com.civilquants/civilquants
REMOTE · API.CIVILQUANTS.COM · SCANNED AUG 3
Parametric estimating engine: CESMM4/NRM2/SMM7/MMHW Bills of Quantities for civils assemblies.
Available components
How this component scores in each security and reliability category. Every signal is checked automatically against the live server, and we only credit what we can confirm. How we score →
Endpoint Security57
- The endpoint's TLS certificate is valid, in date, and uses a strong key. View diagnostics → Pass
- Authorisation not fully verified: no authorisation is required to call this server, and 55 tool(s) never declared a destructiveHint. The MCP spec treats an absent hint as destructive by default, so we cannot call this surface safe. See how to fix → View diagnostics → Unverified
- HTTPS is enforced; there's no plaintext access path. View diagnostics → Pass
- HSTS check failed: the Strict-Transport-Security header is absent. See how to fix → View diagnostics → Fail
- DNSSEC check failed: this domain isn't protected by DNSSEC. See how to fix → View diagnostics → Fail
Transport & Reachability100
- Verified streamable-http transport via a live MCP handshake. View diagnostics → Pass
Schema Quality & AI Usability50
- 100% of prompts and resources have a non-trivial description (not blank, and not just the item's name).Pass
- AI-judged instruction clarity (poor).Fail
- Context-footprint check failed: tool/resource definitions use about 26746 tokens (~417/item across 64 items; 56 tools + 8 resources), over budget; trim descriptions and params. See how to fix → Fail
- Usage-examples check failed: none of the tools include examples. See how to fix → Fail
Stability & Change Management27
- Stability observed for 8 of 30 days with no destabilising changes; credit accrues until the full window elapses.Partial
Tool Coverage77
- 100% of tools have a non-trivial description (not blank, and not just the tool's name).Pass
- 19% of tool parameters carry a description.Partial
- Structured output schemas are declared (100% of tools); any adoption earns full credit.Pass
Capabilities100
- Implements a supported MCP spec version (2025-11-25); the latest is 2026-07-28.Pass
Add this component to your MCP client. Where a client-specific snippet is available, pick your client below and copy it straight into your config; otherwise use the connection detail shown.
remote · api.civilquants.com
claude mcp add --transport http com-civilquants-civilquants https://api.civilquants.com/mcp
[mcp_servers.com-civilquants-civilquants] url = "https://api.civilquants.com/mcp"
{
"$schema": "https://opencode.ai/config.json",
"mcp": {
"com-civilquants-civilquants": {
"type": "remote",
"url": "https://api.civilquants.com/mcp",
"enabled": true
}
}
} openclaw mcp add com-civilquants-civilquants --url https://api.civilquants.com/mcp --transport streamable-http
mcp_servers:
com-civilquants-civilquants:
url: "https://api.civilquants.com/mcp" {
"mcpServers": {
"com-civilquants-civilquants": {
"type": "http",
"url": "https://api.civilquants.com/mcp"
}
}
} The mcpServers block is a cross-client convention. Remote transports vary, so check your client's docs.
Every change we have recorded for this component, newest first. Security-relevant changes are always shown. ▲ marks a change for the better, ▼ a change for the worse; unmarked changes are neutral.
- 3 Aug 26 +1
No change was recorded against any check on this day. Stability & Change Management went from 23 to 27. That category is still filling its 30-day observation window: 7 days of observed history at the previous scan, 8 at this one. The score rises as the window fills, whether or not the server changes.
- 1 Aug 26 +1
No change was recorded against any check on this day. Stability & Change Management went from 17 to 20. That category is still filling its 30-day observation window: 5 days of observed history at the previous scan, 6 at this one. The score rises as the window fills, whether or not the server changes.
- 31 Jul 26 +2
- We updated how we score, so this day's move reflects our rubric, not a change to the server See what changed → functional
- 30 Jul 26 +1
- We updated how we score, so this day's move reflects our rubric, not a change to the server See what changed → functional
- 28 Jul 26 +1
No change was recorded against any check on this day. Stability & Change Management went from 3 to 7. That category is still filling its 30-day observation window: 1 days of observed history at the previous scan, 2 at this one. The score rises as the window fills, whether or not the server changes.
- 27 Jul 26 +1
- We updated how we score, so this day's move reflects our rubric, not a change to the server See what changed → functional
- 26 Jul 26 53
First indexed and scored.
Diagnostic detail from the automated scan of this channel: what the scanner observed at each step, so you can see exactly where a check passed or failed. It is informational only and never changes the trust score.
Captured 3 Aug 2026 · Probed https://api.civilquants.com/mcp
TLS valid
Negotiated TLS 1.3 with TLS_AES_128_GCM_SHA256 .
| Subject | Issuer | Valid from | Valid until | Key | Signature | Serial |
|---|---|---|---|---|---|---|
| CN=civilquants.com | CN=YE1,O=Let's Encrypt,C=US | 16 Jun 2026 | 14 Sept 2026 | ECDSA 256 | ECDSA-SHA384 | 61df89dec87f25936a13a098e86a27b34b0 |
| SANs: *.civilquants.com, civilquants.com | ||||||
| CN=YE1,O=Let's Encrypt,C=US (CA) | CN=Root YE,O=ISRG,C=US | 3 Sept 2025 | 2 Sept 2028 | ECDSA 384 | ECDSA-SHA384 | 5ddd70dd31f801c85c186a7a04b80afe |
| CN=Root YE,O=ISRG,C=US (CA) | CN=ISRG Root X2,O=Internet Security Research Group,C=US | 13 May 2026 | 2 Sept 2032 | ECDSA 384 | ECDSA-SHA384 | 872165fc34b6e5fba8add5b3705fb53a |
| CN=ISRG Root X2,O=Internet Security Research Group,C=US (CA) | CN=ISRG Root X1,O=Internet Security Research Group,C=US | 13 May 2026 | 2 Sept 2032 | ECDSA 384 | SHA256-RSA | 6c8f1dc727c7117f7baf853ac980f9cd |
DNSSEC insecure
Validation of api.civilquants.com. — Not signed
| Zone | DS | Keys | Algorithms | Outcome |
|---|---|---|---|---|
| . | trust_anchor | 20326, 38696 | 8, 8 | Verified |
| com. | present | 19718 | 13 | Verified |
| civilquants.com. | absent | Unsigned (proven) parent-signed NSEC/NSEC3 proves an unsigned delegation |
Authentication No authorisation required
The endpoint answered without asking for a token. Anyone who knows the URL can reach it.
| Result | No authorisation required |
|---|---|
| HTTP status | 200 |
Transports 2 probes
| Transport | URL | Outcome | Status | Location |
|---|---|---|---|---|
| streamable-http | https://api.civilquants.com/mcp | Verified | 200 | |
| http (plaintext) | http://api.civilquants.com/mcp | HTTPS enforced | 301 | https://api.civilquants.com/mcp |
The tools this component advertises to a client, with an estimated token cost for each. Expand a tool to see its parameters and schema. The per-tool counts are indicative and are not scored directly; the schema's total context footprint is one signal in Schema Quality & AI Usability.
compute_anchored_wall Compute Anchored Retaining Wall BoQ ~688
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_cantilever_wall. Anchored retaining wall — the only wall family member that pre-stresses the retained soil mass into the wall via post-tensioned ground anchors per BS EN 1537. Three structural variants: in-situ reinforced concrete (INSITU_RC, economic 5-10m); steel king-post-and-lagging (KING_POST, typical 4-8m, often temporary); driven sheet pile (SHEET_PILED, quays/cofferdams/deep basements). Eight VARIANT_PRESETS exercise the 'one parameter form, eight variants, four standards' moat #1 claim across all three structural variants. The in-situ RC body routes via wall_type='anchored' attribute discrimination: CESMM4 F.6.4, NRM2 11.3.4, MMHW 1700.4.3 (SHW Cl. 1709/1710), SMM7 E10.3.3. Ground anchors and stressing route to new specialist handlers (CESMM4 Class C; NRM2 Group 7; MMHW Series 1600; SMM7 D32). King-post sections to CESMM4 P.5 / NRM2 7.3 / MMHW 1600.3 / SMM7 D32; sheet piles to CESMM4 P.4 / NRM2 7.4 / MMHW 1600.4 / SMM7 D31; timber lagging to CESMM4 O.3 / NRM2 16.4 / MMHW 2500.7 / SMM7 G20.1. Example params: stem_height=6 m (2–15), stem_thickness=0.5 m (0–1.5), wall_length=25 m (5–200). Example call: {"params": {"stem_height": 6, "stem_thickness": 0.5, "wall_length": 25}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier). Pass `freeboard` (clearance below the wall top, m) instead of the retained-height field to set the retained fill by clearance — the engine back-calculates it as stem − freeboard. Supplying both is rejected.
