Skip to content
verify mcp Beta VerifyMCP is currently in beta. If you notice any issues, get in touch and we’ll put it right.

Whatic IC Datasheets

REMOTE · WHATIC.IO

IC datasheet search: parametric part finding, spec lookup, price comparison — grounded in real PDFs.

Available components

0 this week 79 Trust /100

Last scanned (22 hours ago)

Scores higher than 74% of remote servers

Reachable. Last reached 21 Nov 2026.

Category IoT and Hardware

Trust breakdown (7 categories)

How this component scores in each security and reliability category. Every signal is checked automatically against the live server, and we only credit what we can confirm. How we score → Why this is hard to score →

Endpoint Security74
  • The endpoint's TLS certificate is valid, in date, and uses a strong key. View diagnostics → Pass
  • No authorisation is required to call this server. Nothing on it is marked destructive, but we can't show that an anonymous caller can only read: full credit needs the server to list at least one tool and every tool to be verifiably read-only. We use a best-effort check of tool names and descriptions to tell read-only tools from tools that change things, so some genuinely read-only tools may not get full credit. Names that start with a read verb (get, list, read, search and similar) and accurate readOnlyHint annotations help. Meet that to earn full credit, or require authorisation. See how to fix → View diagnostics → Partial
  • HTTPS is enforced; there's no plaintext access path. View diagnostics → Pass
  • HSTS check failed: the Strict-Transport-Security header is absent. See how to fix → View diagnostics → Fail
  • DNSSEC check failed: this domain isn't protected by DNSSEC. See how to fix → View diagnostics → Fail
Transport & Reachability100
Schema Quality & AI Usability42
  • 0% of prompts and resources have a non-trivial description (not blank, and not just the item's name).Fail
  • AI-judged instruction clarity (good).Pass
  • Context-footprint check failed: tool/resource definitions use about 1432 tokens (~179/item across 8 items; 7 tools + 1 resources), over budget; trim descriptions and params. See how to fix → Fail
  • Usage-examples check failed: none of the tools include examples. See how to fix → Fail
Stability & Change Management100
  • No destabilizing schema changes in the last 30 days.Pass
Tool Coverage100
  • 100% of tools have a non-trivial description (not blank, and not just the tool's name).Pass
  • 100% of tool parameters carry a description.Pass
  • Structured output schemas are declared (86% of tools); any adoption earns full credit.Pass
Tool Safety100
  • No prompt-injection markers were found in the server instructions, tool names or descriptions we captured.Pass
  • We read all 7 captured tool definition(s), and no name or description among them implies an irreversible operation.Pass
  • An AI judge read all 9 captured unit(s) of tool text and found none that tries to manipulate the model reading it.Pass
Capabilities100
  • Implements a supported MCP spec version (2025-11-25); the latest is 2026-07-28.Pass
What we tested

Checks we ran (13)

  • TLS certificate
  • Authorization
  • HTTPS
  • HSTS header
  • DNSSEC
  • Transport
  • Schema quality
  • Stability
  • Tool coverage
  • Injection markers
  • Destructive annotations
  • Judged manipulation
  • MCP protocol

Does not apply to this hosted endpoint (2)

  • Supply Chain SecurityScored on package channels only. This is a hosted endpoint, so there is nothing to install or inspect.
  • Provenance & TransparencyScored on package channels only. This is a hosted endpoint, so there is nothing to install or inspect.

The score does not measure everything. What the score does not measure →

Changelog

Every change we have recorded for this component, newest first. Security-relevant changes are always shown. ▲ marks a change for the better, ▼ a change for the worse; unmarked changes are neutral.

  • 11 Nov 26 0
    • Stability: 0.97 → pass security
  • 10 Nov 26 0
    • Stability: pass → 0.97 functional
  • 9 Nov 26 0
    • Stability: 0.97 → pass security
  • 8 Nov 26 0
    • Stability: pass → 0.97 functional
  • 7 Nov 26 0
    • Tool “find_parts” rewrote its description, which is the text the model reads security
    • Tool “search” rewrote its description, which is the text the model reads security
    • Schema quality: 161 → 179 ▼ functional
    • “find_parts” added an optional parameter “cluster” cosmetic
    • “search” reworded the description of “scope” cosmetic
  • 6 Nov 26 0
    • We updated how we score, so this day's move reflects our rubric, not a change to the server See what changed → functional
  • 23 Oct 26 79
    • Server version: 1.28.1 → 1.30.0 functional
  • 28 Sept 26 0
    • We updated how we score, so this day's move reflects our rubric, not a change to the server See what changed → functional
Diagnostics

Diagnostic detail from the automated scan of this channel: what the scanner observed at each step, so you can see exactly where a check passed or failed. It is informational only and never changes the trust score.

