io.github.octoco-ltd/sheetsdata-mcp
REMOTE · MCP.SHEETSDATA.COM · 2 COMPONENTS · SCANNED AUG 3
Electronic component datasheets for AI agents — specs, pinouts, package data on demand.
Available components
How this component scores in each security and reliability category. Every signal is checked automatically against the live server, and we only credit what we can confirm. How we score →
Endpoint Security89
- The endpoint's TLS certificate is valid, in date, and uses a strong key. View diagnostics → Pass
- Authorisation is enforced on tool calls, advertised via RFC 9728 protected-resource metadata. Discovery is public, which costs nothing: no tool can be invoked without a token. View diagnostics → Pass
- HTTPS is enforced; there's no plaintext access path. View diagnostics → Pass
- HSTS check failed: the Strict-Transport-Security header is absent. See how to fix → View diagnostics → Fail
- DNSSEC check failed: this domain isn't protected by DNSSEC. See how to fix → View diagnostics → Fail
- The authorisation server offers only Dynamic Client Registration (RFC 7591), which MCP 2026-07-28 deprecated in favour of Client ID Metadata Documents. View diagnostics → Partial
Transport & Reachability100
- Verified streamable-http transport via a live MCP handshake. View diagnostics → Pass
Schema Quality & AI Usability70
- 100% of prompts and resources have a non-trivial description (not blank, and not just the item's name).Pass
- AI-judged instruction clarity (good).Pass
- Context-footprint check failed: tool/resource definitions use about 7499 tokens (~499/item across 15 items; 12 tools + 3 resources), over budget; trim descriptions and params. See how to fix → Fail
- Usage-examples check failed: none of the tools include examples. See how to fix → Fail
Stability & Change Management27
- Stability observed for 8 of 30 days with no destabilising changes; credit accrues until the full window elapses.Partial
Tool Coverage100
- 100% of tools have a non-trivial description (not blank, and not just the tool's name).Pass
- 100% of tool parameters carry a description.Pass
Capabilities100
- Implements a supported MCP spec version (2025-11-25); the latest is 2026-07-28.Pass
Add this component to your MCP client. Where a client-specific snippet is available, pick your client below and copy it straight into your config; otherwise use the connection detail shown.
remote · mcp.sheetsdata.com
claude mcp add --transport http octoco-ltd-sheetsdata-mcp https://mcp.sheetsdata.com/mcp
[mcp_servers.octoco-ltd-sheetsdata-mcp] url = "https://mcp.sheetsdata.com/mcp"
{
"$schema": "https://opencode.ai/config.json",
"mcp": {
"octoco-ltd-sheetsdata-mcp": {
"type": "remote",
"url": "https://mcp.sheetsdata.com/mcp",
"enabled": true
}
}
} openclaw mcp add octoco-ltd-sheetsdata-mcp --url https://mcp.sheetsdata.com/mcp --transport streamable-http
mcp_servers:
octoco-ltd-sheetsdata-mcp:
url: "https://mcp.sheetsdata.com/mcp" {
"mcpServers": {
"octoco-ltd-sheetsdata-mcp": {
"type": "http",
"url": "https://mcp.sheetsdata.com/mcp"
}
}
} The mcpServers block is a cross-client convention. Remote transports vary, so check your client's docs.
Every change we have recorded for this component, newest first. Security-relevant changes are always shown. ▲ marks a change for the better, ▼ a change for the worse; unmarked changes are neutral.
- 3 Aug 26 +1
- Authorization: unverified → pass ▲ security
- Endpoint reachability: unreachable → reachable ▲ functional
- Schema quality: unverified → 100 ▲ functional
- Tool coverage: unverified → 100 ▲ functional
- Stability: unverified → 0.27 ▲ functional
- MCP protocol: unverified → pass ▲ functional
- 2 Aug 26 0
- Endpoint reachability: reachable → unreachable ▼ security
- Authorization: pass → unverified ▼ security
- Stability: 0.20 → unverified ▼ security
- Tool coverage: 100 → unverified ▼ functional
- Schema quality: 100 → unverified ▼ functional
- Capabilities: pass → unverified ▼ functional
- 1 Aug 26 +1
No change was recorded against any check on this day. Stability & Change Management went from 17 to 20. That category is still filling its 30-day observation window: 5 days of observed history at the previous scan, 6 at this one. The score rises as the window fills, whether or not the server changes.
