# Flow Pack (remote · flow-pack.nerolabs.workers.dev)

Pipe sizing, heat loss, gas record checks and emergency triage for UK plumbers' AI assistants

- Trust score: 64/100 (medium)
- Change this week: +3
- Registry status: active
- Liveness: live
- Owner verified: no
- Last scored: 2026-11-21

## Components

- remote · `flow-pack.nerolabs.workers.dev`: 64/100 (this document), [markdown](https://verifymcp.io/servers/nero-engine-flow-pack/flow-pack.md), [page](https://verifymcp.io/servers/nero-engine-flow-pack/flow-pack)

## Channel facts

- Endpoint: `https://flow-pack.nerolabs.workers.dev/mcp`
- Transports: `streamable-http`
- Auth: `none`
- Version: `1.1.0`

## Trust breakdown

How this component scores in each security and reliability category. Every signal is checked automatically against the live server, and we only credit what we can confirm. Scores are 0–100 per category. Scoring method: https://verifymcp.io/docs/scoring (what has changed: https://verifymcp.io/docs/scoring/changelog)

Scored 2026-11-21.

- **Endpoint Security**: 63/100
  - The endpoint's TLS certificate is valid, in date, and uses a strong key.
  - No authorisation is required to call this server. Nothing on it is marked destructive, but we can't show that an anonymous caller can only read: full credit needs the server to list at least one tool and every tool to be verifiably read-only. We use a best-effort check of tool names and descriptions to tell read-only tools from tools that change things, so some genuinely read-only tools may not get full credit. Names that start with a read verb (get, list, read, search and similar) and accurate readOnlyHint annotations help. Meet that to earn full credit, or require authorisation.
  - HTTPS enforcement could not be verified: the plaintext port answered with HTTP 405, which proves neither a plaintext path nor enforcement.
  - HSTS check failed: the Strict-Transport-Security header is absent.
  - DNSSEC check failed: this domain isn't protected by DNSSEC.
- **Transport & Reachability**: 100/100
  - Verified streamable-http transport via a live MCP handshake.
- **Schema Quality & AI Usability**: 53/100
  - AI-judged instruction clarity (good).
  - Context-footprint check failed: tool/resource definitions use about 2965 tokens (~370/item across 8 items; 8 tools + 0 resources), over budget; trim descriptions and params.
  - Usage-examples check failed: none of the tools include examples.
- **Stability & Change Management**: 27/100
  - Stability observed for 8 of 30 days with no destabilising changes; credit accrues until the full window elapses.
- **Tool Coverage**: 93/100
  - 100% of tools have a non-trivial description (not blank, and not just the tool's name).
  - 78% of tool parameters carry a description.
- **Tool Safety**: 100/100
  - No prompt-injection markers were found in the server instructions, tool names or descriptions we captured.
  - We read all 8 captured tool definition(s), and no name or description among them implies an irreversible operation.
  - An AI judge read all 9 captured unit(s) of tool text and found none that tries to manipulate the model reading it.
- **Capabilities**: 60/100
  - Spec-recency check failed: implements MCP spec 2025-06-18; the latest is 2026-07-28.

## Install

### How do I install the Flow Pack MCP server?

Flow Pack is a hosted endpoint at https://flow-pack.nerolabs.workers.dev/mcp, so there is nothing to install locally. Ready-made configuration for Claude, Cursor, VS Code, Codex and 5 more is on this page, copied from each client's own documentation.

