soon or emergency that matches Nero Work's three job speeds, raised for water near electrics, a bulging ceiling, a vulnerable person in the cold, or water that cannot be stopped. Also returns `nero_work_job` (urgency, category, summary) ready to post. Typical call: {"situation":"no_heat","vulnerable_people":true,"outside_temp_c":2,"other_heating_available":false}.

NameTypeReqDescription
ceiling_bulgingboolean––
nationstring–Changes the gas emergency number for Northern Ireland.
only_toiletboolean––
other_heating_availableboolean––
outside_temp_cnumber––
pipe_splitboolean––
sewage_insideboolean––
situationstringyes–
tradeobject–Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…
vulnerable_peopleboolean–Elderly, very young, disabled or medically vulnerable person in the home.
water_near_electricsboolean––
water_stoppedboolean–Has turning off the stop tap or valve stopped the water?

No output schema declared.

No examples provided.

list_capabilities ~47

Lists Flow Pack's tools, what it covers (nations, pipe materials, gases, record types, emergency situations) and what it deliberately does not do. Free, needs no input.

Input schema present but exposes no named parameters.

No output schema declared.

No examples provided.

size_heat_source ~446

Works out the heat loss of each room (fabric U x A x delta T plus ventilation 0.33 x air changes x volume x delta T) and the total, then sizes a combi, system or regular boiler, or a heat pump, to the nearest common size. Combi sizing also checks the hot water load (flow x temperature rise). Give each room's type, size and its walls, windows, roof and floor with U values, or construction presets for indicative values. Returns per-room losses with every element's working, the total, the size, `status` (indicative when presets were used), `must_check` and sources. Typical call: {"heat_source":"heat_pump","outside_design_temp_c":-3,"rooms":[{"name":"Lounge","type":"living","floor_area_m2":20,"elements":[{"type":"wall","area_m2":7.8,"construction":"cavity_wall_unfilled"},{"type":"window","area_m2":1.8,"construction":"double_glazed_old"}]}]}.

NameTypeReqDescription
cylinder_litresnumber–System or regular boiler: cylinder size. Default 150.
heat_sourcestring–Default combi_boiler.
hot_water_flow_l_minnumber–Combi: wanted hot water flow. Default 12.
hot_water_priorityboolean–Default true (reheat load not added).
hot_water_temp_rise_cnumber–Combi: temperature rise. Default 35.
margin_percentnumber–Added to the heating load. Default 10 for boilers, 0 for heat pumps.
outside_design_temp_cnumber–Local outside design temperature. Default -3.
reheat_hoursnumber–Wanted reheat time. Default 1.
roomsarrayyesUp to 40 rooms.
tradeobject–Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…

No output schema declared.

No examples provided.

size_pipe ~765

Sizes a hot or cold water pipe, or a low-pressure gas pipe, and shows the working. Water: design flow (from outlets, with a simple in-use-at-once rule, or a flow you give), velocity against a limit (1.5 m/s default), pressure loss per metre and in total, and the pressure left at the outlet if you give the supply pressure. Gas: flow from the gross heat input of the appliances fed, pressure drop against the 1 mbar natural gas (2.5 mbar LPG) allowance, with a meter capacity warning. Returns `recommended` (smallest size that passes), `sizes_considered`, `must_check` (points the engineer confirms) and sources. Calculated from fluid physics (Darcy-Weisbach); no BS EN 806 or BS 6891 tables are reproduced. Typical calls: {"medium":"gas","heat_input_kw_gross":30,"run_length_m":12,"fittings":{"elbows":5}} or {"medium":"water","service":"cold","outlets":[{"type":"bath"},{"type":"kitchen_sink"},{"type":"basin"},{"type":"wc"},{"type":"shower_mixer"}],"run_length_m":15,"supply_pressure_bar":2.5,"height_rise_m":3}.