- 31 Jul 26 +5
- We updated how we score, so this day's move reflects our rubric, not a change to the server See what changed → functional
- 30 Jul 26 0
- We updated how we score, so this day's move reflects our rubric, not a change to the server See what changed → functional
- 28 Jul 26 +1
No change was recorded against any check on this day. Stability & Change Management went from 3 to 7. That category is still filling its 30-day observation window: 1 days of observed history at the previous scan, 2 at this one. The score rises as the window fills, whether or not the server changes.
- 27 Jul 26 +1
- We updated how we score, so this day's move reflects our rubric, not a change to the server See what changed → functional
- 26 Jul 26 70
First indexed and scored.
Diagnostic detail from the automated scan of this channel: what the scanner observed at each step, so you can see exactly where a check passed or failed. It is informational only and never changes the trust score.
Captured 3 Aug 2026 · Probed https://mcp.sheetsdata.com/mcp
TLS valid
Negotiated TLS 1.3 with TLS_AES_128_GCM_SHA256 .
| Subject | Issuer | Valid from | Valid until | Key | Signature | Serial |
|---|---|---|---|---|---|---|
| CN=mcp.sheetsdata.com | CN=YR2,O=Let's Encrypt,C=US | 15 Jul 2026 | 13 Oct 2026 | RSA 2048 | SHA256-RSA | 5acdd543856559d67f3770076fe1df43aba |
| SANs: mcp.sheetsdata.com | ||||||
| CN=YR2,O=Let's Encrypt,C=US (CA) | CN=Root YR,O=ISRG,C=US | 3 Sept 2025 | 2 Sept 2028 | RSA 2048 | SHA256-RSA | 4ebd24947e24d394802d84a52fd5b319 |
| CN=Root YR,O=ISRG,C=US (CA) | CN=ISRG Root X1,O=Internet Security Research Group,C=US | 13 May 2026 | 2 Sept 2032 | RSA 4096 | SHA256-RSA | f24b6d17f9d9ad7cb1c9fea78782699f |
DNSSEC insecure
Validation of mcp.sheetsdata.com. — Not signed
| Zone | DS | Keys | Algorithms | Outcome |
|---|---|---|---|---|
| . | trust_anchor | 20326, 38696 | 8, 8 | Verified |
| com. | present | 19718 | 13 | Verified |
| sheetsdata.com. | absent | Unsigned (proven) parent-signed NSEC/NSEC3 proves an unsigned delegation |
Authentication Enforced and verified
The endpoint asked for a token and published valid RFC 9728 metadata describing how to get one.
| Result | Enforced and verified |
|---|---|
| Enforced | On tool calls |
| HTTP status | 200 |
WWW-Authenticate challenge Bearer error="invalid_token", error_description="Authentication required", resource_metadata="https://mcp.sheetsdata.com/.well-known/oauth-protected-resource/mcp"
Bearer error="invalid_token", error_description="Authentication required", resource_metadata="https://mcp.sheetsdata.com/.well-known/oauth-protected-resource/mcp" Protected resource metadata
| Document | https://mcp.sheetsdata.com/.well-known/oauth-protected-resource/mcp |
|---|---|
| Retrieved | Yes |
| Resource | https://mcp.sheetsdata.com/mcp |
| Authorisation server | https://mcp.sheetsdata.com/ |
Transports 2 probes
| Transport | URL | Outcome | Status | Location |
|---|---|---|---|---|
| streamable-http | https://mcp.sheetsdata.com/mcp | Verified | 200 | |
| http (plaintext) | http://mcp.sheetsdata.com/mcp | HTTPS enforced | 301 | https://mcp.sheetsdata.com/mcp |
The tools this component advertises to a client, with an estimated token cost for each. Expand a tool to see its parameters and schema. The per-tool counts are indicative and are not scored directly; the schema's total context footprint is one signal in Schema Quality & AI Usability.
