Enervia Power — Solar & BESS sizing
REMOTE · WWW.ENERVIAPOWER.COM
Size solar, backup power and LiFePO4 battery systems for Iran; product picks and Persian guides.
Available components
Last scanned (2 hours ago)
Scores higher than 87% of remote servers
Reachable. Last reached 5 Nov 2026.
Category IoT and Hardware
How this component scores in each security and reliability category. Every signal is checked automatically against the live server, and we only credit what we can confirm. How we score → Why this is hard to score →
Endpoint Security80
- The endpoint's TLS certificate is valid, in date, and uses a strong key. View diagnostics → Pass
- No authorisation is required to call this server. Every tool declares its destructiveHint and none is destructive, so open access doesn't expose one. See how to fix → View diagnostics → Partial
- HTTPS is enforced; there's no plaintext access path. View diagnostics → Pass
- The HSTS (Strict-Transport-Security) header is present. View diagnostics → Pass
- DNSSEC check failed: this domain isn't protected by DNSSEC. See how to fix → View diagnostics → Fail
Transport & Reachability100
- Verified streamable-http transport via a live MCP handshake. View diagnostics → Pass
Schema Quality & AI Usability64
- AI-judged instruction clarity (good).Pass
- Context-footprint check failed: tool/resource definitions use about 968 tokens (~161/item across 6 items; 6 tools + 0 resources), over budget; trim descriptions and params. See how to fix → Fail
- Usage-examples check failed: none of the tools include examples. See how to fix → Fail
Stability & Change Management80
- Stability observed for 24 of 30 days with no destabilising changes; credit accrues until the full window elapses.Partial
Tool Coverage100
- 100% of tools have a non-trivial description (not blank, and not just the tool's name).Pass
- 100% of tool parameters carry a description.Pass
Tool Safety100
- No prompt-injection markers were found in the server instructions, tool names or descriptions we captured.Pass
- We read all 6 captured tool definition(s), and no name or description among them implies an irreversible operation.Pass
- An AI judge read all 7 captured unit(s) of tool text and found none that tries to manipulate the model reading it.Pass
Capabilities100
- Implements a supported MCP spec version (2025-11-25); the latest is 2026-07-28.Pass
Every change we have recorded for this component, newest first. Security-relevant changes are always shown. ▲ marks a change for the better, ▼ a change for the worse; unmarked changes are neutral.
- 5 Nov 26 +1
No change was recorded against any check on this day. Stability & Change Management went from 77 to 80. That category is still filling its 30-day observation window: 23 days of observed history at the previous scan, 24 at this one. The score rises as the window fills, whether or not the server changes.
- 3 Nov 26 +1
No change was recorded against any check on this day. Stability & Change Management went from 70 to 73. That category is still filling its 30-day observation window: 21 days of observed history at the previous scan, 22 at this one. The score rises as the window fills, whether or not the server changes.
- 1 Nov 26 +1
No change was recorded against any check on this day. Stability & Change Management went from 63 to 67. That category is still filling its 30-day observation window: 19 days of observed history at the previous scan, 20 at this one. The score rises as the window fills, whether or not the server changes.
- 29 Oct 26 +1
No change was recorded against any check on this day. Stability & Change Management went from 53 to 57. That category is still filling its 30-day observation window: 16 days of observed history at the previous scan, 17 at this one. The score rises as the window fills, whether or not the server changes.
- 27 Oct 26 +1
No change was recorded against any check on this day. Stability & Change Management went from 47 to 50. That category is still filling its 30-day observation window: 14 days of observed history at the previous scan, 15 at this one. The score rises as the window fills, whether or not the server changes.
- 25 Oct 26 +1
No change was recorded against any check on this day. Stability & Change Management went from 40 to 43. That category is still filling its 30-day observation window: 12 days of observed history at the previous scan, 13 at this one. The score rises as the window fills, whether or not the server changes.
- 23 Oct 26 +1
No change was recorded against any check on this day. Stability & Change Management went from 33 to 37. That category is still filling its 30-day observation window: 10 days of observed history at the previous scan, 11 at this one. The score rises as the window fills, whether or not the server changes.
- 21 Oct 26 +1
No change was recorded against any check on this day. Stability & Change Management went from 27 to 30. That category is still filling its 30-day observation window: 8 days of observed history at the previous scan, 9 at this one. The score rises as the window fills, whether or not the server changes.
Diagnostic detail from the automated scan of this channel: what the scanner observed at each step, so you can see exactly where a check passed or failed. It is informational only and never changes the trust score.