### Claude

```bash
claude mcp add --transport http nero-engine-flow-pack 'https://flow-pack.nerolabs.workers.dev/mcp'
```

### Cursor

```json
{
  "mcpServers": {
    "nero-engine-flow-pack": {
      "url": "https://flow-pack.nerolabs.workers.dev/mcp"
    }
  }
}
```

### VS Code

```json
{
  "servers": {
    "nero-engine-flow-pack": {
      "type": "http",
      "url": "https://flow-pack.nerolabs.workers.dev/mcp"
    }
  }
}
```

### Codex

```toml
[mcp_servers.nero-engine-flow-pack]
url = "https://flow-pack.nerolabs.workers.dev/mcp"
```

### opencode

```json
{
  "$schema": "https://opencode.ai/config.json",
  "mcp": {
    "nero-engine-flow-pack": {
      "type": "remote",
      "url": "https://flow-pack.nerolabs.workers.dev/mcp",
      "enabled": true
    }
  }
}
```

### OpenClaw

```bash
openclaw mcp add nero-engine-flow-pack --url 'https://flow-pack.nerolabs.workers.dev/mcp' --transport streamable-http
```

### Hermes

```yaml
mcp_servers:
  nero-engine-flow-pack:
    url: "https://flow-pack.nerolabs.workers.dev/mcp"
```

### Netclaw

```json
{
  "McpServers": {
    "nero-engine-flow-pack": {
      "Transport": "http",
      "Url": "https://flow-pack.nerolabs.workers.dev/mcp"
    }
  }
}
```

### Vellum

```bash
assistant mcp add nero-engine-flow-pack -t streamable-http -u 'https://flow-pack.nerolabs.workers.dev/mcp'
```

### Other

```json
{
  "mcpServers": {
    "nero-engine-flow-pack": {
      "type": "http",
      "url": "https://flow-pack.nerolabs.workers.dev/mcp"
    }
  }
}
```

The mcpServers block is a cross-client convention. Remote transports vary, so check your client's docs.

## Changelog

Every change recorded for this component, newest first. Days that predate change tracking, or that we cannot explain, say so: "we were watching and nothing happened" and "we were not watching" are different claims.

### 2026-11-20 (score 64, +1)

No change was recorded against any check on this day. Stability & Change Management went from 20 to 23. That category is still filling its 30-day observation window: 6 days of observed history at the previous scan, 7 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-11-18 (score 63, +1)

No change was recorded against any check on this day. Stability & Change Management went from 13 to 17. That category is still filling its 30-day observation window: 4 days of observed history at the previous scan, 5 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-11-15 (score 62, +1)

No change was recorded against any check on this day. Stability & Change Management went from 3 to 7. That category is still filling its 30-day observation window: 1 days of observed history at the previous scan, 2 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-11-14 (score 61, 0)

- [functional improvement] Stability: unverified → 0.03

### 2026-11-13 (score 61)

First indexed and scored.

## MCP tools (8)

### `list_capabilities` (~47 tokens)

What Flow Pack can do

Lists Flow Pack's tools, what it covers (nations, pipe materials, gases, record types, emergency situations) and what it deliberately does not do. Free, needs no input.

### `size_pipe` (~765 tokens)

Water or gas pipe size, velocity and pressure loss

Sizes a hot or cold water pipe, or a low-pressure gas pipe, and shows the working. Water: design flow (from outlets, with a simple in-use-at-once rule, or a flow you give), velocity against a limit (1.5 m/s default), pressure loss per metre and in total, and the pressure left at the outlet if you give the supply pressure. Gas: flow from the gross heat input of the appliances fed, pressure drop against the 1 mbar natural gas (2.5 mbar LPG) allowance, with a meter capacity warning. Returns `recommended` (smallest size that passes), `sizes_considered`, `must_check` (points the engineer confirms) and sources. Calculated from fluid physics (Darcy-Weisbach); no BS EN 806 or BS 6891 tables are reproduced. Typical calls: {"medium":"gas","heat_input_kw_gross":30,"run_length_m":12,"fittings":{"elbows":5}} or {"medium":"water","service":"cold","outlets":[{"type":"bath"},{"type":"kitchen_sink"},{"type":"basin"},{"type":"wc"},{"type":"shower_mixer"}],"run_length_m":15,"supply_pressure_bar":2.5,"height_rise_m":3}.