analyze_image ~276
Analyze an image from a component's datasheet using vision AI. Use this when read_datasheet returns a section containing images and you need to extract data from a graph, package drawing, pin diagram, or circuit schematic. Pass the image_key from the read_datasheet response (the storage path in the image URL). Optionally pass a specific question to focus the analysis. IMPORTANT: For precise numeric values (electrical specs, max ratings), prefer read_datasheet text tables first — they are more reliable than vision-extracted graph data. Use analyze_image for visual information not available in text: package dimensions from drawings, pin assignments from diagrams, graph trends, and approximate values from characteristic curves. Examples: - analyze_image(part_number='IRFZ44N', image_key='images/abc123.png') -> classifies and describes the image - analyze_image(part_number='IRFZ44N', image_key='images/abc123.png', question='What is the drain current at Vgs=5V?')
| Name | Type | Req | Description |
|---|---|---|---|
| image_key | string | yes | Image storage path from read_datasheet output (e.g. 'images/abc123.png') |
| part_number | string | yes | MPN of the component |
| question | string | — | Optional specific question about the image (e.g. 'What are the package dimensions?') |
No output schema declared.
No examples provided.
check_design_fit ~930
Validate whether a component will work within your operating conditions. Compares your design parameters against the datasheet's absolute maximum ratings and recommended operating conditions. Returns PASS/FAIL/WARNING per parameter with margin percentages. Parameter mapping by component type: - Buck/boost converters: input_voltage, output_voltage, output_current, ambient_temp - MOSFETs: supply_voltage=VDS, output_current=ID (drain current), ambient_temp - LDOs: input_voltage, output_voltage, output_current, ambient_temp - Logic ICs: supply_voltage=VCC, ambient_temp Result semantics (per-parameter 'result' field): - PASS: comfortable margin. For a recommended-operating RANGE, any value inside the range (including the exact edges) is PASS. For an absolute-MAX rating, PASS means more than 10% below the limit. - WARNING: for absolute-max ratings only, the user value is within 10% of the limit (but not over) — part will work but with thin margin for part-to-part variation, temperature drift, and transients. Consider derating. - FAIL: user value is outside the allowed range / exceeds the limit — part is out of spec and will be stressed or damaged. - INSUFFICIENT_DATA: the check could not be completed safely — most commonly an ambient_temp input that could not be translated to a junction-temperature check (see the temperature note below). INSUFFICIENT_DATA never counts as a PASS: it pulls the overall verdict down to at-least-WARNING. Each check also reports 'limit_type' (max / min / range / fixed) so you can see whether it was judged against an operating range, an absolute-max rating, or a fixed-output setpoint. Temperature honesty: - ambient_temp is NOT silently treated as a junction temperature. The stored operating-temperature limit is junction-suspect, so a bare ambient input is never reported as a clean PASS on thermal grounds. If you also supply input_voltage, output_voltage and output_current AND a thermal-resistance (RthJA) value is available, the tool estimate…
| Name | Type | Req | Description |
|---|---|---|---|
| ambient_temp | number | — | Ambient temperature TA (°C). |
| input_voltage | number | — | Input voltage / VIN (V). For converters. |
| output_current | number | — | Output current / IOUT (A). For MOSFETs, this is drain current ID. |
| output_voltage | number | — | Output voltage / VOUT (V). For converters/LDOs. |
| part_number | string | yes | Specific manufacturer part number to validate. Not a value or description. |
| supply_voltage | number | — | Supply voltage / VCC / VDD (V). For MOSFETs, this is VDS (drain-source voltage). NOT used for power dissipation — compared against VDS(max) only. |
| switching_frequency | number | — | Switching frequency FSW (kHz). For converters. |
No output schema declared.