Captured 5 Nov 2026 · Probed https://www.enerviapower.com/api/mcp
TLS valid
Negotiated TLS 1.3 with TLS_AES_128_GCM_SHA256 .
| Subject | Issuer | Valid from | Valid until | Key | Signature | Serial |
|---|---|---|---|---|---|---|
| CN=*.enerviapower.com | CN=YR2,O=Let's Encrypt,C=US | 25 Sept 2026 | 24 Dec 2026 | RSA 2048 | SHA256-RSA | 571a41d94b98ea39d13ba59a5548b3651b3 |
| SANs: *.enerviapower.com, enerviapower.com | ||||||
| CN=YR2,O=Let's Encrypt,C=US (CA) | CN=Root YR,O=ISRG,C=US | 3 Sept 2025 | 2 Sept 2028 | RSA 2048 | SHA256-RSA | 4ebd24947e24d394802d84a52fd5b319 |
| CN=Root YR,O=ISRG,C=US (CA) | CN=ISRG Root X1,O=Internet Security Research Group,C=US | 13 May 2026 | 2 Sept 2032 | RSA 4096 | SHA256-RSA | f24b6d17f9d9ad7cb1c9fea78782699f |
Background: What to check on a remote MCP endpoint →
DNSSEC insecure
Validation of www.enerviapower.com. — Not signed
| Zone | DS | Keys | Algorithms | Outcome |
|---|---|---|---|---|
| . | trust_anchor | 20326, 38696 | 8, 8 | Verified |
| com. | present | 19718 | 13 | Verified |
| enerviapower.com. | absent | Unsigned (proven) parent-signed NSEC/NSEC3 proves an unsigned delegation |
Authentication No authorisation required
The endpoint answered without asking for a token. Anyone who knows the URL can reach it.
| Result | No authorisation required |
|---|---|
| HTTP status | 200 |
| Header | Value |
|---|---|
| strict-transport-security | max-age=63072000 |
| content-security-policy | default-src 'self'; script-src 'self' 'unsafe-inline' https://www.googletagmanager.com https://tagassistant.google.com https://*.yektanet.com; style-src 'self' 'unsafe-inline'; font-src 'self'; img-src 'self' data: https://www.googletagmanager.com https://*.google-analytics.com https://tagassistant.google.com https://server.arcgisonline.com https://services.arcgisonline.com https://*.yektanet.com; connect-src 'self' https://n8n-production-7edf.up.railway.app https://www.googletagmanager.com https://*.google-analytics.com https://*.analytics.google.com https://tagassistant.google.com https://*.yektanet.com; frame-src https://calendar.google.com https://www.googletagmanager.com https://*.yektanet.com; frame-ancestors 'self'; base-uri 'self'; form-action 'self' |
| x-content-type-options | nosniff |
| x-frame-options | SAMEORIGIN |
| referrer-policy | strict-origin-when-cross-origin |
| permissions-policy | camera=(), microphone=(), geolocation=(self) |
Background: How OAuth 2.1 works in the 2026 MCP spec →
Transports 2 probes
| Transport | URL | Outcome | Status | Location |
|---|---|---|---|---|
| streamable-http | https://www.enerviapower.com/api/mcp | Verified | 200 | |
| http (plaintext) | http://www.enerviapower.com/api/mcp | HTTPS enforced | 308 | https://www.enerviapower.com/api/mcp |
The tools this component advertises to a client, with an estimated token cost for each. Expand a tool to see its parameters and schema. The per-tool counts are indicative and are not scored directly; the schema's total context footprint is one signal in Schema Quality & AI Usability. A tool's description is untrusted text the model reads on every call, which is what makes this list a security surface and not just an inventory: how tool poisoning works →
calculate_bess_system ~322
محاسبه ظرفیت باتری، توان اینورتر و تعداد پنل خورشیدی موردنیاز بر اساس لیست مصارف یا پیک بار. Calculate required battery capacity, inverter power and solar panel count for a backup or off-grid system.
| Name | Type | Req | Description |
|---|---|---|---|
| appliances | array | – | لیست مصارف برقی |
| autonomyDays | number | – | روزهای خودکفایی (حالت offgrid) |
| backupHours | number | – | ساعات نیاز به بکآپ (حالت backup) |
| concurrencyPct | number | – | ضریب همزمانی مصرف ٪ (حالت backup) |
| mode | string | – | backup = برق اضطراری؛ offgrid = سیستم خورشیدی مستقل |
| panelEff | number | – | راندمان سیستم ٪ (حالت offgrid؛ ۲۰٪ تلفات سیستم. حاشیه شارژ دوباره باتری و افت پنل جداگانه اعمال میشود) |
| panelW | number | – | توان هر پنل خورشیدی (وات)؛ پنلهای جینکو/ترینا ۶۲۵ تا ۷۴۰ وات |
| peakKW | number | – | حداکثر توان مصرفی (kW). اگر appliances داده شود، خودکار محاسبه میشود |
| sunHours | number | – | ساعات آفتابی موثر PSH در ماه کمتابش (حالت offgrid؛ تهران دیماه ≈ 4) |
| template | string | – | بهجای appliances میتوان یک الگوی آماده انتخاب کرد |
No output schema declared.