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| freeboard | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameter form for an anchored retaining wall. A single dataclass that — through combinations of its fields and the ``wall_form`` discriminator — produces all eight VARIANT_PRESETS plus arbitrary us… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_attenuation_tank Compute Stormwater Attenuation Tank BoQ ~265
Free tier. Renders the MMHW standard only — CESMM4, NRM2 and SMM7 require a paid tier. Anonymous callers welcome. Stormwater attenuation tank supporting two configurations: modular geocellular crates (high void ratio, compact footprint) or large-bore pipe arrays (1.5m+ ID concrete pipes in parallel runs). Excavation may be open-battered or vertical-sided with sheet pile support. Example params: tank_length=30 m (2–200), crate_width=6 m (1–20), crate_height=1.2 m (0.4–3.6). Example call: {"params": {"tank_length": 30, "crate_width": 6, "crate_height": 1.2}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | — |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_bored_pile_wall Compute Bored Pile Retaining Wall BoQ ~783
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_cantilever_wall. Cast-in-place bored concrete pile retaining wall, the SEVENTH member of the wall family and the FIFTH of the retaining_walls L1 leaf. The SIXTH structural system in the retaining / earth-structures domain (after mass concrete / RC / steel / mesh-and-stone / reinforced-soil-with-facing). Four structural forms via the bored_pile_form discriminator: CONTIGUOUS (clear-spaced piles, shotcrete face), SECANT_HARD_SOFT (alternating soft/hard overlapping piles, intermediate watertightness), SECANT_HARD_HARD (overlapping RC piles, maximum watertightness; deep basements), and KING_POST_AND_LAGGING_RC (widely-spaced RC king posts with lagging panels). 18th use of the classed-then-legacy attribute discrimination pattern, applied via the CONCRETE_REINFORCED handler's new wall_type='bored_pile' branch for the capping beam (when included). Routes via five new WorkCategory entries (BORED_PILE_CONCRETE, BORED_PILE_BORE, BORED_PILE_NR, BORED_PILE_HEAD_PREP, BORED_PILE_INTERLOCK) covering the CESMM4 Class P §P.8 three-line cast-in-place pile measurement convention plus the Class Q ancillaries head-prep line and the secant-specific interlock line. Codes: CESMM4 P.8.1-4 + Q.1.1, NRM2 7.6.1-4 + 7.5.1, MMHW 1600.5-6 (SHW Cl. 1602/1603), and SMM7 D30.1-5 — D30 (Cast in place piling) is OPENED at this session as the conventional UK QS named home. Capping beam routes via CONCRETE_REINFORCED with wall_type='bored_pile' to F.6.5 / 11.3.5 / 1700.4.4 / E10.3.4. Reinforcement billed itemised (separate audit line per BS 8666:2020 cage) on top of the pile rate by S31 decision. Eight variant presets exercise all four BoredPileForm values (2/2/2/2 split). Example params: wall_length_m=20 m (5–200), retained_height_m=6 m (2–20), embedment_below_formation_m=4 m (1–15). Example call: {"params": {"wall_le…
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameter form for a bored pile retaining wall. A single dataclass that — through combinations of its fields and the ``bored_pile_form`` discriminator — produces all eight VARIANT_PRESETS plus arbit… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_box_culvert Compute Precast Concrete Box Culvert BoQ ~617
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Precast concrete box culvert run (Marshalls / FP McCann / CPM ranges, BS EN 14844 / BS 5911-3) of one of eight catalogue sizes from BC_600 (600 × 600mm) to BC_3000x2000 (3000 × 2000mm). Composes the precast units (N per run), concrete blinding bedding, geotextile separator, selected granular surround per SHW Cl. 503, and foundation excavation with optional sheet pile support. Optional headwall_attenuation_outlet (2nd use of S21) at each termination with independently parameter-selectable scour protection (rock armour, gabion mattress, concrete apron, or none). Routes BOX_CULVERT_UNIT via CESMM4 H.7.3/.4/.5 (precast concrete, size banded), NRM2 33.8.1/.2/.3, MMHW 500.12.1/.2/.3 (with Series 2500 signpost for large units per Volume 4 NG 25), and SMM7 R12.4.5/.6/.7. Example params: total_length_m=12 m (1–200), invert_depth_m=2.5 m (0.5–15), invert_gradient=0.005 (0–0.08). Example call: {"params": {"total_length_m": 12, "invert_depth_m": 2.5, "invert_gradient": 0.005}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameter form for a precast concrete box culvert run. Catalogue-driven: pick a ``size`` and the section's nominal span / height / mass / wall thickness are read from ``_CATALOGUE``. Override indivi… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_cantilever_wall Compute Cantilever Retaining Wall BoQ ~309
Free tier. Renders the MMHW standard only — CESMM4, NRM2 and SMM7 require a paid tier. Anonymous callers welcome. In-situ reinforced concrete cantilever retaining wall with toe, heel, and stem. Includes excavation, blinding, drainage, and backfill quantities. Example params: stem_height=4 m (2–8), stem_thickness_top=0.3 m (0.2–0.6), stem_thickness_bottom=0.45 m (0.25–0.9). Example call: {"params": {"stem_height": 4, "stem_thickness_top": 0.3, "stem_thickness_bottom": 0.45}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier). Pass `freeboard` (clearance below the wall top, m) instead of the retained-height field to set the retained fill by clearance — the engine back-calculates it as stem − freeboard. Supplying both is rejected.