No examples provided.
check_extraction_status ~477
Check the extraction status of one or more parts. Free. Each entry includes the current extraction step, elapsed seconds, and document ID. Use after prefetch_datasheets or after read_datasheet triggers a new extraction. Recommended polling cadence: every 5-10 seconds. Extraction typically takes 30s-2min for new parts, so polling faster than every 5s wastes calls. Stop polling once status is 'ready', 'failed', 'no_source', or 'unsupported'. DATASHEET STATUS VALUES: - 'ready' — extracted and indexed; call read_datasheet, search_datasheets, or analyze_image. - 'extracting' / 'in_progress' / 'queued' / 'pending' — extraction running or scheduled. Poll check_extraction_status every 5-10s until 'ready' or 'failed'. Typical time: 30s-2min. - 'not_extracted' — known part but datasheet hasn't been fetched yet. Trigger it via prefetch_datasheets (cheapest) or by calling read_datasheet (auto-triggers on first read). - 'no_source' — we couldn't find a public datasheet URL for this MPN. First, retry prefetch_datasheets in 10-30s (the URL resolver re-runs and often finds a source on the second pass). If still 'no_source', the agent can upload the PDF manually via request_datasheet_upload + confirm_datasheet_upload (see those tools). Org-uploaded datasheets are private to the org. - 'unsupported' — PDF exists but can't be extracted (scanned image-only, encrypted, or corrupted). Upload a clean text-based PDF via request_datasheet_upload to override. - 'failed' / 'error' — extraction errored. The response includes the error reason. Retry via prefetch_datasheets or escalate to support. - 'rejected' — input wasn't a real MPN (bare value like '100nF', description, or reference designator). Fix the input and re-call. - 'deduplicated' — another part in the family already has this datasheet; same content is returned under the primary MPN.
| Name | Type | Req | Description |
|---|---|---|---|
| part_numbers | array | yes | 1-20 MPNs to check. Must be specific manufacturer part numbers, not values or descriptions. |
No output schema declared.
No examples provided.
compare_parts ~734
Compare 2-5 electronic components side by side in a single call. For each part, returns merged provider data (pricing, stock, structured parameters, package) plus the cached datasheet summary if one exists, plus datasheet_status ('ready', 'extracting', or 'not_extracted'). Use this instead of calling get_part_details in a loop — it fans out provider queries in parallel and merges by MPN. For *discovering* candidates, use search_parts or find_alternative first; compare_parts assumes you already know which MPNs you want to compare. Behavior: - Uses only cached datasheet summaries — does not trigger extraction. Call prefetch_datasheets first if you need summaries for parts that haven't been extracted yet. - Validates every MPN upfront. If *any* input is not a real part number (value, description, reference designator), the whole call is rejected with a 'rejected' map listing the offenders — other parts are not compared. Filter your list before calling. - If a valid MPN is not found at any provider, that part still appears in the response with an 'error' field; the other parts are compared normally. IMPORTANT — part_numbers must be specific manufacturer part numbers (e.g. 'TPS54302DDCR', 'STM32F446RCT6') or LCSC numbers (e.g. 'C2837938'). Do NOT pass component values ('100nF', '10K'), descriptions ('buck converter'), or reference designators ('U3', 'R1'). Example: compare_parts(['TPS54302', 'LM2596', 'MP2359']) DATASHEET STATUS VALUES: - 'ready' — extracted and indexed; call read_datasheet, search_datasheets, or analyze_image. - 'extracting' / 'in_progress' / 'queued' / 'pending' — extraction running or scheduled. Poll check_extraction_status every 5-10s until 'ready' or 'failed'. Typical time: 30s-2min. - 'not_extracted' — known part but datasheet hasn't been fetched yet. Trigger it via prefetch_datasheets (cheapest) or by calling read_datasheet (auto-triggers on first read). - 'no_source' — we couldn't find a public datasheet URL for this MPN. First, retry prefe…
| Name | Type | Req | Description |
|---|---|---|---|
| part_numbers | array | yes | 2-5 specific manufacturer part numbers or LCSC numbers to compare head-to-head. Must be real MPNs — the call is rejected upfront if any entry is a value, description, or reference designator. |
No output schema declared.
