Skip to content
verify mcp Beta VerifyMCP is currently in beta. If you notice any issues, get in touch and we’ll put it right.

SparkQuote NEC calculators

REMOTE · SPARKQUOTE.AI

NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.

Available components

+3 this week 79 Trust /100

Last scanned (23 hours ago)

Scores higher than 79% of remote servers

Reachable. Last reached 4 Nov 2026.

Category IoT and Hardware

Trust breakdown (7 categories)

How this component scores in each security and reliability category. Every signal is checked automatically against the live server, and we only credit what we can confirm. How we score → Why this is hard to score →

Endpoint Security80
Transport & Reachability100
Schema Quality & AI Usability60
  • AI-judged instruction clarity (good).Pass
  • Context-footprint check failed: tool/resource definitions use about 2135 tokens (~213/item across 10 items; 10 tools + 0 resources), over budget; trim descriptions and params. See how to fix → Fail
  • Usage-examples check failed: none of the tools include examples. See how to fix → Fail
Stability & Change Management70
  • Stability observed for 21 of 30 days with no destabilising changes; credit accrues until the full window elapses.Partial
Tool Coverage100
  • 100% of tools have a non-trivial description (not blank, and not just the tool's name).Pass
  • 100% of tool parameters carry a description.Pass
  • Structured output schemas are declared (100% of tools); any adoption earns full credit.Pass
Tool Safety75
  • No prompt-injection markers were found in the server instructions, tool names or descriptions we captured.Pass
  • 0 of 1 tool(s) whose name or description implies an irreversible operation declare an MCP destructiveHint annotation; "voltage_drop" implies "drop" and declares readOnlyHint instead, contradicting what its own name says it does. See how to fix → Fail
  • An AI judge read all 11 captured unit(s) of tool text and found none that tries to manipulate the model reading it.Pass
Capabilities100
  • Implements a supported MCP spec version (2025-11-25); the latest is 2026-07-28.Pass
Changelog

Every change we have recorded for this component, newest first. Security-relevant changes are always shown. ▲ marks a change for the better, ▼ a change for the worse; unmarked changes are neutral.

  • 3 Nov 26 +1

    No change was recorded against any check on this day. Stability & Change Management went from 63 to 67. That category is still filling its 30-day observation window: 19 days of observed history at the previous scan, 20 at this one. The score rises as the window fills, whether or not the server changes.

  • 1 Nov 26 +1

    No change was recorded against any check on this day. Stability & Change Management went from 57 to 60. That category is still filling its 30-day observation window: 17 days of observed history at the previous scan, 18 at this one. The score rises as the window fills, whether or not the server changes.

  • 30 Oct 26 +1

    No change was recorded against any check on this day. Stability & Change Management went from 50 to 53. That category is still filling its 30-day observation window: 15 days of observed history at the previous scan, 16 at this one. The score rises as the window fills, whether or not the server changes.

  • 28 Oct 26 +1

    No change was recorded against any check on this day. Stability & Change Management went from 43 to 47. That category is still filling its 30-day observation window: 13 days of observed history at the previous scan, 14 at this one. The score rises as the window fills, whether or not the server changes.

  • 26 Oct 26 +1

    No change was recorded against any check on this day. Stability & Change Management went from 37 to 40. That category is still filling its 30-day observation window: 11 days of observed history at the previous scan, 12 at this one. The score rises as the window fills, whether or not the server changes.

  • 23 Oct 26 +1

    No change was recorded against any check on this day. Stability & Change Management went from 27 to 30. That category is still filling its 30-day observation window: 8 days of observed history at the previous scan, 9 at this one. The score rises as the window fills, whether or not the server changes.

  • 21 Oct 26 +1

    No change was recorded against any check on this day. Stability & Change Management went from 20 to 23. That category is still filling its 30-day observation window: 6 days of observed history at the previous scan, 7 at this one. The score rises as the window fills, whether or not the server changes.