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| freeboard | — | — | — |
| output_mode | string | — | — |
| params | object | yes | — |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_carrier_pipe_run Compute Carrier Pipe Run (banded) BoQ ~560
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Linear carrier-pipe measurement assembly with full four-standard depth-banded rendering. CESMM4 Class I (I.{material}.{bore}.{depth}, 9 depth bands), NRM2 Group 33 (33.1.{bore}.{depth}, equivalent banding), MMHW Series 500 (500.1.{bore}.{depth}, 11 depth bands extending to 6 m for highway-scale carriers per SHW Cl. 501), SMM7 R12 (R12.1.{bore}.{depth}, 10 depth bands starting at 1 m for housing-scale carriers). Twelve variant presets exercise all 9 CESMM4 Class I depth bands and all 5 carrier materials (vitrified clay / concrete / HDPE / ductile iron / uPVC) — 12 × 4 = 48 distinguishable BoQ rows from a single parameter form. 19th use of the classed-then-legacy attribute discrimination pattern, FIRST applied to a Class I (Pipework) category — discriminator here is `material` itself, with the CESMM4 handler routing through the 5 Class I material sub-class digits while NRM2/MMHW/SMM7 stay within their respective groups but distinguish material in the description. Companion assembly: connection_to_existing (S32 sibling pair) — the enumerated extra-over connection line that ties a carrier run into an adopted asset. Example params: diameter_mm=225 mm (100–2400), invert_depth_m=1.8 m (0.5–10), run_length_m=30 m (1–2000). Example call: {"params": {"diameter_mm": 225, "invert_depth_m": 1.8, "run_length_m": 30}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameters for a carrier pipe run. Geometric defaults yield a DN225 vitrified clay carrier at 1.8 m average invert depth over a 30 m run — the textbook small-civils foul carrier described in the QS… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_catchpit Compute Precast Concrete Catchpit / Silt Trap BoQ ~533
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Precast concrete catchpit / silt trap to BS 5911-3 comprising factory-cast monolithic base with integral silt sump (600-900mm below outlet invert), stacked precast chamber rings, precast cover slab, ductile-iron frame and cover (BS EN 124 loading classes), optional step irons, granular or concrete bedding, granular surround, geotextile separator, and excavation. Catalogue-driven sizing from CP_900 (900mm ID) to CP_1800 (1800mm ID). Routes via chamber_type='catchpit' attribute discrimination through CESMM4 K.1.6.x, NRM2 33.7.14, MMHW 500.5.16 (SHW Cl. 511 silt traps), and SMM7 R12.3.13. Distinct from manholes by the silt-sump-below-channel geometry; typical position upstream of petrol/oil interceptor (S24) in a forecourt or service-area drainage train. Example params: invert_depth=2.5 m (0.5–10), bedding_thickness_mm=150 mm (100–300), bedding_overhang_m=0.15 m (0.1–0.3). Example call: {"params": {"invert_depth": 2.5, "bedding_thickness_mm": 150, "bedding_overhang_m": 0.15}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameter form for a precast concrete catchpit / silt trap. Catalogue-driven: pick a ``size`` and the chamber's nominal dimensions, masses, and silt-sump depth are read from ``_CATALOGUE``. Override… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_combined_services_trench Compute Combined Services Trench BoQ ~343
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Shared utility trench carrying multiple services side by side, each at its own cover depth (water, gas, electricity, telecoms) per NJUG Volume 1. One excavation envelope sized from the services, one disposal, one backfill column, with per-service lane-width bedding, surround, pipe/duct, and warning tape. Renders through CESMM4 Class I, NRM2 Group 41, MMHW Series 1300 and SMM7 Group T for the services, with the shared envelope routing through the existing earthworks/drainage handlers. Example params: trench_length_m=50 m (1–2000), service_spacing_mm=100 mm (50–500), working_space_below_bed_mm=100 mm (0–500). Example call: {"params": {"trench_length_m": 50, "service_spacing_mm": 100, "working_space_below_bed_mm": 100}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | — |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_connection_to_existing Compute Connection to Existing (drainage) BoQ ~431
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Enumerated extra-over connection of a new drainage carrier pipe into an existing asset: existing manhole / inspection chamber, existing sewer or drain (via saddle / wye / cut-in junction), or existing outfall / watercourse / surface system. Routes via CESMM4 I.7.1/2/3 (Class I §I.7 Pipework Ancillaries — Connections), NRM2 33.6.1/2/3, MMHW 500.5.1/2/3 (SHW Cl. 506 Connections to existing sewers, drains and service runs), SMM7 R12.4.1/2/3, with a bore-size digit suffix appended in all four. The connection_type attribute is the discriminator that routes to the right sub-code; the bore digit refines within. Six variant presets cover all three connection types × two characteristic bores. Unit: Nr. Opens the new `drainage_ancillaries` L2 leaf (reserved for ditch, hard-material extra-over, CCTV testing, etc. in future sessions). Sibling assembly: carrier_pipe_run — the S32 pair that delivers a complete tender drainage line. Example params: diameter_mm=225 mm (100–2400). Example call: {"params": {"diameter_mm": 225}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameters for a single connection-to-existing extra-over item. |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_counterfort_wall Compute Counterfort Retaining Wall BoQ ~501
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_cantilever_wall. In-situ reinforced concrete counterfort retaining wall. Discrete RC counterforts on the retained face enhance moment capacity, making the wall economic for 4-10m retained heights (above cantilever-economic range, below anchored-wall range). Includes base slab, thin curtain wall, counterforts at configurable centres, drainage, and backfill. Eight VARIANT_PRESETS exercise the 'one parameter form, eight variants, four standards' moat #1 claim. Routes via wall_type='counterfort' attribute discrimination: CESMM4 F.6.3, NRM2 11.3.3, MMHW 1700.4.2 (SHW Cl. 1704), SMM7 E10.3.2. Example params: stem_height=5 m (3–12), curtain_thickness=0.35 m (0.2–0.6), toe_length=0.6 m (0–3). Example call: {"params": {"stem_height": 5, "curtain_thickness": 0.35, "toe_length": 0.6}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier). Pass `freeboard` (clearance below the wall top, m) instead of the retained-height field to set the retained fill by clearance — the engine back-calculates it as stem − freeboard. Supplying both is rejected.
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| freeboard | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameter form for an in-situ RC counterfort retaining wall. A single dataclass that — through combinations of its fields — produces all eight VARIANT_PRESETS plus arbitrary user-specified geometrie… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_ditch Compute Open Ditch (drainage channel) BoQ ~501
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Linear primary measurement of an open earthwork drainage channel — trapezoidal cross-section, four lining variants (unlined / geotextile / granular / concrete). Routes via CESMM4 Class E.4 (excavation for cuttings), NRM2 Group 34.10 (site works: open drains and ditches), MMHW Series 500.4 (SHW Cl. 514 Earthwork ditches and drains), SMM7 R13.4 (Land Drainage — ditches). Eight variant presets cover all four lining types x two characteristic size scenarios each. Unit: M. Second member of the drainage_ancillaries L2 leaf (opened at S32 with connection_to_existing). 20th use of the classed-then-legacy attribute discrimination pattern via the lining_type discriminator. The four standards genuinely diverge on which work-section heading owns ditches (Class E vs Group 34 vs Series 500 vs R13) — the platform renders all four honestly from one source WorkItem. Example params: run_length_m=100 m (1–1000), top_width_mm=1700 mm (200–10000), bottom_width_mm=500 mm (100–5000). Example call: {"params": {"run_length_m": 100, "top_width_mm": 1700, "bottom_width_mm": 500}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameters for a single open-ditch primary measurement. The geometry is a trapezoidal cross-section run linearly along the ditch alignment. side_slope_h_per_v is the side slope expressed as horizont… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_edge_drain Compute Highway Pavement Edge Drain (HD 33/16) BoQ ~320
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Highway pavement edge drain per HD 33/16. Perforated carrier in a granular-filled trench with filter geotextile wrap; optional top separator under the pavement build-up. Highway-specific defaults: Type B filter aggregate, 200 g/m² geotextile, supported excavation. Headline standard mapping: MMHW 500.7 (filter drain with perforated pipe). Renders cleanly across all four standards with HA 40/01 references. Example params: pipe_internal_diameter_mm=150 mm (80–300), pipe_wall_thickness_mm=25 mm (5–50), drain_length=100 m (1–1000). Example call: {"params": {"pipe_internal_diameter_mm": 150, "pipe_wall_thickness_mm": 25, "drain_length": 100}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | — |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_embankment_cross_section Compute Embankment Cross-Section BoQ ~438