No examples provided.
confirm_datasheet_upload ~270
Confirm a datasheet upload started via request_datasheet_upload. Pass the upload_token you got back from the request step. The server downloads the uploaded bytes, re-hashes to verify integrity, validates that it's a real PDF with the MPN on the first page, creates the private Document + Component records, charges the upload fee (50¢), and queues extraction. Success response: document_id, mpn, sha256, file_size_bytes, status='pending'. Poll check_extraction_status with the MPN to wait for extraction to finish (30s-2min typically). Failure modes: - 'upload_not_found' — no bytes at the upload URL yet. Retry your curl upload. - 'sha256_mismatch' — uploaded bytes hash differs from expected_sha256. Re-compute the hash and re-request. - 'invalid_pdf' — bytes aren't a parseable PDF. No charge. - 'mpn_not_in_pdf' — MPN (or its stem) isn't on the first page. Either you uploaded the wrong file or it's a scanned image-only PDF. No charge. - 'token_expired' — upload token is older than 15 minutes. Restart via request_datasheet_upload.
| Name | Type | Req | Description |
|---|---|---|---|
| upload_token | string | yes | Opaque token returned by request_datasheet_upload. |
No output schema declared.
No examples provided.
find_alternative ~730
Find alternative / second-source components for a given MPN. Returns parts ranked by how closely their specs, package, and category match the reference part, with a match_score and match_notes explaining each match. When to use: - Original part is out of stock or end-of-life. - You need a cheaper equivalent with similar specs. - You need a second source for supply-chain resilience. - You need a drop-in replacement on an existing PCB (use constraints=['same_package']). When NOT to use: - You're browsing a category from scratch — use search_parts. - You already have candidates and want a head-to-head comparison — use compare_parts directly. Behavior: - Eval boards, dev kits, and breakout modules are filtered out — results are IC-level alternatives only. - 'same_package' uses fuzzy matching, so SOT-23 ≡ SOT23, SOIC-8 ≡ SOP-8, LQFP64 ≡ TQFP64, etc. Exact string match is not required. - If provider search returns few candidates, the tool falls back to semantic search across extracted datasheets to surface niche alternatives. - The response includes a 'hint' field pointing to compare_parts / read_datasheet for drilling into promising alternatives. Example: find_alternative('TPS54302', constraints=['same_package', 'in_stock']) DATASHEET STATUS VALUES: - 'ready' — extracted and indexed; call read_datasheet, search_datasheets, or analyze_image. - 'extracting' / 'in_progress' / 'queued' / 'pending' — extraction running or scheduled. Poll check_extraction_status every 5-10s until 'ready' or 'failed'. Typical time: 30s-2min. - 'not_extracted' — known part but datasheet hasn't been fetched yet. Trigger it via prefetch_datasheets (cheapest) or by calling read_datasheet (auto-triggers on first read). - 'no_source' — we couldn't find a public datasheet URL for this MPN. First, retry prefetch_datasheets in 10-30s (the URL resolver re-runs and often finds a source on the second pass). If still 'no_source', the agent can upload the PDF manually via request_datasheet_upload + con…
| Name | Type | Req | Description |
|---|---|---|---|
| constraints | array | — | Optional filters to narrow alternatives. 'in_stock' = only parts with non-zero stock at any provider. 'same_package' = package footprint must match (fuzzy). 'jlcpcb' = must be available at JLCPCB (us… |
| limit | integer | — | Max alternatives to return (default 5, max 20). |
| part_number | string | yes | The MPN to find alternatives for |
No output schema declared.