NameTypeReqDescription
allowed_drop_mbarnumber–Gas only. Default 1 natural gas, 2.5 LPG.
design_flow_l_snumber–Water only: design flow in litres a second, if known (overrides outlets).
fittingsobject–Count of fittings on the run. If left out, 30% is added to the length instead (or fittings_allowance_percent).
fittings_allowance_percentnumber–Length added for fittings when they are not counted. Default 30.
gasstring–Gas only. Default natural_gas.
gas_flow_m3_hnumber–Gas only: gas flow, if already known.
heat_input_kw_grossnumber–Gas only: total gross heat input of every appliance this pipe feeds (data plate).
heat_input_kw_netnumber–Gas only: if only the net figure is known.
height_rise_mnumber–Water only: height gained from start to outlet (negative if it falls).
materialstring–Water: copper (default), plastic, mdpe. Gas: copper (default), steel, csst.
max_velocity_m_snumber–Water only. Default 1.5.
mediumstringyes–
min_pressure_at_outlet_barnumber–Water only: pressure needed at the end. Default 1.0 bar.
outletsarray–Water only: outlets this pipe feeds.
pipe_size_mmnumber–Check only this nominal size.
run_length_mnumberyesMeasured pipe length, metres (from the meter for gas, from the stop tap or cylinder for water).
servicestring–Water only. Default cold.
simultaneous_outletsnumber–Water only: how many outlets run at once. Default: square root of the number of outlets, rounded.
supply_pressure_barnumber–Water only: working pressure at the start of the run (measured with water flowing).
tradeobject–Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…
water_temp_cnumber–Water only. Default 10 cold, 60 hot.

No output schema declared.

No examples provided.

size_radiators ~287

For each room's heat loss, works out the rated (delta T 50) radiator output needed at the system's flow and return temperatures, using output = rated x (mean water to air difference / 50) ^ 1.3. Shows how far an existing radiator falls short, the water flow per radiator, indicative lengths by panel type, and with compare_flow_temp_c how much bigger radiators must be at a lower flow temperature (for example 70 C boiler to 45 C heat pump). Typical call: {"flow_temp_c":45,"rooms":[{"name":"Lounge","heat_loss_w":1500,"existing_rated_output_w":1800}],"compare_flow_temp_c":70}.

NameTypeReqDescription
compare_flow_temp_cnumber––
compare_return_temp_cnumber––
flow_temp_cnumber–Default 70.
radiator_exponentnumber–Default 1.3.
return_temp_cnumber–Default flow minus 10 (minus 5 at 55 C or lower).
roomsarrayyes–
tradeobject–Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…

No output schema declared.

No examples provided.

trade_profile ~194

Checks the business's own details (Nero Trade Profile v1: trading name, Companies House number, registration scheme and number, postcode, contact) and returns them cleaned, with a stable `nero_trade_ref` computed from the scheme registration (licence_body gas_safe plus the Gas Safe registration number) or the company number. The same shape and reference as Spark Pack, so one business keeps one reference across trades. The same object, given as `trade` to the other tools, prefills records. Flow Pack stores nothing. The same profile and reference can later be used to sign the business into Nero Work, the agent job exchange for trades.

NameTypeReqDescription
tradeobjectyesOptional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…

No output schema declared.

No examples provided.

Install

How do I install the Flow Pack MCP server?

Flow Pack is a hosted endpoint at https://flow-pack.nerolabs.workers.dev/mcp, so there is nothing to install locally. Ready-made configuration for Claude, Cursor, VS Code, Codex and 5 more is on this page, copied from each client's own documentation.

remote · flow-pack.nerolabs.workers.dev

# add to Claude Code
claude mcp add --transport http nero-engine-flow-pack 'https://flow-pack.nerolabs.workers.dev/mcp'
Common questions

What is the Flow Pack MCP server?

Flow Pack is an MCP server listed in the public MCP registry as io.github.Nero-Engine/flow-pack. Pipe sizing, heat loss, gas record checks and emergency triage for UK plumbers' AI assistants. This page covers its hosted endpoint (https://flow-pack.nerolabs.workers.dev/mcp).

Is the Flow Pack MCP server safe to use?

Flow Pack scores 64 out of 100 on VerifyMCP. That is a record of what we were able to check automatically, not an endorsement. The category breakdown on this page shows every signal behind the number, including the ones we could not confirm.

What tools does the Flow Pack MCP server expose?

Flow Pack exposes 8 tools: list_capabilities, size_pipe, size_heat_source, size_radiators, check_notifiable_work, and 3 more. Their descriptions and schemas cost roughly 2,782 tokens of context every time the server is loaded.

Does the Flow Pack MCP server require authentication?

No. We connected to Flow Pack without credentials and it answered, so anything it exposes is reachable by anyone who knows the address.

Is the Flow Pack MCP server still maintained?

Flow Pack is still listed as active in the MCP registry. We last reached this channel on 21 November 2026. Those dates come from our own scans of the registry and the channel itself, not from anything the publisher announced.

What did VerifyMCP test on the Flow Pack MCP server?

VerifyMCP ran 12 checks on Flow Pack, covering TLS certificate, Authorization, HSTS header, DNSSEC and 8 more. One item could not be completed, a gap on our side rather than a finding about Flow Pack: HTTPS. Supply Chain Security and Provenance & Transparency do not apply to a hosted endpoint, so they were not tested. The score does not measure everything, and the scoring documentation lists what it leaves out.