# PlanElec Calculators (remote · planelec.be)

Free AREI cable sizing, Synergrid C10/26 inverter check, LED strip calculator. No account.

- Trust score: 78/100 (medium)
- Change this week: +3
- Registry status: active
- Liveness: live
- Owner verified: no
- Last scored: 2026-11-21

## Components

- remote · `planelec.be`: 78/100 (this document), [markdown](https://verifymcp.io/servers/be-planelec-calculators/mcp-public.md), [page](https://verifymcp.io/servers/be-planelec-calculators/mcp-public)

## Channel facts

- Endpoint: `https://planelec.be/mcp/public`
- Transports: `streamable-http`
- Auth: `none`
- Version: `0.2.0`

## Trust breakdown

How this component scores in each security and reliability category. Every signal is checked automatically against the live server, and we only credit what we can confirm. Scores are 0–100 per category. Scoring method: https://verifymcp.io/docs/scoring (what has changed: https://verifymcp.io/docs/scoring/changelog)

Scored 2026-11-21.

- **Endpoint Security**: 80/100
  - The endpoint's TLS certificate is valid, in date, and uses a strong key.
  - No authorisation is required to call this server. Nothing on it is marked destructive, but we can't show that an anonymous caller can only read: full credit needs the server to list at least one tool and every tool to be verifiably read-only. We use a best-effort check of tool names and descriptions to tell read-only tools from tools that change things, so some genuinely read-only tools may not get full credit. Names that start with a read verb (get, list, read, search and similar) and accurate readOnlyHint annotations help. Meet that to earn full credit, or require authorisation.
  - HTTPS is enforced; there's no plaintext access path.
  - The HSTS (Strict-Transport-Security) header is present.
  - DNSSEC check failed: this domain isn't protected by DNSSEC.
- **Transport & Reachability**: 100/100
  - Verified streamable-http transport via a live MCP handshake.
- **Schema Quality & AI Usability**: 61/100
  - AI-judged instruction clarity (excellent).
  - Context-footprint check failed: tool/resource definitions use about 2211 tokens (~276/item across 8 items; 8 tools + 0 resources), over budget; trim descriptions and params.
  - Usage-examples check failed: none of the tools include examples.
- **Stability & Change Management**: 53/100
  - Stability observed for 16 of 30 days with no destabilising changes; credit accrues until the full window elapses.
- **Tool Coverage**: 100/100
  - 100% of tools have a non-trivial description (not blank, and not just the tool's name).
  - 100% of tool parameters carry a description.
  - Structured output schemas are declared (100% of tools); any adoption earns full credit.
- **Tool Safety**: 100/100
  - No prompt-injection markers were found in the server instructions, tool names or descriptions we captured.
  - We read all 8 captured tool definition(s), and no name or description among them implies an irreversible operation.
  - An AI judge read all 9 captured unit(s) of tool text and found none that tries to manipulate the model reading it.
- **Capabilities**: 100/100
  - Implements a supported MCP spec version (2025-11-25); the latest is 2026-07-28.

## Install

### How do I install the PlanElec Calculators MCP server?

PlanElec Calculators is a hosted endpoint at https://planelec.be/mcp/public, so there is nothing to install locally. Ready-made configuration for Claude, Cursor, VS Code, Codex and 5 more is on this page, copied from each client's own documentation.

### Claude

```bash
claude mcp add --transport http be-planelec-calculators 'https://planelec.be/mcp/public'
```

### Cursor

```json
{
  "mcpServers": {
    "be-planelec-calculators": {
      "url": "https://planelec.be/mcp/public"
    }
  }
}
```

### VS Code

```json
{
  "servers": {
    "be-planelec-calculators": {
      "type": "http",
      "url": "https://planelec.be/mcp/public"
    }
  }
}
```

### Codex

```toml
[mcp_servers.be-planelec-calculators]
url = "https://planelec.be/mcp/public"
```

### opencode

```json
{
  "$schema": "https://opencode.ai/config.json",
  "mcp": {
    "be-planelec-calculators": {
      "type": "remote",
      "url": "https://planelec.be/mcp/public",
      "enabled": true
    }
  }
}
```