  • 19 Oct 26 +1

    No change was recorded against any check on this day. Stability & Change Management went from 13 to 17. That category is still filling its 30-day observation window: 4 days of observed history at the previous scan, 5 at this one. The score rises as the window fills, whether or not the server changes.

Diagnostics

Diagnostic detail from the automated scan of this channel: what the scanner observed at each step, so you can see exactly where a check passed or failed. It is informational only and never changes the trust score.

Captured 4 Nov 2026 · Probed https://sparkquote.ai/mcp

TLS valid

Negotiated TLS 1.3 with TLS_AES_128_GCM_SHA256 .

Subject Issuer Valid from Valid until Key Signature Serial
CN=*.sparkquote.ai CN=YR1,O=Let's Encrypt,C=US 7 Oct 2026 5 Jan 2027 RSA 2048 SHA256-RSA 6c28589a5a13c7fd6dbcc11bc70f6ee230c
SANs: *.sparkquote.ai, sparkquote.ai
CN=YR1,O=Let's Encrypt,C=US (CA) CN=Root YR,O=ISRG,C=US 3 Sept 2025 2 Sept 2028 RSA 2048 SHA256-RSA a20253f15f2691c05dc1ce13b9bcca4e
CN=Root YR,O=ISRG,C=US (CA) CN=ISRG Root X1,O=Internet Security Research Group,C=US 13 May 2026 2 Sept 2032 RSA 4096 SHA256-RSA f24b6d17f9d9ad7cb1c9fea78782699f

Background: What to check on a remote MCP endpoint →

DNSSEC insecure

Validation of sparkquote.ai. — Not signed

Zone DS Keys Algorithms Outcome
. trust_anchor 20326, 38696 8, 8 Verified
ai. present 1814, 3799 8, 8 Verified
sparkquote.ai. absent Unsigned (proven) parent-signed NSEC/NSEC3 proves an unsigned delegation
Authentication No authorisation required

The endpoint answered without asking for a token. Anyone who knows the URL can reach it.

Result No authorisation required
HTTP status 200
Header Value
strict-transport-security max-age=63072000
x-content-type-options nosniff
x-frame-options DENY
referrer-policy strict-origin-when-cross-origin
permissions-policy camera=(), microphone=(), geolocation=()

Background: How OAuth 2.1 works in the 2026 MCP spec →

Transports 2 probes
Transport URL Outcome Status Location
streamable-http https://sparkquote.ai/mcp Verified 200
http (plaintext) http://sparkquote.ai/mcp HTTPS enforced 308 https://sparkquote.ai/mcp
MCP tools · 10 exposed · ~2,031 tokens

The tools this component advertises to a client, with an estimated token cost for each. Expand a tool to see its parameters and schema. The per-tool counts are indicative and are not scored directly; the schema's total context footprint is one signal in Schema Quality & AI Usability. A tool's description is untrusted text the model reads on every call, which is what makes this list a security surface and not just an inventory: how tool poisoning works →

Tool Tokens
bid_calculator ~132

Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).

NameTypeReqDescription
directnumber–Permits and other job costs ($). Optional.
hoursnumberyesLabor hours (h).
marginnumberyesTarget net margin (%).
markupnumber–Material markup (%). Optional.
materialsnumberyesMaterial cost ($).
overheadnumberyesOverhead (% of direct cost) (%).
ratenumberyesBurdened labor cost ($/h).
NameTypeReqDescription
codestringyes–
inputsobjectyes–
okbooleanyes–
rowsarrayyes–
summarystringyes–
tableobject––
urlstringyes–

No examples provided.

box_fill ~198

Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.

NameTypeReqDescription
awgstringyesLargest conductor. "6" = 6 AWG; "8" = 8 AWG; "10" = 10 AWG; "12" = 12 AWG; "14" = 14 AWG; "16" = 16 AWG; "18" = 18 AWG.
clampsstringyesInternal cable clamps. "0" = None; "1" = One or more.
conductorsnumberyesInsulated conductors (not counting grounds).
devicesnumberyesDevices (switches, receptacles).
groundsstringyesEquipment grounding conductors. "0" = None; "1" = One or more.
NameTypeReqDescription
codestringyes–
inputsobjectyes–
okbooleanyes–
rowsarrayyes–
summarystringyes–
tableobject––
urlstringyes–

No examples provided.

conduit_fill ~356

Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.