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_end_area_earthworks. Geometry-driven embankment per MMHW Series 600 — trapezoidal cross-section with crest width, asymmetric side slopes (h:v), and per-chainage height profile. Auto-generates the CrossSection series and delegates volume integration + mass-haul + standards routing to the end_area_earthworks engine, inheriting the four-standard rendering invariant. Auto-computes topsoil strip footprint from toe-to-toe envelope and supports an optional founding-strip excavation below ground level. Example params: crest_width_m=10 m (3–30), side_slope_h_per_v=2 (1–4), strip_envelope_offset_m=0.5 m (0–2). Example call: {"params": {"crest_width_m": 10, "side_slope_h_per_v": 2, "strip_envelope_offset_m": 0.5}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Inputs for a geometry-driven embankment cross-section assembly. The assembly generates a `CrossSection` list from the profile + geometry parameters, builds an `EndAreaEarthworksParameters` from the… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_end_area_earthworks Compute End-Area Earthworks BoQ ~515
Free tier. Renders the MMHW standard only — CESMM4, NRM2 and SMM7 require a paid tier. Anonymous callers welcome. Linear earthworks reach measured by the end-area method per MMHW Series 600 — Simpson's Rule with UK-QS even-ordinate trapezoidal-boundary fallback, with full SHW Series 600 Table 6/1 class tagging, mass-haul diagram (bulking + shrinkage per SHW Cl. 605), cut/fill balance, DISPOSAL vs FILL_GENERAL routing, capping and sub-base build-up, and topsoil strip + replacement. Renders identically across CESMM4 / NRM2 / MMHW / SMM7 with per-class line distinction. Example params: unacceptable_proportion=0 (0–1), topsoil_strip_depth_m=0.15 m (0–1), topsoil_replace_depth_mm=150 mm (0–500). Example call: {"params": {"unacceptable_proportion": 0, "topsoil_strip_depth_m": 0.15, "topsoil_replace_depth_mm": 150}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Inputs for a linear earthworks reach measured by the end-area method. The five area streams in each `CrossSection` are integrated independently along the chainage axis. `topsoil_strip_area` is the p… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_flexible_pavement Compute Flexible (Bituminous) Pavement Build-Up BoQ ~462
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_end_area_earthworks. Flexible pavement build-up: optional capping (Class 6F) + Type 1 (Class 1A) granular sub-base + asphalt concrete base (AC) + binder course (AC/HRA) + optional tack coat + surface course (AC/HRA/SMA/TSCS). Routes the bound layers through PAVEMENT_BASE/BINDER/SURFACE handlers with pavement_family discrimination across all four standards. Sub-base and capping route through the v8 FILL_SUB_BASE/FILL_CAPPING SHW-class-aware handlers. Four traffic-category defaults (domestic/light/medium/heavy) per DMRB CD 226. All four standards render (CESMM4 R.1-R.4, NRM2 34.4-34.6, MMHW 700, SMM7 Q20+Q22). Example params: length=100 m (0.5–2000), width=6 m (0.5–30), sub_base_thickness_mm=150 mm (100–500). Example call: {"params": {"length": 100, "width": 6, "sub_base_thickness_mm": 150}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Input parameters for a flexible pavement assembly. Geometric defaults match a 100m × 6m urban access road (medium traffic) per DMRB CD 226 starting build-up: 150mm Type 1 sub-base, 150mm AC 32 base,… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_french_drain Compute French (Filter) Drain BoQ ~308
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Perforated land drain in a granular-filled trench with non-woven filter geotextile wrap. Composes the bedding primitive at Class S geometry (full granular envelope) with three additions: perforated carrier, filter geotextile wrap, and optional top seal. Renders cleanly across CESMM4 / NRM2 / MMHW (Series 500 filter drain) and SMM7. Example params: pipe_internal_diameter_mm=150 mm (80–600), pipe_wall_thickness_mm=25 mm (5–80), drain_length=50 m (1–500). Example call: {"params": {"pipe_internal_diameter_mm": 150, "pipe_wall_thickness_mm": 25, "drain_length": 50}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | — |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_gabion_wall Compute Gabion Retaining Wall BoQ ~654
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_cantilever_wall. Modular gabion retaining wall built from welded or hexagonal-mesh wire baskets filled with hard angular graded stone (SHW Cl. 622). The first non-concrete retaining structure in the platform and the FIRST member of the earth_structures L1 leaf — opening Phase E. Spans four structural forms via the gabion_form discriminator: STACKED_RECTANGULAR (standard highway boundary), STACKED_STEPPED (architectural / heritage), BATTERED (tall walls with back batter), and FACING_MATTRESS (Reno-type mattresses for slope facing / scour protection). Eight variant presets exercise the parameter form covering all four gabion_form values: highway boundary, landscape, stepped front, heritage stepped, battered, river training, scour apron, and tall battered. Routes via three new WorkCategory entries (GABION_BASKET, GABION_FACING_MATTRESS, STONE_FILL) — the first session where the classed-then-legacy discriminator pattern is applied to fundamentally new measurement vocabulary rather than to existing concrete categories. Codes: CESMM4 E.8.1-3 (Class E — Earthworks), NRM2 5.20-22 (Group 5 — Excavating and filling), MMHW 600.12-14 (Series 600 — Earthworks; SHW Cl. 622/623), and SMM7 D41.1/D41.2/D20.20 (D41 — Crib walls / gabions / reinforced earth — the only standard with a NAMED home). 16th use of the discriminator pattern, first applied to new WorkCategories rather than legacy ones. Example params: wall_height=3 m (0.1–8), wall_length=25 m (5–200), basket_length_m=2 m (1–3). Example call: {"params": {"wall_height": 3, "wall_length": 25, "basket_length_m": 2}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the…
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameter form for a gabion retaining wall. A single dataclass that — through combinations of its fields and the ``gabion_form`` discriminator — produces all eight VARIANT_PRESETS plus arbitrary use… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_gravity_wall Compute Mass Concrete Gravity Retaining Wall BoQ ~558
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_cantilever_wall. In-situ mass concrete gravity retaining wall (typical C20/25 to C25/30) with trapezoidal cross-section, retaining soil by self-weight rather than structural action. Eight variant presets exercise the parameter form — landscape, highway boundary, trapezoidal, stepped-front, toe-projection, keyed-base, stepped-foundation, and battered-back-vertical-front. Routes via wall_type='gravity' attribute discrimination through CESMM4 F.5.3, NRM2 11.2.3, MMHW 1700.5 (SHW Cl. 1704 structural concrete), and SMM7 E10.2.3. Reinforcement default zero (gravity walls are nominally unreinforced); optional nominal face mesh available via nominal_face_reinforcement_kg_per_m3 parameter. Includes excavation (battered or supported, level or stepped foundation), blinding, drainage system (subsoil drain + granular surround + geotextile separator), Class 6N backfill, disposal, and formwork to vertical and battered faces. 13th use of the classed-then-legacy attribute discrimination pattern, and first use in the retaining wall family — opening the wall moat for subsequent counterfort (S30), anchored (S31) and bored pile (S32) variants. Example params: stem_height=3 m (1.5–6), stem_thickness_top=0.4 m (0.2–1), stem_thickness_bottom=1.3 m (0.4–2.5). Example call: {"params": {"stem_height": 3, "stem_thickness_top": 0.4, "stem_thickness_bottom": 1.3}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameter form for a mass concrete gravity retaining wall. A single dataclass that — through combinations of its fields — produces all eight VARIANT_PRESETS plus arbitrary user-specified geometries.… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_gully Compute Highway / Curtilage Gully with Connection BoQ ~311
Free tier. Renders the MMHW standard only — CESMM4, NRM2 and SMM7 require a paid tier. Anonymous callers welcome. Composite drainage inlet: precast gully pot with trap, ductile-iron grating, optional kerb outlet, and a short connection drain to the carrier sewer. The connection drain re-uses the bedding primitive. Four-standard rendering with component-aware sub-codes (CESMM4 K.6.x, NRM2 33.8.x, MMHW 500.7.x, SMM7 R12.3.6.x). Example params: pot_internal_diameter_mm=450 mm (300–750), pot_depth_m=0.9 m (0.45–2.5), pot_wall_thickness_mm=60 mm (50–100). Example call: {"params": {"pot_internal_diameter_mm": 450, "pot_depth_m": 0.9, "pot_wall_thickness_mm": 60}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | — |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_hard_material_in_trench Compute Hard Material in Trench (extra-over) BoQ ~753
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Linear extra-over measurement of hard material encountered during drainage trench excavation. Discriminates between natural rock (CESMM4 E.6 / NRM2 5.6.1 / MMHW 500.6.1 / SMM7 R12.6.1) and artificial hard material — buried concrete / masonry / obstructions (CESMM4 E.7 / NRM2 5.6.2 / MMHW 500.6.2 / SMM7 R12.6.2). The platform's first dual-quantity WorkItem: carries both length_m and volume_m3 so CESMM4/NRM2 (m³) and MMHW/SMM7 (m) each render with their correct unit per the standards' rules. Eight variant presets cover both hard-material types × four depth bands. SMM7 R12 deems trench excavation (including hard material) included in the pipe-run rate — the SMM7 handler emits a zero-priceable annotated line for tender transparency (third use of the deemed-included extra-over annotation pattern). Closes the drainage_ancillaries L2 leaf at 4/4 members. Sibling assemblies: connection_to_existing (S32), ditch (S33), pipework_testing (S33). Example params: length_m=10 m (0.5–500), max_depth_m=1.5 m (0.3–10), trench_width_m=0.7 m (0.3–3). Example call: {"params": {"length_m": 10, "max_depth_m": 1.5, "trench_width_m": 0.7}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameters for a single hard-material extra-over scenario. Geometry interpretation: - `length_m` is the chainage extent of the hard-material zone (i.e. how many metres of pipe-run encounter ha… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_headwall Compute Reinforced Concrete Outfall Headwall BoQ ~302