Input parameters:

- `allowed_drop_mbar` (number): Gas only. Default 1 natural gas, 2.5 LPG.
- `design_flow_l_s` (number): Water only: design flow in litres a second, if known (overrides outlets).
- `fittings` (object): Count of fittings on the run. If left out, 30% is added to the length instead (or fittings_allowance_percent).
- `fittings_allowance_percent` (number): Length added for fittings when they are not counted. Default 30.
- `gas` (string): Gas only. Default natural_gas.
- `gas_flow_m3_h` (number): Gas only: gas flow, if already known.
- `heat_input_kw_gross` (number): Gas only: total gross heat input of every appliance this pipe feeds (data plate).
- `heat_input_kw_net` (number): Gas only: if only the net figure is known.
- `height_rise_m` (number): Water only: height gained from start to outlet (negative if it falls).
- `material` (string): Water: copper (default), plastic, mdpe. Gas: copper (default), steel, csst.
- `max_velocity_m_s` (number): Water only. Default 1.5.
- `medium` (string, required)
- `min_pressure_at_outlet_bar` (number): Water only: pressure needed at the end. Default 1.0 bar.
- `outlets` (array): Water only: outlets this pipe feeds.
- `pipe_size_mm` (number): Check only this nominal size.
- `run_length_m` (number, required): Measured pipe length, metres (from the meter for gas, from the stop tap or cylinder for water).
- `service` (string): Water only. Default cold.
- `simultaneous_outlets` (number): Water only: how many outlets run at once. Default: square root of the number of outlets, rounded.
- `supply_pressure_bar` (number): Water only: working pressure at the start of the run (measured with water flowing).
- `trade` (object): Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…
- `water_temp_c` (number): Water only. Default 10 cold, 60 hot.

### `size_heat_source` (~446 tokens)

Room by room heat loss, boiler and heat pump size

Works out the heat loss of each room (fabric U x A x delta T plus ventilation 0.33 x air changes x volume x delta T) and the total, then sizes a combi, system or regular boiler, or a heat pump, to the nearest common size. Combi sizing also checks the hot water load (flow x temperature rise). Give each room's type, size and its walls, windows, roof and floor with U values, or construction presets for indicative values. Returns per-room losses with every element's working, the total, the size, `status` (indicative when presets were used), `must_check` and sources. Typical call: {"heat_source":"heat_pump","outside_design_temp_c":-3,"rooms":[{"name":"Lounge","type":"living","floor_area_m2":20,"elements":[{"type":"wall","area_m2":7.8,"construction":"cavity_wall_unfilled"},{"type":"window","area_m2":1.8,"construction":"double_glazed_old"}]}]}.

Input parameters:

- `cylinder_litres` (number): System or regular boiler: cylinder size. Default 150.
- `heat_source` (string): Default combi_boiler.
- `hot_water_flow_l_min` (number): Combi: wanted hot water flow. Default 12.
- `hot_water_priority` (boolean): Default true (reheat load not added).
- `hot_water_temp_rise_c` (number): Combi: temperature rise. Default 35.
- `margin_percent` (number): Added to the heating load. Default 10 for boilers, 0 for heat pumps.
- `outside_design_temp_c` (number): Local outside design temperature. Default -3.
- `reheat_hours` (number): Wanted reheat time. Default 1.
- `rooms` (array, required): Up to 40 rooms.
- `trade` (object): Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…

### `size_radiators` (~287 tokens)

Radiator size per room, including at heat pump temperatures

For each room's heat loss, works out the rated (delta T 50) radiator output needed at the system's flow and return temperatures, using output = rated x (mean water to air difference / 50) ^ 1.3. Shows how far an existing radiator falls short, the water flow per radiator, indicative lengths by panel type, and with compare_flow_temp_c how much bigger radiators must be at a lower flow temperature (for example 70 C boiler to 45 C heat pump). Typical call: {"flow_temp_c":45,"rooms":[{"name":"Lounge","heat_loss_w":1500,"existing_rated_output_w":1800}],"compare_flow_temp_c":70}.