No examples provided.
get_part_details ~593
Get full details for a specific electronic component by manufacturer part number (MPN) or LCSC number. Returns specs, pricing, and stock from all configured providers, plus the cached datasheet summary if available. Includes datasheet_status and available_sections when ready. Set prefetch_datasheet=true to trigger background extraction — no extra charge. Use after search_parts to drill into a specific result. The part_number must be a specific manufacturer part number (e.g. 'TPS54302DDCR', 'STM32F446RCT6') or LCSC number (e.g. 'C2837938'). Do NOT pass bare component values ('100nF', '10K'), descriptions ('buck converter'), or reference designators ('R1', 'U3'). DATASHEET STATUS VALUES: - 'ready' — extracted and indexed; call read_datasheet, search_datasheets, or analyze_image. - 'extracting' / 'in_progress' / 'queued' / 'pending' — extraction running or scheduled. Poll check_extraction_status every 5-10s until 'ready' or 'failed'. Typical time: 30s-2min. - 'not_extracted' — known part but datasheet hasn't been fetched yet. Trigger it via prefetch_datasheets (cheapest) or by calling read_datasheet (auto-triggers on first read). - 'no_source' — we couldn't find a public datasheet URL for this MPN. First, retry prefetch_datasheets in 10-30s (the URL resolver re-runs and often finds a source on the second pass). If still 'no_source', the agent can upload the PDF manually via request_datasheet_upload + confirm_datasheet_upload (see those tools). Org-uploaded datasheets are private to the org. - 'unsupported' — PDF exists but can't be extracted (scanned image-only, encrypted, or corrupted). Upload a clean text-based PDF via request_datasheet_upload to override. - 'failed' / 'error' — extraction errored. The response includes the error reason. Retry via prefetch_datasheets or escalate to support. - 'rejected' — input wasn't a real MPN (bare value like '100nF', description, or reference designator). Fix the input and re-call. - 'deduplicated' — another part in the family…
| Name | Type | Req | Description |
|---|---|---|---|
| part_number | string | yes | Specific manufacturer part number (MPN) or LCSC number (e.g. 'C2837938'). Not a value or description. |
| prefetch_datasheet | boolean | — | Trigger background datasheet extraction (no extra charge). Default false. |
| provider | string | — | Which provider to query: 'all' (default), 'jlcpcb', 'mouser', or 'digikey' |
No output schema declared.
No examples provided.
prefetch_datasheets ~619
Trigger background datasheet extraction for multiple parts at once (up to 20). Non-blocking — returns immediately with the status of each part. Use this to warm up datasheets for a BOM before calling read_datasheet. Example: prefetch_datasheets(['TPS54302', 'ADS1115', 'LP5907']) If a part comes back 'no_source' on the first call, retry prefetch for that MPN once after 10-30s — the URL resolver is retriable and often finds a source on the second pass. If still 'no_source', use request_datasheet_upload + confirm_datasheet_upload to attach your own PDF (org-private). Part numbers must be specific MPNs (e.g. 'STM32F446RCT6', 'TPS54302DDCR') or LCSC numbers (e.g. 'C2837938'). Do NOT pass bare values ('100nF', '10K'), descriptions, BOM reference designators, test points, or board/module names — see the server instructions for the full rule set. When a BOM has values-only rows, use search_parts first to resolve each to an MPN. DATASHEET STATUS VALUES: - 'ready' — extracted and indexed; call read_datasheet, search_datasheets, or analyze_image. - 'extracting' / 'in_progress' / 'queued' / 'pending' — extraction running or scheduled. Poll check_extraction_status every 5-10s until 'ready' or 'failed'. Typical time: 30s-2min. - 'not_extracted' — known part but datasheet hasn't been fetched yet. Trigger it via prefetch_datasheets (cheapest) or by calling read_datasheet (auto-triggers on first read). - 'no_source' — we couldn't find a public datasheet URL for this MPN. First, retry prefetch_datasheets in 10-30s (the URL resolver re-runs and often finds a source on the second pass). If still 'no_source', the agent can upload the PDF manually via request_datasheet_upload + confirm_datasheet_upload (see those tools). Org-uploaded datasheets are private to the org. - 'unsupported' — PDF exists but can't be extracted (scanned image-only, encrypted, or corrupted). Upload a clean text-based PDF via request_datasheet_upload to override. - 'failed' / 'error' — extraction errored. The r…
| Name | Type | Req | Description |
|---|---|---|---|
| part_numbers | array | yes | List of MPNs to prefetch (max 20). Must be specific manufacturer part numbers, not values or descriptions. |
No output schema declared.
