Skip to content
verify mcp Beta VerifyMCP is currently in beta. If you notice any issues, get in touch and we’ll put it right.

CADProps

REMOTE · WWW.CADPROPS.COM

Fast multi-format CAD previews, geometry checks and conversion; measure and share in the workspace.

Available components

+3 this week 70 Trust /100

Last scanned (9 hours ago)

Scores higher than 60% of remote servers

Reachable. Last reached 23 Oct 2026.

Category Design and Media

Trust breakdown (7 categories)

How this component scores in each security and reliability category. Every signal is checked automatically against the live server, and we only credit what we can confirm. How we score → Why this is hard to score →

Endpoint Security80
Transport & Reachability100
Schema Quality & AI Usability39
  • 0% of prompts and resources have a non-trivial description (not blank, and not just the item's name).Fail
  • AI-judged instruction clarity (fair).Partial
  • Context-footprint check failed: tool/resource definitions use about 615 tokens (~123/item across 5 items; 4 tools + 1 resources), over budget; trim descriptions and params. See how to fix → Fail
  • Usage-examples check failed: none of the tools include examples. See how to fix → Fail
Stability & Change Management33
  • Stability observed for 10 of 30 days with no destabilising changes; credit accrues until the full window elapses.Partial
Tool Coverage83
  • 100% of tools have a non-trivial description (not blank, and not just the tool's name).Pass
  • 40% of tool parameters carry a description.Partial
  • Structured output schemas are declared (25% of tools); any adoption earns full credit.Pass
Tool Safety100
  • No prompt-injection markers were found in the server instructions, tool names or descriptions we captured.Pass
  • We read all 4 captured tool definition(s), and no name or description among them implies an irreversible operation.Pass
  • An AI judge read all 5 captured unit(s) of tool text and found none that tries to manipulate the model reading it.Pass
Capabilities100
  • Implements a supported MCP spec version (2025-11-25); the latest is 2026-07-28.Pass
  • Supports UI / widget rendering.Pass
Changelog

Every change we have recorded for this component, newest first. Security-relevant changes are always shown. ▲ marks a change for the better, ▼ a change for the worse; unmarked changes are neutral.

  • 23 Oct 26 0
    • Tool “inspect_cad” rewrote its description, which is the text the model reads security
    • Schema quality: pass → fail ▼ functional
  • 22 Oct 26 +1
    • Tool “inspect_cad” rewrote its description, which is the text the model reads security
  • 20 Oct 26 +1

    No change was recorded against any check on this day. Stability & Change Management went from 20 to 23. That category is still filling its 30-day observation window: 6 days of observed history at the previous scan, 7 at this one. The score rises as the window fills, whether or not the server changes.

  • 19 Oct 26 0
    • Tool “inspect_cad” rewrote its description, which is the text the model reads security
  • 18 Oct 26 +1

    No change was recorded against any check on this day. Stability & Change Management went from 13 to 17. That category is still filling its 30-day observation window: 4 days of observed history at the previous scan, 5 at this one. The score rises as the window fills, whether or not the server changes.

  • 15 Oct 26 +1
    • Tool “inspect_cad” rewrote its description, which is the text the model reads security
  • 14 Oct 26 0
    • Tool “inspect_cad” rewrote its description, which is the text the model reads security
    • Stability: unverified → 0.03 ▲ functional
  • 13 Oct 26 66

    First indexed and scored.

Diagnostics

Diagnostic detail from the automated scan of this channel: what the scanner observed at each step, so you can see exactly where a check passed or failed. It is informational only and never changes the trust score.

Captured 23 Oct 2026 · Probed https://www.cadprops.com/api/v1/mcp

TLS valid

Negotiated TLS 1.3 with TLS_AES_128_GCM_SHA256 .

Subject Issuer Valid from Valid until Key Signature Serial
CN=cadprops.com CN=WE1,O=Google Trust Services,C=US 17 Sept 2026 16 Dec 2026 ECDSA 256 ECDSA-SHA256 39cb8c256d79ec490e02663137fd07ba
SANs: cadprops.com, www.cadprops.com, *.www.cadprops.com
CN=WE1,O=Google Trust Services,C=US (CA) CN=GTS Root R4,O=Google Trust Services LLC,C=US 13 Dec 2023 20 Feb 2029 ECDSA 256 ECDSA-SHA384 7ff31977972c224a76155d13b6d685e3
CN=GTS Root R4,O=Google Trust Services LLC,C=US (CA) CN=GlobalSign Root CA,OU=Root CA,O=GlobalSign nv-sa,C=BE 15 Nov 2023 28 Jan 2028 ECDSA 384 SHA256-RSA 7fe530bf331343bedd821610493d8a1b

Background: What to check on a remote MCP endpoint →

DNSSEC insecure

Validation of www.cadprops.com. — Not signed

Zone DS Keys Algorithms Outcome
. trust_anchor 20326, 38696 8, 8 Verified
com. present 19718 13 Verified
cadprops.com. absent Unsigned (proven) parent-signed NSEC/NSEC3 proves an unsigned delegation
Authentication No authorisation required

The endpoint answered without asking for a token. Anyone who knows the URL can reach it.