Free tier. Renders the MMHW standard only — CESMM4, NRM2 and SMM7 require a paid tier. Anonymous callers welcome. Composite RC outfall headwall: back wall pierced by the outfall pipe, splayed wing walls flaring downstream, apron slab, and rock-armour scour protection. In-situ or precast construction; BS 8666:2020 bar schedule composed across back wall, apron and wing walls. Four-standard rendering across CESMM4 / NRM2 / MMHW / SMM7. Example params: pipe_internal_diameter_mm=300 mm (100–1800), pipe_wall_thickness_mm=50 mm (15–120), invert_below_apron_m=0 m (0–1.5). Example call: {"params": {"pipe_internal_diameter_mm": 300, "pipe_wall_thickness_mm": 50, "invert_below_apron_m": 0}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | — |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_headwall_attenuation_outlet Compute Headwall — Attenuation Outlet BoQ ~422
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_headwall. Controlled attenuation outlet: precast concrete headwall plus outlet-control ironmongery (orifice plate, optional flap valve, weir overflow, penstock) and downstream scour protection. 2nd use of the bundle-with-shared-envelope pattern (template: combined_services_trench S14). Composes headwall_precast for the structural unit and bedding; emits ironmongery items as CONTRACTOR_INSTALL_PC_SUPPLY by default (3rd commercially significant PC-supply emitter after utility_chamber and utility_kiosk_base). Scour protection extended to three variants: rock armour, gabion mattress, concrete apron. Example params: orifice_diameter_mm=150 mm (20–600), orifice_target_discharge_ls=5 l/s (0.1–200), flap_valve_size_mm=0 mm (0–1200). Example call: {"params": {"orifice_diameter_mm": 150, "orifice_target_discharge_ls": 5, "flap_valve_size_mm": 0}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameter form for an attenuation outlet headwall. Composes a precast headwall (size, bedding) with one always-present orifice plate and up to three optional outlet-control ironmongery items (flap v… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_headwall_precast Compute Precast Concrete Outfall Headwall BoQ ~419
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_headwall. Precast concrete outfall headwall, supplied as a whole unit from a UK manufacturer (Marshalls CPM, FP McCann, Stanton Bonna or equivalent). Catalogue-driven sizing from PHW_300 (300mm pipe ID) to PHW_1500 (1500mm). Includes excavation, concrete or granular bedding, and optional rock-armour scour protection. Routes precast unit through CESMM4 Class H, NRM2 33.9.1, MMHW 500.8.1 (SHW Cl. 511), and SMM7 R12.3.7 via headwall_type=precast attribute discrimination. Example params: bedding_thickness_mm=150 mm (75–300), bedding_overhang_m=0.15 m (0.075–0.3), working_space_each_side_m=0.45 m (0.3–1.5). Example call: {"params": {"bedding_thickness_mm": 150, "bedding_overhang_m": 0.15, "working_space_each_side_m": 0.45}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameter form for a precast headwall. Catalogue-driven: pick a `size` and the unit's nominal physical dimensions are read from `_CATALOGUE`. Override individual physical fields if a specific manufa… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_highway_drainage_channel Compute Highway Drainage Channel BoQ ~643
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_end_area_earthworks. Highway / surface-water drainage channel installation per BS EN 1433 + SHW Cl. 511-514 + HD 33/16. Discriminates between five UK channel product classifications via the channel_type enum (linear_polymer_concrete — ACO-pattern; linear_concrete — Charcon-pattern precast; slot_drain — narrow-slot recessed; combined_kerb_drainage — Beany/Safeticurb integrated unit per SHW Cl. 514; steel_grated_channel — heavy-duty stainless/galvanised). Plus parallel discriminators on two further WorkCategory entries: outfall_type on CHANNEL_OUTFALL (end / branch / side), silt_box_type on CHANNEL_SILT_BOX (standard / heavy-duty / deep-sump). The MMHW Series 500 _highway_drainage_channel handler is the platform's FOURTH 2D-banded handler — code `500.8.{t}.{d}` bands by channel_type (5 bands) AND depth_class (4 bands). 5×4 = 20-cell grid. SMM7 routes to R12 (Drainage below ground) — SECOND highway L1 family outside Section Q after S39 lighting → V41. Example params: channel_depth_mm=100 mm (50–1500), channel_length_m=50 m (1–500), outfall_count=1 nr (0–20). Example call: {"params": {"channel_depth_mm": 100, "channel_length_m": 50, "outfall_count": 1}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Inputs for the highway_drainage_channel assembly. Required: channel_type — ChannelType enum (or string equivalent) depth_class — DepthClass enum (or string) channel_depth_… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_kerb_run Compute Precast Concrete Kerb Run BoQ ~420
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_cantilever_wall. Linear precast concrete kerb run on concrete bed and haunch over Type 1 (Class 1A) granular sub-base. Emits excavation, sub-base (v8 SHW-class-aware), concrete bed, kerb units to BS EN 1340 / SHW Cl. 1101, concrete haunch to back face, optional channel block, and disposal. Supports HB2/HB1/SP/BN/EF/ER kerb profiles and CS1/CS2/dish channels. All four standards render with type designators (CESMM4 R.7, NRM2 34.10, MMHW 1100, SMM7 Q10). Example params: kerb_length=25 m (1–1000), bed_thickness_mm=150 mm (75–300), bed_extra_each_side_mm=100 mm (0–300). Example call: {"params": {"kerb_length": 25, "bed_thickness_mm": 150, "bed_extra_each_side_mm": 100}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Input parameters for a kerb run assembly. Geometric defaults match a standard UK HB2 road kerb on 150mm concrete bed over 150mm Type 1 sub-base, with triangular haunch rising to half the kerb height… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_lighting_column Compute Lighting Column BoQ ~488
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_end_area_earthworks. Highway / street lighting column installation per BS EN 40 + BS 5489-1:2020 + TR 22. Discriminates between four UK column material classifications via the column_type enum (steel_galvanised, aluminium, composite_grp, decorative_cast_iron). Plus parallel discriminators on three further WorkCategory entries: foundation_type on COLUMN_FOUNDATION, luminaire_type on LUMINAIRE, bracket_type on COLUMN_BRACKET. The MMHW Series 1300 _lighting_column handler is the platform's THIRD 2D-banded handler — code `1300.4.1.{h}.{c}` bands by column_height_class (6 bands per TR 22) AND column_loading_class (4 bands per BS EN 40-3). 6×4 = 24-cell grid (the LARGEST banded grid in the platform). Example params: mounting_height_m=6 m (4–16), luminaire_wattage_W=60 W (10–1000), bracket_count=0 Nr (0–4). Example call: {"params": {"mounting_height_m": 6, "luminaire_wattage_W": 60, "bracket_count": 0}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Inputs for the lighting_column assembly. Defaults anchored to URBAN_6M_LED — UK urban distributor: 6 m steel galvanised column on precast socket, BS EN 40-3 Class B, LED M-class luminaire (~60 W typ… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_manhole Compute Precast Concrete Circular Manhole BoQ ~298
Free tier. Renders the MMHW standard only — CESMM4, NRM2 and SMM7 require a paid tier. Anonymous callers welcome. Composite assembly: precast concrete circular manhole with base slab, chamber rings (optional reducing slab + shaft), cover slab, frame & cover (BS EN 124 loading classes), step irons or ladder, in-situ benching with pre-formed channel, granular surround, geotextile separator, and excavation. Supports both open-battered and sheet-piled excavations. Example params: internal_diameter=1.5 m (1–3), wall_thickness=0.15 m (0.1–0.25), invert_depth=3.5 m (0.5–12). Example call: {"params": {"internal_diameter": 1.5, "wall_thickness": 0.15, "invert_depth": 3.5}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | — |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_manhole_precast Compute Precast Concrete Monolithic Manhole BoQ ~476
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Fully monolithic precast concrete circular manhole comprising factory-cast base + bottom ring + integral benching + pre-formed channel as a single delivered unit (BS 5911-3), with stacked precast chamber rings, optional reducing slab and access shaft, precast cover slab, ductile-iron frame and cover (BS EN 124 loading classes), step irons cast into rings, granular or concrete bedding, granular surround, geotextile separator, and excavation. Catalogue-driven sizing from PMC_1200 (1200mm ID) to PMC_2400 (2400mm ID). Routes via manhole_type=precast_monolithic attribute discrimination through CESMM4 Class K.1.2.x, NRM2 33.7.5, MMHW 500.5.5-.8 (SHW Cl. 507), and SMM7 R12.3.1.x. Example params: invert_depth=3.5 m (0.5–12), bedding_thickness_mm=150 mm (100–300), bedding_overhang_m=0.15 m (0.1–0.3). Example call: {"params": {"invert_depth": 3.5, "bedding_thickness_mm": 150, "bedding_overhang_m": 0.15}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameter form for a fully monolithic precast concrete manhole. Catalogue-driven: pick a ``size`` and the chamber's nominal dimensions, masses, and ring heights are read from ``_CATALOGUE``. Overrid… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_multi_section_assembly Compute multi-section assembly BoQ ~235
Compute one sectioned/linear assembly across multiple sections in a single call and return a combined Bill of Quantities plus per-section results. Each section sets its own run_length and geometry; shared_params apply to all sections. Use for a wall, kerb run, drain or barrier that changes along its length. assembly_slug must be a sectioned assembly (e.g. cantilever_wall, kerb_run, edge_drain); non-linear items return INVALID_INPUT. Free tier: MMHW only, each section consumes one daily slot. Example: {"assembly_slug":"cantilever_wall","standard":"MMHW","sections":[{"label":"Bay 1","run_length":20,"stem_height":1.5},{"label":"Bay 2","run_length":15,"stem_height":2.4}]}.