NameTypeReqDescription
awgstringyesTHHN/THWN-2 size. "1" = 1 AWG; "2" = 2 AWG; "3" = 3 AWG; "4" = 4 AWG; "6" = 6 AWG; "8" = 8 AWG; "10" = 10 AWG; "12" = 12 AWG; "14" = 14 AWG; "1/0" = 1/0 AWG; "2/0" = 2/0 AWG; "3/0" = 3/0 AWG; "4/0" =…
countnumberyesNumber of conductors.
sizestringyesTrade size. "1" = 1"; "2" = 2"; "3" = 3"; "4" = 4"; "1/2" = 1/2"; "3/4" = 3/4"; "1-1/4" = 1-1/4"; "1-1/2" = 1-1/2"; "2-1/2" = 2-1/2"; "3-1/2" = 3-1/2".
typestringyesConduit type. "EMT" = EMT; "PVC-40" = PVC Schedule 40.
NameTypeReqDescription
codestringyes–
inputsobjectyes–
okbooleanyes–
rowsarrayyes–
summarystringyes–
tableobject––
urlstringyes–

No examples provided.

load_calculator ~224

Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.

NameTypeReqDescription
dishwashernumber–Dishwasher (VA). Optional.
disposalnumber–Disposal (VA). Optional.
dryernumber–Dryer (VA). Optional.
evnumber–EV charger (VA). Optional.
heaternumber–Water heater (VA). Optional.
hvacnumber–Largest of heating or cooling (VA). Optional.
laundrystringyesLaundry circuit. "1" = Yes (1,500 VA); "0" = No.
othernumber–Other fixed appliances (VA). Optional.
rangenumber–Range / cooktop (VA). Optional.
smallnumberyesSmall-appliance circuits.
sqftnumberyesLiving area (ft²).
NameTypeReqDescription
codestringyes–
inputsobjectyes–
okbooleanyes–
rowsarrayyes–
summarystringyes–
tableobject––
urlstringyes–

No examples provided.

nec_ampacity ~157

Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.

NameTypeReqDescription
materialstringyes"cu" = copper; "al" = aluminum.
sizestringyesConductor size: AWG ("14" … "4/0") or kcmil ("250" … "500").
tempstringyesTemperature column in °C: 60 (NM-B, UF), 75 (THWN, most terminations), 90 (THHN, for derating).
NameTypeReqDescription
codestringyes–
inputsobjectyes–
okbooleanyes–
rowsarrayyes–
summarystringyes–
tableobject––
urlstringyes–

No examples provided.

ohms_law ~83

Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.

NameTypeReqDescription
inumber–Current (A). Optional.
pnumber–Power (W). Optional.
rnumber–Resistance (Ω). Optional.
vnumber–Voltage (V). Optional.
NameTypeReqDescription
codestringyes–
inputsobjectyes–
okbooleanyes–
rowsarrayyes–
summarystringyes–
tableobject––
urlstringyes–

No examples provided.

panel_schedule ~139

Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.

NameTypeReqDescription
circuitsstringyesCircuits: description, breaker A, poles, VA (one per line)
spacesstringyesSpaces. "12" = 12; "20" = 20; "24" = 24; "30" = 30; "42" = 42.
systemstringyesPanel. "1" = 120/240 V single-phase; "3" = 208Y/120 V three-phase.
NameTypeReqDescription
codestringyes–
inputsobjectyes–
okbooleanyes–
rowsarrayyes–
summarystringyes–
tableobject––
urlstringyes–

No examples provided.

voltage_drop ~366

Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).