Result No authorisation required
HTTP status 200
Header Value
strict-transport-security max-age=31536000
x-content-type-options nosniff
x-frame-options DENY
referrer-policy no-referrer

Background: How OAuth 2.1 works in the 2026 MCP spec →

Transports 2 probes
Transport URL Outcome Status Location
streamable-http https://www.cadprops.com/api/v1/mcp Verified 200
http (plaintext) http://www.cadprops.com/api/v1/mcp HTTPS enforced 301 https://www.cadprops.com/api/v1/mcp
MCP tools · 4 exposed · ~606 tokens

The tools this component advertises to a client, with an estimated token cost for each. Expand a tool to see its parameters and schema. The per-tool counts are indicative and are not scored directly; the schema's total context footprint is one signal in Schema Quality & AI Usability. A tool's description is untrusted text the model reads on every call, which is what makes this list a security surface and not just an inventory: how tool poisoning works →

Tool Tokens
convert_cad ~122

Convert a file opened with inspect_cad to STEP, STL or GLB and return a download link that expires in 30 minutes. STEP is a solid B-Rep when the source was read exactly; otherwise it is a triangulated STEP that CAD software cannot edit as a solid. STL and GLB are always triangulated meshes.

NameTypeReqDescription
refstringyesThe ref from an inspect_cad result. An upload_ticket is not a ref.
step_kindstring––
targetstringyes–
wait_secondsinteger––

No output schema declared.

No examples provided.

inspect_cad ~378

Open a CAD file on CADProps servers and report its format, size, volume, area, units and accuracy, with an interactive 3D preview. Supported: 3DM, 3DXML, 3MF, 7Z, AMF, ASM, BMP, CATDRAWING, CATPART, CATPRODUCT, CGM, DFT, DRW, DWF, DWFX, DWG, DXF, EMF, F3D, GIF, GLB, GLTF, GZ, IAM, ICO, IDW, IFC, IFCZIP, IGES, IGS, IPT, JPG, JT, NEU, OBJ, PAR, PCX, PDF, PLT, PLY, PNG, PRC, PRT, PSM, RAR, SAB, SAT, SLDASM, SLDDRW, SLDPRT, STEP, STL, STP, SVG, TGA, TGZ, TIFF, U3D, UNV, VDA, VDAFS, VRML, WEBP, WMF, WRL, WRZ, X3D, X3DV, X_B, X_T, ZIP. Creo .prt files with supported saved triangle strips show a partial 3D preview with unverified units and no physical measurements. Other Creo .prt files, Creo .asm files and CATIA .CATProduct files show only the thumbnail saved in the file when available. Call with no file to get a one-time upload link. Files are deleted about one hour after upload.

NameTypeReqDescription
fileobject––
refstring–Reference returned by an earlier inspect_cad call.
upload_ticketstring–Ticket from a previous upload link, after the user says the upload is done.
wait_secondsinteger––
NameTypeReqDescription
area_mm2number|null––
bounding_box_mmobject|null––
expires_atstring––
failurestring|null––
filenamestring––
formatobject––
incompleteboolean––
measurement_accuracy–––
missing_componentsinteger––
part_countinteger––
precision_grade–––
precision_summary–––
refstring––
representationstring|null––
source_precision_qualified–––
statusstring––
step_outputstring––
unitsobject––
upload_ticketstring––
upload_urlstring––
volume_mm3number|null––
warningsarray––

No examples provided.

open_in_workspace ~77

Return a one-time link (valid 15 minutes) that opens this file in the CADProps web workspace for measuring, sectioning and sharing. After it is opened, the chat preview and links for this file stop working.

NameTypeReqDescription
refstringyesThe ref from an inspect_cad result. An upload_ticket is not a ref.

No output schema declared.

No examples provided.

refresh_view_token ~29

Used by the CADProps preview to renew its read-only token.

NameTypeReqDescription
refstringyes–

No output schema declared.

No examples provided.

Install

How do I install the CADProps MCP server?

CADProps is a hosted endpoint at https://www.cadprops.com/api/v1/mcp, so there is nothing to install locally. Ready-made configuration for Claude, Cursor, VS Code, Codex and 5 more is on this page, copied from each client's own documentation.

remote · www.cadprops.com

# add to Claude Code
claude mcp add --transport http com-cadprops-cadprops 'https://www.cadprops.com/api/v1/mcp'
Common questions

What is the CADProps MCP server?

CADProps is an MCP server listed in the public MCP registry as com.cadprops/cadprops. Fast multi-format CAD previews, geometry checks and conversion; measure and share in the workspace. This page covers its hosted endpoint (https://www.cadprops.com/api/v1/mcp).

Is the CADProps MCP server safe to use?

CADProps scores 70 out of 100 on VerifyMCP. That is a record of what we were able to check automatically, not an endorsement. The category breakdown on this page shows every signal behind the number, including the ones we could not confirm.

What tools does the CADProps MCP server expose?

CADProps exposes 4 tools: inspect_cad, convert_cad, open_in_workspace, refresh_view_token. Their descriptions and schemas cost roughly 606 tokens of context every time the server is loaded.

Does the CADProps MCP server require authentication?

No. We connected to CADProps without credentials and it answered, so anything it exposes is reachable by anyone who knows the address.

Is the CADProps MCP server still maintained?

CADProps is still listed as active in the MCP registry. We last reached this channel on 23 October 2026. Those dates come from our own scans of the registry and the channel itself, not from anything the publisher announced.