| Name | Type | Req | Description |
|---|---|---|---|
| aggregate_boq | boolean | — | — |
| assembly_slug | string | yes | — |
| deliverables | — | — | — |
| include_backup | boolean | — | — |
| include_section_boq | boolean | — | — |
| sections | array | yes | — |
| shared_params | — | — | — |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_pad_foundation Compute Concrete Pad Foundation BoQ ~247
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_cantilever_wall. Single isolated reinforced concrete pad foundation with optional pedestal. Demonstrates BS 8666:2020 reinforcement scheduling integrated with the four-standard rendering invariant. Example params: length=2 m (0.5–10), width=2 m (0.5–10), thickness=0.45 m (0.15–2). Example call: {"params": {"length": 2, "width": 2, "thickness": 0.45}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | — |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_parapet Compute Parapet (Bridge / Structural Deck) BoQ ~659
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_end_area_earthworks. Bridge / structural-deck parapet installation per BS 6779-1 + BS EN 1317-2 + SHW Cl. 408. Discriminates between four UK parapet system classifications via the parapet_type enum (pedestrian_only per BS 7818; vehicle_p1_p2 — low-containment BS EN 1317-2; vehicle_h1_h2_h3 — higher-containment; combined_pedestrian_vehicle — composite design). Plus parallel discriminators on two further WorkCategory entries: same parapet_type on PARAPET_POST, transition_type on PARAPET_TRANSITION (to_vrs / to_abutment / expansion_joint). The MMHW Series 400 _parapet handler is the platform's SEVENTH 1D-banded handler — code `400.4.1.{c}` bands by containment_level (4 bands per BS EN 1317-2). 1D choice is disciplined — second principled rejection of forced 2D banding (after S38 road_marking). LAUNCH-COMPLETING 45TH ASSEMBLY — opens highway_bridge_edge L2 leaf, closing the highway suite at 5/5 populated leaves and the platform at 45/45 launch target. SMM7 routes BACK to Q40 (sibling slot to VRS at Q40.5) — preserves UK trade reality. Example params: parapet_height_mm=1100 mm (900–1800), parapet_length_m=25 m (1–2000), post_count=0 Nr (0–200). Example call: {"params": {"parapet_height_mm": 1100, "parapet_length_m": 25, "post_count": 0}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Inputs for the parapet assembly. Required: parapet_type — ParapetType enum (or string equivalent) containment_level — ContainmentLevel enum (or string) parapet_height_mm — nominal p… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_permeable_pavement Compute Permeable Pavement (CIRIA C753 SuDS) BoQ ~522
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_end_area_earthworks. Permeable pavement build-up per CIRIA C753 — The SuDS Manual Chapter 20. Covers the three principal UK permeable surface types (Permeable Block Paving per BS 7533-13; Porous Asphalt per SHW Cl. 938; Porous no-fines Concrete per CIRIA C753) and the three CIRIA infiltration regimes (System A full infiltration; System B partial / sides-tanked; System C no infiltration / fully tanked). Emits excavation + formation prep + tanking liner (Systems B/C) + geotextile separator + Class 3 open-graded reservoir sub-base + laying course (PBP) + permeable surface + perforated outlet pipe (Systems B/C) + disposal. Routes the reservoir sub-base, the tanking liner, and the permeable surface through three parallel classed-then-legacy discriminators (is_reservoir_sub_base, is_pavement_tanking, pavement_family) across all four standards. SMM7 PBP routes to Q25 (block pavings — different trade) while PA/PC stay at Q22 (asphalt trade) — UK trade-boundary platform principle. First launch-class assembly built entirely on existing WorkCategory vocabulary. Example params: length=12 m (0.5–500), width=5 m (0.5–100), reservoir_thickness_mm=350 mm (150–1000). Example call: {"params": {"length": 12, "width": 5, "reservoir_thickness_mm": 350}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Input parameters for a permeable pavement assembly. Geometric defaults match a 12m × 5m residential drive with PBP surface and System A (full infiltration) — the dominant UK small-civils SuDS use ca… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_petrol_oil_interceptor Compute Prefabricated Petrol/Oil Interceptor (Separator) BoQ ~594
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Prefabricated petrol/oil interceptor (separator) per BS EN 858-1:2002 / BS EN 858-2:2003 and SHW Cl. 519. Catalogue-driven on three axes: Class (1 with coalescer + auto-closure for ≤5 mg/l surface-water discharge, or 2 for ≤100 mg/l foul-sewer discharge), Type (full retention NSF for high-spill-risk forecourts, or bypass NSB for low-spill-risk car parks), and Nominal Size (NS3 to NS100 l/s flow rating — 7 catalogue entries). Composite of the procured interceptor unit (Nr, default supply route CONTRACTOR_INSTALL_PC_SUPPLY for engineer-specified prefab), concrete blinding bedding, granular surround per SHW Cl. 803, geotextile separator, and foundation excavation with optional sheet pile support. Oil storage capacity derived per BS EN 858-2 cl. 4.3.6 (V = NS×10 for full retention, NSB×15 for bypass). Opens drainage_treatment leaf; the canonical pre-treatment for hot-spot catchments draining to soakaway, watercourse, or foul sewer. Routes via CESMM4 K.5.x.n (size-banded), NRM2 33.9.x, MMHW 500.13.x (SHW Cl. 519), SMM7 R12.5.x. Example params: bedding_blinding_thickness_mm=150 mm (100–300), bedding_overhang_m=0.3 m (0.15–0.5), surround_thickness_each_side_m=0.3 m (0.15–0.5). Example call: {"params": {"bedding_blinding_thickness_mm": 150, "bedding_overhang_m": 0.3, "surround_thickness_each_side_m": 0.3}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameter form for a petrol/oil interceptor installation. Catalogue-driven on three axes: size (NS rating, catalogue lookup for dimensions/mass/silt), class (performance — CLASS_1/CLASS_2), and type… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_pipe_bedding Compute Pipe Bedding and Surround BoQ ~318
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Linear pipe trench with class-driven bedding and surround. Strategy pattern on (BeddingContext × BeddingClass): Highway (HA 40/01 / MMHW Series 500) vs Building (BS EN 1610 / NRM2 §33), Class N/F/B/S/A/Z. Emits trench excavation, granular bed, surround or concrete cradle/encasement, selected backfill, disposal and pipework. All four standards render with class and clause references. Example params: pipe_internal_diameter_mm=300 mm (100–1800), pipe_wall_thickness_mm=50 mm (10–200), pipe_length=25 m (1–500). Example call: {"params": {"pipe_internal_diameter_mm": 300, "pipe_wall_thickness_mm": 50, "pipe_length": 25}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | — |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_pipework_testing Compute Pipework Testing (drainage) BoQ ~396
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Linear measurement of testing on new drainage pipework — CCTV survey, air pressure test, water pressure test, or mandrel pull-through. Routes via CESMM4 Class I §I.8 (Tests on new pipework), NRM2 Group 33.18 (Testing of drainage) as priceable lines; via MMHW Series 500.7 (per SHW Cl. 507 deemed included in pipe-run rate) and SMM7 R12.7 (R12 coverage rules deemed included) as zero-priceable annotated lines for tender transparency. Introduces the platform's third named maturity pattern: deemed-included extra-over annotation (joining classed-then-legacy and declared-then-banded). Eight variant presets cover all four test methods x two bore scenarios each. Unit: M. Third member of the drainage_ancillaries L2 leaf. 21st use of the discriminator pattern via test_method. Example params: length_tested_m=100 m (1–2000), diameter_mm=225 mm (100–2400). Example call: {"params": {"length_tested_m": 100, "diameter_mm": 225}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameters for a single pipework testing measurement. |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_reinforced_soil_wall Compute Reinforced Soil Wall (RSW) BoQ ~703