No examples provided.
read_datasheet ~821
Read from a component's datasheet. Two modes: **Section mode** (default): Returns a named section. Start with section='summary' to get an overview and a list of available_sections. Then request specific sections by name. Section names are dynamic — any heading in the actual datasheet works (e.g. 'register_map', 'i2c_interface', 'power_management'). If a section name isn't found, automatically falls back to search mode. **Search mode**: Semantic search within the part's datasheet. Best for targeted questions (register bit fields, I2C config, specific specs). Use when you need to find specific information rather than a whole section. First call for a new part triggers extraction (30s-2min). Subsequent calls are cached. **Datasheet vs Reference Manual**: Manufacturer datasheets cover high-level specs, pinout, absolute maximum ratings, and package info. For microcontrollers (STM32, nRF52, RP2040), register-level programming details (I2C CR1/CR2, DMA config, interrupt bits) are in a separate Reference Manual, not the datasheet. The summary's available_sections will show what's actually present. The part_number must be a specific manufacturer part number (e.g. 'TPS54302', 'STM32F446RCT6') or LCSC number (e.g. 'C2837938'). Do NOT pass bare component values ('100nF', '10K'), descriptions, or reference designators. DATASHEET STATUS VALUES: - 'ready' — extracted and indexed; call read_datasheet, search_datasheets, or analyze_image. - 'extracting' / 'in_progress' / 'queued' / 'pending' — extraction running or scheduled. Poll check_extraction_status every 5-10s until 'ready' or 'failed'. Typical time: 30s-2min. - 'not_extracted' — known part but datasheet hasn't been fetched yet. Trigger it via prefetch_datasheets (cheapest) or by calling read_datasheet (auto-triggers on first read). - 'no_source' — we couldn't find a public datasheet URL for this MPN. First, retry prefetch_datasheets in 10-30s (the URL resolver re-runs and often finds a source on the second pass). If st…
| Name | Type | Req | Description |
|---|---|---|---|
| limit | integer | — | Max search results for search mode (default 10). Each result includes adjacent context chunks for continuity. |
| mode | string | — | Reading mode: 'section' (default) returns a named section, 'search' does semantic search |
| part_number | string | yes | Specific manufacturer part number (MPN) or LCSC number. Not a value or description. |
| query | string | — | Search query — REQUIRED when mode='search', ignored when mode='section'. Example: 'charge voltage register', 'I2C address'. |
| section | string | — | Section name for section mode. Start with 'summary' to discover available sections. Common: summary, pinout, electrical, abs_max, register_map, timing, package. Any heading in the datasheet works (sl… |
No output schema declared.
No examples provided.
request_datasheet_upload ~548
Request a signed URL to upload a datasheet PDF for a component whose datasheet we don't have. Use this when search_parts / get_part_details / prefetch_datasheets return datasheet_status='no_source' (and a retry didn't help) or 'unsupported'. Free — the upload fee is only charged on confirm_datasheet_upload after we validate the file. Flow (3 steps): 1. Call request_datasheet_upload with the MPN, the file's SHA-256, and its byte size. You get back an upload_url, upload_method ('PUT'), upload_headers, and an opaque upload_token. 2. Upload the PDF directly to the returned URL with curl: `curl -X PUT -H 'Content-Type: application/pdf' --data-binary @file.pdf "$UPLOAD_URL"` (add any headers from upload_headers). 3. Call confirm_datasheet_upload with the upload_token. Server verifies the bytes, re-hashes, checks for the MPN on the first page, charges the upload fee (50¢), and queues extraction. Returns document_id + status='pending'. Validation rules (checked at confirm time, refunded on failure): - File must be a valid PDF (magic bytes + parseable). - Actual SHA-256 must match expected_sha256. - Actual byte size must match size_bytes (±0). - MPN or its core stem must appear in the first page text (catches wrong-file uploads). Scanned image-only PDFs will fail this check — upload a text-based PDF. - Max 50MB per file. No dev-kit manuals / BOB schematics / app-notes as datasheets — use the matching MPN's actual datasheet. Uploaded datasheets are scoped to your organization (private). They satisfy read_datasheet, search_datasheets, check_design_fit, and analyze_image for your org's tokens only. Tokens expire after 15 minutes. If upload fails or times out, just call request_datasheet_upload again.