No examples provided.
get_contact_info ~60
نشانی، تلفن، ساعات کاری و لینک ثبت درخواست خدمات (نصب، بازدید، تعمیر، گارانتی) انرویا پاور. EnerviaPower addresses, phone numbers, opening hours and the service-request / warranty URLs.
Input schema present but exposes no named parameters.
No output schema declared.
No examples provided.
list_load_templates ~47
فهرست الگوهای آماده مصرف (آپارتمان، ویلا، دفتر، فروشگاه) به همراه دستگاهها. List the built-in load profiles the calculator can start from.
Input schema present but exposes no named parameters.
No output schema declared.
No examples provided.
list_products ~54
کاتالوگ محصولات انرویا پاور (ذخیرهسازها، اینورترها، نیروگاههای قابل حمل). Return the EnerviaPower product catalog (storage, inverters, portable).
Input schema present but exposes no named parameters.
No output schema declared.
No examples provided.
search_articles ~125
جستوجو در مقالههای آموزشی انرویا پاور (برق خورشیدی، باتری LiFePO4، برق اضطراری، اینورتر). Search the EnerviaPower knowledge base (Persian articles on solar, LiFePO4 batteries, backup power, inverters). Returns title, URL, excerpt and date; an empty query returns the newest articles.
| Name | Type | Req | Description |
|---|---|---|---|
| limit | number | – | حداکثر تعداد نتیجه (۱ تا ۲۰) |
| query | string | – | عبارت جستوجو (فارسی یا انگلیسی) |
No output schema declared.
No examples provided.
suggest_products ~325
بر اساس نیاز محاسبهشده، محصولات مناسب انرویا پاور (اینورتر، باتری، پنل) را پیشنهاد میدهد. Suggest matching EnerviaPower products for the calculated system size. Accepts the same inputs as calculate_bess_system.
| Name | Type | Req | Description |
|---|---|---|---|
| appliances | array | – | لیست مصارف برقی |
| autonomyDays | number | – | روزهای خودکفایی (حالت offgrid) |
| backupHours | number | – | ساعات نیاز به بکآپ (حالت backup) |
| concurrencyPct | number | – | ضریب همزمانی مصرف ٪ (حالت backup) |
| mode | string | – | backup = برق اضطراری؛ offgrid = سیستم خورشیدی مستقل |
| panelEff | number | – | راندمان سیستم ٪ (حالت offgrid؛ ۲۰٪ تلفات سیستم. حاشیه شارژ دوباره باتری و افت پنل جداگانه اعمال میشود) |
| panelW | number | – | توان هر پنل خورشیدی (وات)؛ پنلهای جینکو/ترینا ۶۲۵ تا ۷۴۰ وات |
| peakKW | number | – | حداکثر توان مصرفی (kW). اگر appliances داده شود، خودکار محاسبه میشود |
| sunHours | number | – | ساعات آفتابی موثر PSH در ماه کمتابش (حالت offgrid؛ تهران دیماه ≈ 4) |
| template | string | – | بهجای appliances میتوان یک الگوی آماده انتخاب کرد |
No output schema declared.
No examples provided.
How do I install the Enervia Power — Solar & BESS sizing MCP server?
Enervia Power — Solar & BESS sizing is a hosted endpoint at https://www.enerviapower.com/api/mcp, so there is nothing to install locally. Ready-made configuration for Claude, Cursor, VS Code, Codex and 5 more is on this page, copied from each client's own documentation.
remote · www.enerviapower.com
claude mcp add --transport http com-enerviapower-bess 'https://www.enerviapower.com/api/mcp'
What is the Enervia Power — Solar & BESS sizing MCP server?
Enervia Power — Solar & BESS sizing is an MCP server listed in the public MCP registry as com.enerviapower/bess. Size solar, backup power and LiFePO4 battery systems for Iran; product picks and Persian guides. This page covers its hosted endpoint (https://www.enerviapower.com/api/mcp).
Is the Enervia Power — Solar & BESS sizing MCP server safe to use?
Enervia Power — Solar & BESS sizing scores 83 out of 100 on VerifyMCP. That is a record of what we were able to check automatically, not an endorsement. The category breakdown on this page shows every signal behind the number, including the ones we could not confirm.
What tools does the Enervia Power — Solar & BESS sizing MCP server expose?
Enervia Power — Solar & BESS sizing exposes 6 tools: calculate_bess_system, suggest_products, list_load_templates, list_products, search_articles, get_contact_info. Their descriptions and schemas cost roughly 933 tokens of context every time the server is loaded.
Does the Enervia Power — Solar & BESS sizing MCP server require authentication?
No. We connected to Enervia Power — Solar & BESS sizing without credentials and it answered, so anything it exposes is reachable by anyone who knows the address.
Is the Enervia Power — Solar & BESS sizing MCP server still maintained?
Enervia Power — Solar & BESS sizing is still listed as active in the MCP registry. We last reached this channel on 5 November 2026. Those dates come from our own scans of the registry and the channel itself, not from anything the publisher announced.