Input parameters:

- `compare_flow_temp_c` (number)
- `compare_return_temp_c` (number)
- `flow_temp_c` (number): Default 70.
- `radiator_exponent` (number): Default 1.3.
- `return_temp_c` (number): Default flow minus 10 (minus 5 at 55 C or lower).
- `rooms` (array, required)
- `trade` (object): Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…

### `check_notifiable_work` (~239 tokens)

Is this work notifiable, and who can do it?

For plumbing and heating jobs in England or Wales: does it need a Gas Safe registered engineer, an unvented (G3) qualified installer, building regulations notification (Approved Documents G, J, L and others) and a water company notice (Water Fittings Regulations, regulation 5)? Returns, per job, who can do it, the self-certification route (competent person scheme within 30 days, or building control before starting) and what to do next, including CO alarm and Boiler Plus rules. Typical call: {"nation":"england","work":["gas_boiler_replacement","unvented_cylinder_new"]}.

Input parameters:

- `nation` (string): Default england.
- `trade` (object): Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…
- `water_approved_contractor` (boolean): True if the installer is a water approved contractor (for example WaterSafe).
- `work` (array, required): One or more jobs.

### `check_gas_record` (~462 tokens)

Check a gas safety record or commissioning record before issuing it

Checks a filled landlord gas safety record (CP12) or a boiler commissioning record and lists errors and warnings: missing required fields, failed tightness, flue, ventilation or safety device checks, CO/CO2 ratio over the limits, gas rate off the rated input, meter pressure out of range, an unsafe appliance marked safe, and the correct next due date (keeping the anniversary for checks done up to 2 months early). Gas safety record fields: property_address, landlord_name, landlord_address, engineer_name, gas_safe_registration_number, engineer_licence_number, check_date, previous_record_expiry_date, next_check_due, engineer_signature, tightness_test_passed, emergency_control_accessible, meter_standing_pressure_mbar, meter_working_pressure_mbar, appliances[] {type, make, model, location, flue_type, flue_check_passed, ventilation_satisfactory, safety_devices_ok, co_ppm, co2_percent, co_co2_ratio, rated_heat_input_kw_gross, measured_gas_rate_m3_h, inlet_working_pressure_mbar, status (safe, ncs, at_risk, immediately_dangerous), safe_to_use, action_taken}. Commissioning fields: property_address, engineer_name, commissioning_date, boiler_type, system_flushed, inhibitor_added, inhibitor_name, filter_fitted, water_hardness_ppm, scale_reducer_fitted, condensate_external_pipe_mm, controls_time_and_temperature, combi_extra_measure, co_alarm_fitted, building_regs_notified, dhw_flow_l_min, dhw_temp_rise_c, appliances[] {make, model, serial_number, co_ppm, co2_percent, min_rate {co_ppm, co2_percent}, rated_heat_input_kw_gross, measured_gas_rate_m3_h}. Up to 30 appliances.

Input parameters:

- `record` (object, required): The filled fields (see the description).
- `record_type` (string, required)
- `trade` (object): Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…

### `emergency_triage` (~342 tokens)

Emergency triage for leaks, bursts, no heat, gas smell or CO alarm

For a homeowner reporting a problem: the safe first steps to do now, what not to do, who to call first (the gas emergency service 0800 111 999 for a gas smell or CO alarm), whether it is a real emergency, and an `urgency` value of routine, soon or emergency that matches Nero Work's three job speeds, raised for water near electrics, a bulging ceiling, a vulnerable person in the cold, or water that cannot be stopped. Also returns `nero_work_job` (urgency, category, summary) ready to post. Typical call: {"situation":"no_heat","vulnerable_people":true,"outside_temp_c":2,"other_heating_available":false}.