Captured 21 Nov 2026 · Probed https://whatic.io/mcp

TLS valid

Negotiated TLS 1.3 with TLS_AES_128_GCM_SHA256 .

Subject Issuer Valid from Valid until Key Signature Serial
CN=whatic.io CN=YE2,O=Let's Encrypt,C=US 26 Sept 2026 25 Dec 2026 ECDSA 256 ECDSA-SHA384 6f3ec7b88f6a90808acc777f3c5ce3ee47b
SANs: whatic.io
CN=YE2,O=Let's Encrypt,C=US (CA) CN=Root YE,O=ISRG,C=US 3 Sept 2025 2 Sept 2028 ECDSA 384 ECDSA-SHA384 4df3b15dd6c0784c507cd37b58e6f115
CN=Root YE,O=ISRG,C=US (CA) CN=ISRG Root X2,O=Internet Security Research Group,C=US 13 May 2026 2 Sept 2032 ECDSA 384 ECDSA-SHA384 872165fc34b6e5fba8add5b3705fb53a
CN=ISRG Root X2,O=Internet Security Research Group,C=US (CA) CN=ISRG Root X1,O=Internet Security Research Group,C=US 13 May 2026 2 Sept 2032 ECDSA 384 SHA256-RSA 6c8f1dc727c7117f7baf853ac980f9cd

Background: What to check on a remote MCP endpoint →

DNSSEC insecure

Validation of whatic.io. — Not signed

Zone DS Keys Algorithms Outcome
. Trust anchor 20326, 38696 8, 8 Verified
io. DS published 38690 8 Verified
whatic.io. No DS Unsigned (proven) parent-signed NSEC/NSEC3 proves an unsigned delegation
Authentication No authorisation required

The endpoint answered without asking for a token. Anyone who knows the URL can reach it.

Result No authorisation required
HTTP status 200

Background: How OAuth 2.1 works in the 2026 MCP spec →

Transports 2 probes
Transport URL Outcome Status Location
streamable-http https://whatic.io/mcp Verified 200
http (plaintext) http://whatic.io/mcp HTTPS enforced 301 https://whatic.io/mcp
MCP tools · 7 exposed · ~1,073 tokens

The tools this component advertises to a client, with an estimated token cost for each. Expand a tool to see its parameters and schema. The per-tool counts are indicative and are not scored directly; the schema's total context footprint is one signal in Schema Quality & AI Usability. A tool's description is untrusted text the model reads on every call, which is what makes this list a security surface and not just an inventory: how tool poisoning works →

Tool Tokens
compare_parts ~64

Relative price tier, stock posture, and library class for a set of IC part numbers (a ranking from a distributor snapshot, not a live quote).

NameTypeReqDescription
partsarrayyesTwo or more IC part numbers to rank relatively; needs >=2 priced parts for a verdict.

Structured output declared, but exposes no named fields.

No examples provided.

find_parts ~298

Shortlist IC part numbers by parametric spec constraints, ranked by how many constraints each part satisfies, then by headroom past those thresholds, and spread across device families. Each constraint is {canonical, op: gte|lte|eq|range, value, unit?}. Returns per-constraint pass/fail/unknown, plus `matched` (parts meeting EVERY constraint), `ranked` (all parts scored, partial matches included) and `returned` (parts in this response). `truncated` means some qualifying parts are not on this page. When `matched` is 0 every result is a partial match. Pass `cluster` (e.g. 'MCU', 'LDO') to search within one component class. `canonical` MUST be one of the exact (case-sensitive) names enumerated in this tool's inputSchema, also readable as the whatic://parametric/canonicals resource.

NameTypeReqDescription
cluster––Optional component class to search within, e.g. 'MCU', 'LDO', 'Op-Amp', 'DC-DC-Converter'. Without it every part reporting the constrained specs competes, so an MCU standby-current query ranks LDOs f…
constraintsarrayyesSpec constraints; a part is ranked by how many it satisfies.
top_kinteger–Maximum number of parts to return, best first.

Structured output declared, but exposes no named fields.

No examples provided.

get_image ~124

Fetch datasheet figure images (PNG/JPEG) for opaque `ref` tokens obtained from search/lookup/get_segments. Returns each image plus its caption/description/page metadata. Only `type='image'` segments have image data; a ref that is not one comes back as an error record whose `available_images` lists the document's figures nearest that ref's page and section, closest first.

NameTypeReqDescription
refsarrayyesOpaque `ref` tokens (from search/lookup/get_segments) of image segments; non-image segments return an error record.