| Name | Type | Req | Description |
|---|---|---|---|
| expected_sha256 | string | yes | Lowercase hex SHA-256 of the PDF bytes (64 chars). Used both as the storage key (content-addressed) and to detect tampering. Compute with `shasum -a 256 file.pdf`. |
| manufacturer | string | — | Optional. Manufacturer name (e.g. 'Texas Instruments') if the MPN alone doesn't disambiguate. |
| part_number | string | yes | Manufacturer part number the PDF belongs to. Must be a real MPN, not a value or description. |
| size_bytes | integer | yes | Size of the PDF in bytes. Must be ≤ 50_000_000 (50MB) and > 1024. |
No output schema declared.
No examples provided.
search_datasheets ~128
Semantic search across all extracted datasheets. Finds components matching natural language queries about specifications, features, or capabilities. Best for broad spec-based discovery across all parts (e.g. 'low-noise LDO with PSRR above 70dB'). Only searches datasheets that have been previously extracted — not all parts that exist. For finding specific parts by number, use search_parts instead.
| Name | Type | Req | Description |
|---|---|---|---|
| limit | integer | — | Max results (default 15) |
| query | string | yes | Natural language search query |
| section_type | string | — | Optional: limit search to a specific section type |
No output schema declared.
No examples provided.
search_parts ~593
Search for electronic components by part number, description, or keyword. Start here — this is the best entry point for finding components. Queries all configured providers in parallel. Results are merged by MPN with indicative pricing and stock from each source. Each result includes datasheet_status so you know which parts have datasheets available for read_datasheet. Best with specific part numbers or keywords (e.g. 'STM32F103', 'buck converter 3A'). For spec-based discovery in natural language, use search_datasheets instead. When the calling org has a private parts library, matching org-uploaded parts are appended to the results with source='private_library' and any tags the team has applied — including private parts whose MPN, manufacturer, description, type, category, or tag matches the query. DATASHEET STATUS VALUES: - 'ready' — extracted and indexed; call read_datasheet, search_datasheets, or analyze_image. - 'extracting' / 'in_progress' / 'queued' / 'pending' — extraction running or scheduled. Poll check_extraction_status every 5-10s until 'ready' or 'failed'. Typical time: 30s-2min. - 'not_extracted' — known part but datasheet hasn't been fetched yet. Trigger it via prefetch_datasheets (cheapest) or by calling read_datasheet (auto-triggers on first read). - 'no_source' — we couldn't find a public datasheet URL for this MPN. First, retry prefetch_datasheets in 10-30s (the URL resolver re-runs and often finds a source on the second pass). If still 'no_source', the agent can upload the PDF manually via request_datasheet_upload + confirm_datasheet_upload (see those tools). Org-uploaded datasheets are private to the org. - 'unsupported' — PDF exists but can't be extracted (scanned image-only, encrypted, or corrupted). Upload a clean text-based PDF via request_datasheet_upload to override. - 'failed' / 'error' — extraction errored. The response includes the error reason. Retry via prefetch_datasheets or escalate to support. - 'rejected' — input wasn't a real MP…
| Name | Type | Req | Description |
|---|---|---|---|
| limit | integer | — | Max results per provider (default 20). With providers='all', total results can be up to 3× this value (one set per provider). |
| providers | string | — | Which providers to query: 'all' (default), 'jlcpcb', 'mouser', or 'digikey' |
| query | string | yes | Search query (part number or keyword) |
No output schema declared.
No examples provided.