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_cantilever_wall. Reinforced soil retaining wall (RSW) using granular fill reinforced with horizontal layers of geogrid or steel tie strips, with one of four facing systems: precast concrete panels (Reinforced Earth™ / VSL Retained Earth style), segmental modular blocks (Allan Block / Keystone), wraparound soft face (vegetated or biodegradable mat), or Terramesh-style steel mesh face (re-using the S29 gabion vocabulary). The SECOND member of the earth_structures L1 leaf (after gabion_wall at S29), the SIXTH member of the wall family, the FIFTH structural system, and the FIRST wall family member with a face-area-primary measurement basis (m² of face + m² × layers of geogrid, both m²; every prior wall body was m³). 17th use of the classed-then-legacy attribute discrimination pattern. Routes via four new WorkCategory entries (RSW_FACING_PANEL, RSW_MODULAR_BLOCK, RSW_WRAPAROUND_FACE, RSW_TIE_STRIP) plus the GEOGRID category (whose handler is gap-filled in CESMM4/NRM2/MMHW this session) plus re-use of GABION_BASKET on the STEEL_MESH_FACE variant. Codes: CESMM4 E.8.4-8 (Class E Earthworks §E.8 stabilisation), NRM2 5.23-27 (Group 5 Excavating and filling), MMHW 600.15-19 (Series 600 Earthworks; SHW Cl. 624 reinforced earth retaining structures), and SMM7 D41.3/D41.4/D41.5/D20.21/D20.14.2 (D41 — Crib walls / gabions / REINFORCED EARTH — the NAMED home, now serving TWO wall families). Eight variant presets exercise all four RSWFacing values (2/2/2/2 split). Example params: wall_height=6 m (0.5–12), wall_length=40 m (5–200), depth_into_fill_m=4.5 m (0.35–15). Example call: {"params": {"wall_height": 6, "wall_length": 40, "depth_into_fill_m": 4.5}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-s…
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameter form for a reinforced soil wall. A single dataclass that — through combinations of its fields and the ``rsw_facing`` discriminator — produces all eight VARIANT_PRESETS plus arbitrary user-… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_rigid_pavement Compute Rigid (Concrete) Pavement Build-Up BoQ ~506
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_end_area_earthworks. Rigid pavement build-up: optional capping (Class 6F) + Type 1 (Class 1A) granular sub-base + optional separation membrane + PQC slab (URC, JRC, or CRCP variant) with joint formwork (transverse contraction, longitudinal construction, expansion) and reinforcement (dowel bars + tie bars + optional fabric mesh for JRC, continuous longitudinal for CRCP). Routes the slab and its joints/reinforcement through the v12 is_pavement_slab discrimination to pavement-specific codes across all four standards (CESMM4 Class R, NRM2 Group 34.7, MMHW Series 1000, SMM7 Q21). Sub-base and capping route through the v8 FILL_SUB_BASE/FILL_CAPPING SHW-class-aware handlers. Three pavement-type defaults (URC/JRC/CRCP) per DMRB CD 226. Reinforcement scheduled per BS 8666:2020 (shape 00 dowels and tie bars; mass-only mesh and CRCP continuous). Example params: length=50 m (0.5–2000), width=7 m (0.5–30), sub_base_thickness_mm=150 mm (100–500). Example call: {"params": {"length": 50, "width": 7, "sub_base_thickness_mm": 150}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Input parameters for a rigid pavement assembly. Defaults: 50m × 7m urban distributor — JRC with 25m bay length, 230mm slab on 150mm Type 1 sub-base, A393 mesh mid-depth. Tie bars at 3.5m lane bounda… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_road_marking Compute Road Marking BoQ ~1,089
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_end_area_earthworks. Road marking installation per SHW Cl. 1207-1215 and TSRGD 2016. Discriminates between five UK marking-line classifications via the marking_line_type enum: continuous, broken_short, broken_long, double_continuous, lane_line. Plus parallel discriminators on three further WorkCategory entries: area_marking_type on ROAD_MARKING_AREA, symbol_type on ROAD_MARKING_SYMBOL, and stud_type on ROAD_STUD. THIRD member of the highway L1 leaf (after S36 VRS, S37 traffic_sign) and SECOND member of the highway_signs_markings L2 leaf — 42nd assembly. The highway_signs_markings L2 leaf becomes the first L2 leaf in the highway L1 to reach 2 members. Five variant presets cover the principal UK commercial scenarios: urban continuous white line, rural broken centreline with hazard, motorway hatched chevron, junction give-way with triangle, and motorway lane line with studs. Routes via four new WorkCategory entries (ROAD_MARKING_LINE, ROAD_MARKING_AREA, ROAD_MARKING_SYMBOL, ROAD_STUD). Codes: CESMM4 X.5 (Class X §5 — road markings), NRM2 34.9 (Site works — markings), MMHW 1200.1.{w} (Series 1200 — Traffic Signs and Road Markings, with 1D banding by line_width_class), SMM7 Q40.7 (Section Q40 — Fencing/site furniture). 26th use of classed-then-legacy attribute discrimination pattern; 7th use of declared-then-banded (remains 1D — material rejected as a banding axis). Broadest unit-mix in any single CivilQuants assembly: m of line + m² of area + nr of symbol + nr of stud. Example params: actual_line_width_mm=100 mm (50–450), line_length_m=200 m (0–10000), secondary_line_length_m=0 m (0–10000). Example call: {"params": {"actual_line_width_mm": 100, "line_length_m": 200, "secondary_line_length_m": 0}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverable…
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameters for a single road marking installation. Defaults anchored to URBAN_CONTINUOUS_WHITE_LINE — 200 m of continuous 100 mm thermoplastic edge/centre line. Required-field defaults added per G.6… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_single_service_run Compute Single Service Run BoQ ~474
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Single-service utility run per NJUG Volume 1 — one water main OR one gas main OR one electricity cable duct OR one telecoms duct (or fibre / street-lighting / HV cable duct) in a dedicated trench. Wraps the combined-services-trench engine with a single-band envelope and re-tags emissions back to this assembly. Renders through CESMM4 Class I / NRM2 Group 41 / MMHW Series 1300 / SMM7 Group T (services) on top of the shared earthworks / drainage handlers (excavation, disposal, bedding, surround, fill, tape). Example params: bedding_thickness_m=0.1 m (0.05–0.3), surround_above_crown_m=0.15 m (0–0.5), trench_length_m=50 m (1–1000). Example call: {"params": {"bedding_thickness_m": 0.1, "surround_above_crown_m": 0.15, "trench_length_m": 50}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameters for a single-service utility run. Maps neatly to a one-column UI form: the user picks a service type from a dropdown, optionally tweaks cover/OD/material, sets length and trench width, an… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_soakaway Compute Infiltration Soakaway (CIRIA C753) BoQ ~944