Input parameters:

- `ceiling_bulging` (boolean)
- `nation` (string): Changes the gas emergency number for Northern Ireland.
- `only_toilet` (boolean)
- `other_heating_available` (boolean)
- `outside_temp_c` (number)
- `pipe_split` (boolean)
- `sewage_inside` (boolean)
- `situation` (string, required)
- `trade` (object): Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…
- `vulnerable_people` (boolean): Elderly, very young, disabled or medically vulnerable person in the home.
- `water_near_electrics` (boolean)
- `water_stopped` (boolean): Has turning off the stop tap or valve stopped the water?

### `trade_profile` (~194 tokens)

Check the plumber or heating engineer's business details

Checks the business's own details (Nero Trade Profile v1: trading name, Companies House number, registration scheme and number, postcode, contact) and returns them cleaned, with a stable `nero_trade_ref` computed from the scheme registration (licence_body gas_safe plus the Gas Safe registration number) or the company number. The same shape and reference as Spark Pack, so one business keeps one reference across trades. The same object, given as `trade` to the other tools, prefills records. Flow Pack stores nothing. The same profile and reference can later be used to sign the business into Nero Work, the agent job exchange for trades.

Input parameters:

- `trade` (object, required): Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not…

## Diagnostics

Captured diagnostic sections: TLS, DNSSEC, Authorisation, Transports. The full working is on the page: https://verifymcp.io/servers/nero-engine-flow-pack/flow-pack#diagnostics

## Score history

- 2026-11-21: 64
- 2026-11-20: 64
- 2026-11-19: 63
- 2026-11-18: 63
- 2026-11-17: 62
- 2026-11-16: 62
- 2026-11-15: 62
- 2026-11-14: 61
- 2026-11-13: 61

## Common questions

### What is the Flow Pack MCP server?

Flow Pack is an MCP server listed in the public MCP registry as io.github.Nero-Engine/flow-pack. Pipe sizing, heat loss, gas record checks and emergency triage for UK plumbers' AI assistants. This page covers its hosted endpoint (https://flow-pack.nerolabs.workers.dev/mcp).

### Is the Flow Pack MCP server safe to use?

Flow Pack scores 64 out of 100 on VerifyMCP. That is a record of what we were able to check automatically, not an endorsement. The category breakdown on this page shows every signal behind the number, including the ones we could not confirm.

### What tools does the Flow Pack MCP server expose?

Flow Pack exposes 8 tools: list_capabilities, size_pipe, size_heat_source, size_radiators, check_notifiable_work, and 3 more. Their descriptions and schemas cost roughly 2,782 tokens of context every time the server is loaded.

### Does the Flow Pack MCP server require authentication?

No. We connected to Flow Pack without credentials and it answered, so anything it exposes is reachable by anyone who knows the address.

### Is the Flow Pack MCP server still maintained?

Flow Pack is still listed as active in the MCP registry. We last reached this channel on 21 November 2026. Those dates come from our own scans of the registry and the channel itself, not from anything the publisher announced.

### What did VerifyMCP test on the Flow Pack MCP server?

VerifyMCP ran 12 checks on Flow Pack, covering TLS certificate, Authorization, HSTS header, DNSSEC and 8 more. One item could not be completed, a gap on our side rather than a finding about Flow Pack: HTTPS. Supply Chain Security and Provenance & Transparency do not apply to a hosted endpoint, so they were not tested. The score does not measure everything, and the scoring documentation lists what it leaves out.

## Links

- Remote endpoint: https://flow-pack.nerolabs.workers.dev/mcp
- Repository: https://github.com/Nero-Engine/flow-pack-mcp
- Website: https://flow-pack.nerolabs.workers.dev/docs
- Changelog RSS feed: https://verifymcp.io/servers/nero-engine-flow-pack/flow-pack.xml
- Changelog JSON feed: https://verifymcp.io/servers/nero-engine-flow-pack/flow-pack/changelog.json
- Trust report (JSON): https://verifymcp.io/servers/nero-engine-flow-pack/flow-pack.json
- HTML version of this page: https://verifymcp.io/servers/nero-engine-flow-pack/flow-pack