### OpenClaw

```bash
openclaw mcp add be-planelec-calculators --url 'https://planelec.be/mcp/public' --transport streamable-http
```

### Hermes

```yaml
mcp_servers:
  be-planelec-calculators:
    url: "https://planelec.be/mcp/public"
```

### Netclaw

```json
{
  "McpServers": {
    "be-planelec-calculators": {
      "Transport": "http",
      "Url": "https://planelec.be/mcp/public"
    }
  }
}
```

### Vellum

```bash
assistant mcp add be-planelec-calculators -t streamable-http -u 'https://planelec.be/mcp/public'
```

### Other

```json
{
  "mcpServers": {
    "be-planelec-calculators": {
      "type": "http",
      "url": "https://planelec.be/mcp/public"
    }
  }
}
```

The mcpServers block is a cross-client convention. Remote transports vary, so check your client's docs.

## Changelog

Every change recorded for this component, newest first. Days that predate change tracking, or that we cannot explain, say so: "we were watching and nothing happened" and "we were not watching" are different claims.

### 2026-11-19 (score 78, +1)

No change was recorded against any check on this day. Stability & Change Management went from 43 to 47. That category is still filling its 30-day observation window: 13 days of observed history at the previous scan, 14 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-11-17 (score 77, +1)

No change was recorded against any check on this day. Stability & Change Management went from 37 to 40. That category is still filling its 30-day observation window: 11 days of observed history at the previous scan, 12 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-11-15 (score 76, +1)

No change was recorded against any check on this day. Stability & Change Management went from 30 to 33. That category is still filling its 30-day observation window: 9 days of observed history at the previous scan, 10 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-11-13 (score 75, +1)

No change was recorded against any check on this day. Stability & Change Management went from 23 to 27. That category is still filling its 30-day observation window: 7 days of observed history at the previous scan, 8 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-11-11 (score 74, +1)

No change was recorded against any check on this day. Stability & Change Management went from 17 to 20. That category is still filling its 30-day observation window: 5 days of observed history at the previous scan, 6 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-11-09 (score 73, +1)

No change was recorded against any check on this day. Stability & Change Management went from 10 to 13. That category is still filling its 30-day observation window: 3 days of observed history at the previous scan, 4 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-11-07 (score 72, +1)

No change was recorded against any check on this day. Stability & Change Management went from 3 to 7. That category is still filling its 30-day observation window: 1 days of observed history at the previous scan, 2 at this one. The score rises as the window fills, whether or not the server changes.

### 2026-11-06 (score 71, 0)

- [functional improvement] Stability: unverified → 0.03

## MCP tools (8)

### `check_inverter_c10_26` (~245 tokens)

Check an inverter against Synergrid C10/26

Checks whether a PV inverter, battery inverter or other power-generating unit (PGU) is on the Synergrid C10/26 list of devices homologated for connection to the Belgian grid. Returns the outcome (found, found_with_limitations, expired, not_found, brand), matching devices with homologation dates, limitations and firmware versions, and homologated alternatives when nothing matches. Where available, each match also carries a separate "datasheet" object with manufacturer datasheet values (DC voltage, MPPT data, links, source URLs, status, last verified date); these are NOT checked by Synergrid and are not part of the approval. Search by brand and model, for example "Huawei SUN2000-10KTL".

Input parameters:

- `locale` (string): Language of source titles and links (nl, fr, de, en). Defaults to the server setting.
- `phases` (number): Optional: 1 or 3 phases, improves alternative suggestions.
- `query` (string, required): Brand and/or model, 2–80 characters.
- `smaxVa` (number): Optional: apparent power in VA, improves alternative suggestions.

Output parameters:

- `alternatives` (array)
- `dataDate` (string|null)
- `matches` (array)
- `nextSteps` (array)
- `officialSource` (object)
- `outcome` (string)
- `source` (object)

### `suggest_inverter_c10_26` (~116 tokens)

Suggest brands or models from the Synergrid C10/26 list

Typeahead for the Synergrid C10/26 list: given a partial brand or model name, returns matching brands with device counts or, once a brand is recognised, its homologated models. Use this to resolve an ambiguous device name before calling check_inverter_c10_26.

