# Enervia Power — Solar & BESS sizing (remote · www.enerviapower.com)

Size solar, backup power and LiFePO4 battery systems for Iran; product picks and Persian guides.

- Trust score: 83/100 (high trust)
- Change this week: +3
- Registry status: active
- Liveness: live
- Owner verified: no
- Last scored: 2026-11-05

## Components

- remote · `www.enerviapower.com`: 83/100 (this document), [markdown](https://verifymcp.io/servers/com-enerviapower-bess/api-mcp.md), [page](https://verifymcp.io/servers/com-enerviapower-bess/api-mcp)

## Channel facts

- Endpoint: `https://www.enerviapower.com/api/mcp`
- Transports: `streamable-http`
- Auth: `none`
- Version: `1.1.0`

## Trust breakdown

How this component scores in each security and reliability category. Every signal is checked automatically against the live server, and we only credit what we can confirm. Scores are 0–100 per category. Scoring method: https://verifymcp.io/docs/scoring (what has changed: https://verifymcp.io/docs/scoring/changelog)

Scored 2026-11-05.

- **Endpoint Security**: 80/100
  - The endpoint's TLS certificate is valid, in date, and uses a strong key.
  - No authorisation is required to call this server. Every tool declares its destructiveHint and none is destructive, so open access doesn't expose one.
  - HTTPS is enforced; there's no plaintext access path.
  - The HSTS (Strict-Transport-Security) header is present.
  - DNSSEC check failed: this domain isn't protected by DNSSEC.
- **Transport & Reachability**: 100/100
  - Verified streamable-http transport via a live MCP handshake.
- **Schema Quality & AI Usability**: 64/100
  - AI-judged instruction clarity (good).
  - Context-footprint check failed: tool/resource definitions use about 968 tokens (~161/item across 6 items; 6 tools + 0 resources), over budget; trim descriptions and params.
  - Usage-examples check failed: none of the tools include examples.
- **Stability & Change Management**: 80/100
  - Stability observed for 24 of 30 days with no destabilising changes; credit accrues until the full window elapses.
- **Tool Coverage**: 100/100
  - 100% of tools have a non-trivial description (not blank, and not just the tool's name).
  - 100% of tool parameters carry a description.
- **Tool Safety**: 100/100
  - No prompt-injection markers were found in the server instructions, tool names or descriptions we captured.
  - We read all 6 captured tool definition(s), and no name or description among them implies an irreversible operation.
  - An AI judge read all 7 captured unit(s) of tool text and found none that tries to manipulate the model reading it.
- **Capabilities**: 100/100
  - Implements a supported MCP spec version (2025-11-25); the latest is 2026-07-28.

## Install

### How do I install the Enervia Power — Solar & BESS sizing MCP server?

Enervia Power — Solar & BESS sizing is a hosted endpoint at https://www.enerviapower.com/api/mcp, so there is nothing to install locally. Ready-made configuration for Claude, Cursor, VS Code, Codex and 5 more is on this page, copied from each client's own documentation.

### Claude

```bash
claude mcp add --transport http com-enerviapower-bess 'https://www.enerviapower.com/api/mcp'
```

### Cursor

```json
{
  "mcpServers": {
    "com-enerviapower-bess": {
      "url": "https://www.enerviapower.com/api/mcp"
    }
  }
}
```

### VS Code

```json
{
  "servers": {
    "com-enerviapower-bess": {
      "type": "http",
      "url": "https://www.enerviapower.com/api/mcp"
    }
  }
}
```

### Codex

```toml
[mcp_servers.com-enerviapower-bess]
url = "https://www.enerviapower.com/api/mcp"
```

### opencode

```json
{
  "$schema": "https://opencode.ai/config.json",
  "mcp": {
    "com-enerviapower-bess": {
      "type": "remote",
      "url": "https://www.enerviapower.com/api/mcp",
      "enabled": true
    }
  }
}
```

### OpenClaw

```bash
openclaw mcp add com-enerviapower-bess --url 'https://www.enerviapower.com/api/mcp' --transport streamable-http
```

### Hermes

```yaml
mcp_servers:
  com-enerviapower-bess:
    url: "https://www.enerviapower.com/api/mcp"
```

### Netclaw

```json
{
  "McpServers": {
    "com-enerviapower-bess": {
      "Transport": "http",
      "Url": "https://www.enerviapower.com/api/mcp"
    }
  }
}
```

### Vellum

```bash
assistant mcp add com-enerviapower-bess -t streamable-http -u 'https://www.enerviapower.com/api/mcp'
```

### Other

```json
{
  "mcpServers": {
    "com-enerviapower-bess": {
      "type": "http",
      "url": "https://www.enerviapower.com/api/mcp"
    }
  }
}
```

The mcpServers block is a cross-client convention. Remote transports vary, so check your client's docs.