NameTypeReqDescription
ampsnumberyesLoad current (A).
awgstringyesSize. "14" = 14 AWG; "12" = 12 AWG; "10" = 10 AWG; "8" = 8 AWG; "6" = 6 AWG; "4" = 4 AWG; "3" = 3 AWG; "2" = 2 AWG; "1" = 1 AWG; "1/0" = 1/0 AWG; "2/0" = 2/0 AWG; "3/0" = 3/0 AWG; "4/0" = 4/0 AWG; "2…
feetnumberyesOne-way distance (ft).
materialstringyesConductor. "cu" = Copper; "al" = Aluminum.
phasestringyesPhase. "1" = Single-phase; "3" = Three-phase.
voltsstringyesVoltage. "120" = 120 V; "208" = 208 V; "240" = 240 V; "277" = 277 V; "480" = 480 V.
NameTypeReqDescription
codestringyes–
inputsobjectyes–
okbooleanyes–
rowsarrayyes–
summarystringyes–
tableobject––
urlstringyes–

No examples provided.

watts_to_amps ~128

Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.

NameTypeReqDescription
pfnumberyesPower factor.
phasestringyesPhase. "1" = Single-phase; "3" = Three-phase.
voltsstringyesVoltage. "120" = 120 V; "208" = 208 V; "240" = 240 V; "277" = 277 V; "480" = 480 V.
wattsnumberyesPower (W).
NameTypeReqDescription
codestringyes–
inputsobjectyes–
okbooleanyes–
rowsarrayyes–
summarystringyes–
tableobject––
urlstringyes–

No examples provided.

wire_size ~248

Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors.

NameTypeReqDescription
ampsnumberyesBreaker / load (A).
feetnumberyesOne-way distance (ft).
limitnumberyesMax voltage drop (%).
materialstringyesConductor. "cu" = Copper; "al" = Aluminum.
phasestringyesPhase. "1" = Single-phase; "3" = Three-phase.
tempstringyesTermination rating. "60" = 60°C (NM-B, UF); "75" = 75°C (THHN in conduit); "90" = 90°C.
voltsstringyesVoltage. "120" = 120 V; "208" = 208 V; "240" = 240 V; "277" = 277 V; "480" = 480 V.
NameTypeReqDescription
codestringyes–
inputsobjectyes–
okbooleanyes–
rowsarrayyes–
summarystringyes–
tableobject––
urlstringyes–

No examples provided.

Install

How do I install the SparkQuote NEC calculators MCP server?

SparkQuote NEC calculators is a hosted endpoint at https://sparkquote.ai/mcp, so there is nothing to install locally. Ready-made configuration for Claude, Cursor, VS Code, Codex and 5 more is on this page, copied from each client's own documentation.

remote · sparkquote.ai

# add to Claude Code
claude mcp add --transport http ai-sparkquote-nec-calculators 'https://sparkquote.ai/mcp'
Common questions

What is the SparkQuote NEC calculators MCP server?

SparkQuote NEC calculators is an MCP server listed in the public MCP registry as ai.sparkquote/nec-calculators. NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load. This page covers its hosted endpoint (https://sparkquote.ai/mcp).

Is the SparkQuote NEC calculators MCP server safe to use?

SparkQuote NEC calculators scores 79 out of 100 on VerifyMCP. That is a record of what we were able to check automatically, not an endorsement. The category breakdown on this page shows every signal behind the number, including the ones we could not confirm.

What tools does the SparkQuote NEC calculators MCP server expose?

SparkQuote NEC calculators exposes 10 tools: wire_size, voltage_drop, watts_to_amps, conduit_fill, box_fill, and 5 more. Their descriptions and schemas cost roughly 2,031 tokens of context every time the server is loaded.

Does the SparkQuote NEC calculators MCP server require authentication?

No. We connected to SparkQuote NEC calculators without credentials and it answered, so anything it exposes is reachable by anyone who knows the address.

Is the SparkQuote NEC calculators MCP server still maintained?

SparkQuote NEC calculators is still listed as active in the MCP registry. We last reached this channel on 4 November 2026. Those dates come from our own scans of the registry and the channel itself, not from anything the publisher announced.