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_attenuation_tank. Infiltration soakaway per CIRIA C753 Chapter 25. Granular-fill or modular-crate storage envelope with infiltration discharge through the base and side walls. Wraps attenuation_tank for the storage envelope and emits an INFILTRATION_SURFACE item plus optional PERFORATED_DISTRIBUTION_PIPE on top. Includes the C753 rational-method sizing engine with hot-spot and cold-spot factors of safety per C753 Tables 25.4 / 25.5; the engine refuses to size for VERY_HIGH hot-spot catchments (fuel forecourts, lorry parks) which C753 prohibits from direct infiltration without pre-treatment. Half-emptying time checked against the 24h C753 §25.4 limit. Renders cleanly across CESMM4 / NRM2 / MMHW / SMM7 using existing earthworks / drainage handlers plus the two new categories (INFILTRATION_SURFACE, PERFORATED_DISTRIBUTION_PIPE) added in S22. Example params: catchment_area_m2=500 m² (10–10000), rainfall_depth_mm=60 mm (10–300), measured_infiltration_rate_m_per_s=0.0001 m/s (1e-07–0.01). Example call: {"params": {"catchment_area_m2": 500, "rainfall_depth_mm": 60, "measured_infiltration_rate_m_per_s": 0.0001}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameters for a CIRIA C753 infiltration soakaway. Two ways to specify the design storm: (a) ``design_storm_volume_m3`` directly (from an upstream MicroDrainage / InfoWorks ICM model) — pre… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_soil_nailed_slope Compute Soil-Nailed Slope BoQ ~915
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_cantilever_wall. Cut slope stabilised by passively-stressed soil nails with an applied face system. Discriminates between four face systems via the face_system enum: SHOTCRETE_MESH (dominant UK highway-cutting choice per SHW Cl. 644), HARD_FACING_PANEL (premium permanent works), FLEXIBLE_MESH (weathered rock drape), and VEGETATED_GEOGRID (landscape-sensitive schemes). Third member of the earth_structures L1 leaf (after gabion_wall S29 and reinforced_soil_wall S30). Eight variant presets cover all four face systems × representative slope geometries. Routes via three new WorkCategory entries (SOIL_NAIL, SHOTCRETE_FACE, FACE_MESH_REINFORCEMENT) plus reuse of EXCAVATION_GENERAL, DISPOSAL, CONCRETE_REINFORCED, GEOTEXTILE_FILTER, GEOGRID, and TOPSOIL_PLACE. Codes: CESMM4 C.5.X (soil nail) + E.8.10 (shotcrete) + G.5.8 (mesh), NRM2 7.7.X + 5.28.1 + 11.6.1, MMHW 600.20.X + 600.21.1 + 600.22.1 (SHW Cl. 638-639 / Cl. 644), SMM7 D32.3.X (steel piling — soil nails) + D41.6/D41.7 (the NAMED home for the three earth-structures families now). 23rd use of the classed-then-legacy attribute discrimination pattern; 4th use of the declared-then-banded pattern (nail_length_m bands the C.5.X / 7.7.X / 600.20.X / D32.3.X third digit). Example params: slope_height_m=8 m (0.5–25), slope_angle_deg=65 ° (10–89), slope_length_m=30 m (2–500). Example call: {"params": {"slope_height_m": 8, "slope_angle_deg": 65, "slope_length_m": 30}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameters for a single soil-nailed slope. Geometry interpretation: - ``slope_height_m`` is the vertical extent of the cut slope (top of crest to toe of slope). - ``slope_angle_deg`` is the… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_strip_foundation Compute Concrete Strip Foundation BoQ ~356
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_cantilever_wall. Linear reinforced concrete strip foundation, level or stepped. Closes the P1 launch set alongside pad_foundation. Integrates BS 8666:2020 reinforcement scheduling. Stepping is the v10 demonstration of cross-cutting standards-handler discrimination. Example params: length=10 m (1–100), width=0.75 m (0.3–2.5), thickness=0.35 m (0.15–1.5). Example call: {"params": {"length": 10, "width": 0.75, "thickness": 0.35}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameters for the strip foundation assembly. Defaults are tuned to a typical UK domestic / light commercial strip: 750mm wide, 350mm deep, 10m long, founded ~700mm below GL on 75mm blinding. Reinfo… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_swale Compute SuDS Swale (CIRIA C753) BoQ ~359
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_attenuation_tank. Vegetated, geotextile-reinforced or rip-rap-lined linear drainage swale per CIRIA C753. Trapezoidal prismatic channel with three lining strategies covering the UK design palette from low-velocity amenity grass channels (1V:3H, 1-3% gradient) to high-velocity rip-rap-lined stretches. Optional check-dams (stone or concrete) for steeper sections. Renders cleanly across all four standards using existing earthworks / geosynthetics / concrete handlers — no PC items, all contractor-full supply route. Example params: bed_width=0.5 m (0.2–3), left_side_slope_h_per_v=3 (1.5–6), right_side_slope_h_per_v=3 (1.5–6). Example call: {"params": {"bed_width": 0.5, "left_side_slope_h_per_v": 3, "right_side_slope_h_per_v": 3}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | — |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_traffic_sign Compute Traffic Sign BoQ ~796
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_end_area_earthworks. Traffic sign installation per SHW Cl. 1201-1206 and TSRGD 2016. Discriminates between five TSRGD sign classifications via the sign_type enum: warning triangular, regulatory circular, regulatory rectangular, directional rectangular, and information rectangular. SECOND member of the highway L1 leaf (after S36 VRS) and FIRST member of the highway_signs_markings L2 leaf — 41st assembly. Five variant presets cover the principal UK commercial scenarios: rural warning triangle on single post, urban regulatory circular, rural advance directional on twin posts, motorway gantry ADS, and urban information rectangle. Routes via three new WorkCategory entries (TRAFFIC_SIGN_POST, TRAFFIC_SIGN_FACE, SIGN_FOUNDATION). Codes: CESMM4 X.4 (Class X §4 — traffic signs), NRM2 34.8 (Site works — signs), MMHW 1300.1.{a}.{h} (Series 1300 — Road Lighting/Traffic Signs/Bollards, with 2D banding by face_area × mounting_height), SMM7 Q40.6 (Section Q40 — Fencing/site furniture). 25th use of classed-then-legacy attribute discrimination pattern; 6th use of declared-then-banded AND the SECOND 2D-banded handler (MMHW 1300.1.{a}.{h} bands by both axes simultaneously). Example params: post_length_m=3 m (1.5–12), post_count=1 Nr (1–4), faces=1 Nr (1–6). Example call: {"params": {"post_length_m": 3, "post_count": 1, "faces": 1}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameters for a single traffic sign installation. Geometry interpretation: - ``post_length_m`` is the length of the supporting post above ground (UK convention measures the *above-ground* len… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.
compute_utility_chamber Compute Utility Access Chamber BoQ ~645
Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Catalogue-driven utility access chamber covering ten standard UK types: BT/Openreach jointing chambers JC1-JC4 (defaulting to UTILITY_PROVIDER_SUPPLY routing), water meter chamber (FW6), wastewater inspection chamber (RW9), valve chamber, gas Emergency Control Valve pit (ECV), LV electrical link box, and cable draw pit. Composite emission: precast chamber unit + BS EN 124 cover & frame (PC supply) + excavation + bedding (SHW Cl. 803) + granular surround + optional geotextile + selected fill + disposal. Routes via manhole_type=utility_chamber attribute discrimination through CESMM4 Class K.1.5.x, NRM2 33.7.11-.13, MMHW 500.5.13-.15 (SHW Cl. 507), and SMM7 R12.3.10-.12. JC types route their chamber unit through the v18 statutory-undertaker supply route infrastructure (CESMM4 Class A.4.3, NRM2 Group 1, MMHW Series 100, SMM7 A53) as a PC sum plus contractor attendance line. Example params: bedding_thickness_mm=150 mm (75–300), bedding_overhang_m=0.1 m (0.075–0.3), surround_thickness_m=0.15 m (0.1–0.3). Example call: {"params": {"bedding_thickness_mm": 150, "bedding_overhang_m": 0.1, "surround_thickness_m": 0.15}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier).
| Name | Type | Req | Description |
|---|---|---|---|
| deliverables | — | — | — |
| output_mode | string | — | — |
| params | object | yes | Parameter form for a utility access chamber. Catalogue-driven: pick a ``chamber_type`` and the chamber's nominal plan dimensions, depth, wall thickness, cover loading and supply route default are re… |
| standard | string | — | — |
| Name | Type | Req | Description |
|---|---|---|---|
| result | — | yes | — |
No examples provided.