## Changelog

Every change recorded for this component, newest first. Days that predate change tracking, or that we cannot explain, say so: "we were watching and nothing happened" and "we were not watching" are different claims.

### 2026-11-05 (score 83, +1)

No change was recorded against any check on this day. Stability & Change Management went from 77 to 80. That category is still filling its 30-day observation window: 23 days of observed history at the previous scan, 24 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-11-03 (score 82, +1)

No change was recorded against any check on this day. Stability & Change Management went from 70 to 73. That category is still filling its 30-day observation window: 21 days of observed history at the previous scan, 22 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-11-01 (score 81, +1)

No change was recorded against any check on this day. Stability & Change Management went from 63 to 67. That category is still filling its 30-day observation window: 19 days of observed history at the previous scan, 20 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-10-29 (score 80, +1)

No change was recorded against any check on this day. Stability & Change Management went from 53 to 57. That category is still filling its 30-day observation window: 16 days of observed history at the previous scan, 17 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-10-27 (score 79, +1)

No change was recorded against any check on this day. Stability & Change Management went from 47 to 50. That category is still filling its 30-day observation window: 14 days of observed history at the previous scan, 15 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-10-25 (score 78, +1)

No change was recorded against any check on this day. Stability & Change Management went from 40 to 43. That category is still filling its 30-day observation window: 12 days of observed history at the previous scan, 13 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-10-23 (score 77, +1)

No change was recorded against any check on this day. Stability & Change Management went from 33 to 37. That category is still filling its 30-day observation window: 10 days of observed history at the previous scan, 11 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-10-21 (score 76, +1)

No change was recorded against any check on this day. Stability & Change Management went from 27 to 30. That category is still filling its 30-day observation window: 8 days of observed history at the previous scan, 9 at this one. The score rises as the window fills, whether or not the server changes.

## MCP tools (6)

### `calculate_bess_system` (~322 tokens)

محاسبه ظرفیت باتری، توان اینورتر و تعداد پنل خورشیدی موردنیاز بر اساس لیست مصارف یا پیک بار. Calculate required battery capacity, inverter power and solar panel count for a backup or off-grid system.

Input parameters:

- `appliances` (array): لیست مصارف برقی
- `autonomyDays` (number): روزهای خودکفایی (حالت offgrid)
- `backupHours` (number): ساعات نیاز به بک‌آپ (حالت backup)
- `concurrencyPct` (number): ضریب همزمانی مصرف ٪ (حالت backup)
- `mode` (string): backup = برق اضطراری؛ offgrid = سیستم خورشیدی مستقل
- `panelEff` (number): راندمان سیستم ٪ (حالت offgrid؛ ۲۰٪ تلفات سیستم. حاشیه شارژ دوباره باتری و افت پنل جداگانه اعمال می‌شود)
- `panelW` (number): توان هر پنل خورشیدی (وات)؛ پنل‌های جینکو/ترینا ۶۲۵ تا ۷۴۰ وات
- `peakKW` (number): حداکثر توان مصرفی (kW). اگر appliances داده شود، خودکار محاسبه می‌شود
- `sunHours` (number): ساعات آفتابی موثر PSH در ماه کم‌تابش (حالت offgrid؛ تهران دی‌ماه ≈ 4)
- `template` (string): به‌جای appliances می‌توان یک الگوی آماده انتخاب کرد

### `suggest_products` (~325 tokens)

بر اساس نیاز محاسبه‌شده، محصولات مناسب انرویا پاور (اینورتر، باتری، پنل) را پیشنهاد می‌دهد. Suggest matching EnerviaPower products for the calculated system size. Accepts the same inputs as calculate_bess_system.

Input parameters:

- `appliances` (array): لیست مصارف برقی
- `autonomyDays` (number): روزهای خودکفایی (حالت offgrid)
- `backupHours` (number): ساعات نیاز به بک‌آپ (حالت backup)
- `concurrencyPct` (number): ضریب همزمانی مصرف ٪ (حالت backup)
- `mode` (string): backup = برق اضطراری؛ offgrid = سیستم خورشیدی مستقل
- `panelEff` (number): راندمان سیستم ٪ (حالت offgrid؛ ۲۰٪ تلفات سیستم. حاشیه شارژ دوباره باتری و افت پنل جداگانه اعمال می‌شود)
- `panelW` (number): توان هر پنل خورشیدی (وات)؛ پنل‌های جینکو/ترینا ۶۲۵ تا ۷۴۰ وات
- `peakKW` (number): حداکثر توان مصرفی (kW). اگر appliances داده شود، خودکار محاسبه می‌شود
- `sunHours` (number): ساعات آفتابی موثر PSH در ماه کم‌تابش (حالت offgrid؛ تهران دی‌ماه ≈ 4)
- `template` (string): به‌جای appliances می‌توان یک الگوی آماده انتخاب کرد

### `list_load_templates` (~47 tokens)

فهرست الگوهای آماده مصرف (آپارتمان، ویلا، دفتر، فروشگاه) به همراه دستگاه‌ها. List the built-in load profiles the calculator can start from.