No output schema declared.

No examples provided.

get_segments ~54

Expand opaque `ref` tokens (from search/lookup) into full datasheet segment content.

NameTypeReqDescription
refsarrayyesOpaque `ref` tokens from search/lookup hit records, to expand into full segment content.

Structured output declared, but exposes no named fields.

No examples provided.

get_specs ~177

Read canonical extracted specs (min/typ/max, unit, conditions) for known IC part numbers from a pre-extracted parametric index — not from datasheet text. This is the cheapest and most precise source for numeric parameters where it has coverage. Optionally restrict to specific canonical parameter names. A part absent from `results` (with a "No specs found" warning) means no index coverage, not that the datasheet lacks the parameter — fall back to `lookup` for that part.

NameTypeReqDescription
canonicals––Optional: restrict to these canonical parameter names; omit to return all available specs.
part_numbersarrayyesExact IC part numbers / MPNs, e.g. ['NE5532', 'LM358']. Family fallback is applied (e.g. TL084CDT -> TL084C).

Structured output declared, but exposes no named fields.

No examples provided.

lookup ~109

One-shot spec/section retrieval: full content of the most relevant datasheet segments for one or more parts (fuses search+get_segments). Already groups results per part (via `parts`), so prefer `lookup` over `search` when you know the part(s).

NameTypeReqDescription
parts––Part numbers to scope and group the retrieval by; results are returned per part.
querystringyesWhat to retrieve, e.g. 'supply voltage' or 'absolute maximum ratings'.

Structured output declared, but exposes no named fields.

No examples provided.

search ~247

Search the datasheet corpus; returns hit records (metadata + snippet, each with an opaque `ref`). Pass a ref list to `get_segments` for full content. If you already know the part number(s), prefer `lookup` — it fuses this search with `get_segments` in one call and groups full content per part. Use `search` when the part is unknown, or to triage snippets before pulling full content. For part-specific queries, pass scope='device:<MPN>' (e.g. scope='device:NE5532') to restrict hits to that part and avoid cross-part contamination. Other scopes: 'doc:<doc_id>', 'cluster:<name>', 'general'.

NameTypeReqDescription
kinteger–Maximum number of hit records to return.
qstringyesFree-text query, e.g. 'input voltage noise density'.
scope––Optional filter restricting hits: 'device:<MPN>[,<MPN>]' (e.g. 'device:NE5532') for specific parts, 'doc:<doc_id>' for one source document, 'cluster:<name>' for a part family, or 'general' for everyt…

Structured output declared, but exposes no named fields.

No examples provided.

Install

How do I install the Whatic IC Datasheets MCP server?

Whatic IC Datasheets is a hosted endpoint at https://whatic.io/mcp, so there is nothing to install locally. Ready-made configuration for Claude, Cursor, VS Code, Codex and 5 more is on this page, copied from each client's own documentation.

remote · whatic.io

# add to Claude Code
claude mcp add --transport http io-whatic-datasheets 'https://whatic.io/mcp'
Common questions

What is the Whatic IC Datasheets MCP server?

Whatic IC Datasheets is an MCP server listed in the public MCP registry as io.whatic/datasheets. IC datasheet search: parametric part finding, spec lookup, price comparison, grounded in real PDFs. This page covers its hosted endpoint (https://whatic.io/mcp).

Is the Whatic IC Datasheets MCP server safe to use?

Whatic IC Datasheets scores 79 out of 100 on VerifyMCP. That is a record of what we were able to check automatically, not an endorsement. The category breakdown on this page shows every signal behind the number, including the ones we could not confirm.

What tools does the Whatic IC Datasheets MCP server expose?

Whatic IC Datasheets exposes 7 tools: find_parts, get_specs, compare_parts, search, lookup, and 2 more. Their descriptions and schemas cost roughly 1,073 tokens of context every time the server is loaded.

Does the Whatic IC Datasheets MCP server require authentication?

No. We connected to Whatic IC Datasheets without credentials and it answered, so anything it exposes is reachable by anyone who knows the address.

Is the Whatic IC Datasheets MCP server still maintained?

Whatic IC Datasheets is still listed as active in the MCP registry. We last reached this channel on 21 November 2026. Those dates come from our own scans of the registry and the channel itself, not from anything the publisher announced.

What did VerifyMCP test on the Whatic IC Datasheets MCP server?

VerifyMCP ran 13 checks on Whatic IC Datasheets, covering TLS certificate, Authorization, HTTPS, HSTS header and 9 more. Supply Chain Security and Provenance & Transparency do not apply to a hosted endpoint, so they were not tested. The score does not measure everything, and the scoring documentation lists what it leaves out.