### `list_products` (~54 tokens)

کاتالوگ محصولات انرویا پاور (ذخیره‌سازها، اینورترها، نیروگاه‌های قابل حمل). Return the EnerviaPower product catalog (storage, inverters, portable).

### `search_articles` (~125 tokens)

جست‌وجو در مقاله‌های آموزشی انرویا پاور (برق خورشیدی، باتری LiFePO4، برق اضطراری، اینورتر). Search the EnerviaPower knowledge base (Persian articles on solar, LiFePO4 batteries, backup power, inverters). Returns title, URL, excerpt and date; an empty query returns the newest articles.

Input parameters:

- `limit` (number): حداکثر تعداد نتیجه (۱ تا ۲۰)
- `query` (string): عبارت جست‌وجو (فارسی یا انگلیسی)

### `get_contact_info` (~60 tokens)

نشانی، تلفن، ساعات کاری و لینک ثبت درخواست خدمات (نصب، بازدید، تعمیر، گارانتی) انرویا پاور. EnerviaPower addresses, phone numbers, opening hours and the service-request / warranty URLs.

## Diagnostics

Captured diagnostic sections: TLS, DNSSEC, Authorisation, Transports. The full working is on the page: https://verifymcp.io/servers/com-enerviapower-bess/api-mcp#diagnostics

## Score history

- 2026-11-05: 83
- 2026-11-04: 82
- 2026-11-03: 82
- 2026-11-02: 81
- 2026-11-01: 81
- 2026-10-31: 80
- 2026-10-30: 80
- 2026-10-29: 80
- 2026-10-28: 79
- 2026-10-27: 79
- 2026-10-26: 78
- 2026-10-25: 78
- 2026-10-24: 77
- 2026-10-23: 77
- 2026-10-22: 76
- 2026-10-21: 76
- 2026-10-20: 75
- 2026-10-19: 75
- 2026-10-18: 74
- 2026-10-17: 74
- 2026-10-16: 73
- 2026-10-15: 73
- 2026-10-14: 73
- 2026-10-13: 72
- 2026-10-12: 72

## Common questions

### What is the Enervia Power — Solar & BESS sizing MCP server?

Enervia Power — Solar & BESS sizing is an MCP server listed in the public MCP registry as com.enerviapower/bess. Size solar, backup power and LiFePO4 battery systems for Iran; product picks and Persian guides. This page covers its hosted endpoint (https://www.enerviapower.com/api/mcp).

### Is the Enervia Power — Solar & BESS sizing MCP server safe to use?

Enervia Power — Solar & BESS sizing scores 83 out of 100 on VerifyMCP. That is a record of what we were able to check automatically, not an endorsement. The category breakdown on this page shows every signal behind the number, including the ones we could not confirm.

### What tools does the Enervia Power — Solar & BESS sizing MCP server expose?

Enervia Power — Solar & BESS sizing exposes 6 tools: calculate_bess_system, suggest_products, list_load_templates, list_products, search_articles, get_contact_info. Their descriptions and schemas cost roughly 933 tokens of context every time the server is loaded.

### Does the Enervia Power — Solar & BESS sizing MCP server require authentication?

No. We connected to Enervia Power — Solar & BESS sizing without credentials and it answered, so anything it exposes is reachable by anyone who knows the address.

### Is the Enervia Power — Solar & BESS sizing MCP server still maintained?

Enervia Power — Solar & BESS sizing is still listed as active in the MCP registry. We last reached this channel on 5 November 2026. Those dates come from our own scans of the registry and the channel itself, not from anything the publisher announced.

## Links

- Remote endpoint: https://www.enerviapower.com/api/mcp
- Website: https://www.enerviapower.com/
- Changelog RSS feed: https://verifymcp.io/servers/com-enerviapower-bess/api-mcp.xml
- Changelog JSON feed: https://verifymcp.io/servers/com-enerviapower-bess/api-mcp.json
- HTML version of this page: https://verifymcp.io/servers/com-enerviapower-bess/api-mcp