Input parameters:

- `locale` (string): Language of source titles and links (nl, fr, de, en). Defaults to the server setting.
- `query` (string, required): Partial brand or model name, 1–80 characters.

Output parameters:

- `brands` (array)
- `matchedBrand` (string|null)
- `models` (array)
- `source` (object)

### `get_inverter_datasheet` (~247 tokens)

Get inverter datasheet data

Returns manufacturer datasheet data for an inverter from the Synergrid C10/26 list: maximum DC voltage, MPPT count and range, current limits per MPPT, start voltage, maximum PV power, battery capability, optimizer architecture, links to the datasheet and installation manual, the product photo URL, source URL and page per value, status (verified = stated in the datasheet, secondary = unconfirmed) and the date last verified. These are manufacturer statements and are NOT part of the Synergrid approval; use check_inverter_c10_26 for the approval status. Look up by Synergrid reference (GLV…) or by brand and model.

Input parameters:

- `brand` (string): Brand, e.g. Huawei. Use together with model.
- `locale` (string): Language of source titles and links (nl, fr, de, en). Defaults to the server setting.
- `model` (string): Model designation, e.g. SUN2000-5KTL-M1. Use together with brand.
- `reference` (string): Synergrid reference, e.g. GLV073-06-0020. Alternative to brand and model.

Output parameters:

- `datasheet` (object)
- `note` (string)
- `source` (object)

### `size_cable_arei` (~389 tokens)

Size a cable per AREI/RGIE

Calculates the required copper or aluminium cable cross-section for a residential circuit under the Belgian AREI/RGIE: design current, voltage drop per cross-section, protection check against the breaker rating and the recommended cross-section. Provide the load (A, W, kW or kVA), one-way cable length in metres, the network (1x230V, 3x230V, 3x400V) and the breaker rating; other fields use the defaults for a typical socket circuit. The response includes a shareable link that opens the same calculation on planelec.be.

Input parameters:

- `breakerAmps` (number): Circuit-breaker rating in A. Default: 16.
- `circuitKind` (string): ‘lighting’ applies the 3% voltage-drop limit, ‘other’ 5%.
- `circuitPhases` (string): Circuit type; three-phase requires a 3x network.
- `cosPhi` (number): Power factor 0–1. Default: 0.95.
- `lengthM` (number): One-way cable length in metres. Default: 30.
- `loadUnit` (string): Unit of loadValue. Default: A.
- `loadValue` (number): Load magnitude in loadUnit. Default: 16.
- `locale` (string): Language of source titles and links (nl, fr, de, en). Defaults to the server setting.
- `material` (string): Conductor material. Default: CU.
- `mode` (string): ‘plan’ recommends a cross-section; ‘check’ evaluates selectedCrossSectionMm2.
- `network` (string): Supply network. Default: 1x230V.
- `nominalVoltage` (number): Optional override of the nominal voltage (≤ 1000 V).
- `selectedCrossSectionMm2` (number): Cross-section to evaluate in ‘check’ mode.

Output parameters:

- `activePowerW` (number)
- `comparison` (array)
- `currentAmps` (number)
- `input` (object)
- `maxVoltageDropPercent` (number)
- `nextSteps` (array)
- `nominalVoltage` (number)
- `overallStatus` (string)
- `source` (object)

### `calculate_led_strip` (~492 tokens)

Calculate an LED strip: current, power supply, feed points

Calculates power, current (total and per channel), required feed points, power-supply size and the extra-low-voltage feed cable for an analogue LED strip (5/12/24/48 V DC; single colour, CCT, RGB, RGBW, RGB+CCT). Provide the strip length in metres and either a preset or the datasheet values (voltage, colour channels, watts per metre at full load). Optional: cut unit, maximum length per feed, number of feeds, power-supply reserve, feed-cable length, material and cross-section, and voltage-drop limit. Planning values from datasheet data, not a manufacturer guarantee; current-carrying capacity, heat and AREI/RGIE rules for SELV, bathrooms and outdoor areas are not checked. The response includes a shareable link that opens the calculation on planelec.be.

Input parameters:

- `colorMode` (string): Colour channels: mono, cct, rgb, rgbw or rgbcct. Default: mono.
- `cutUnitMm` (number): Cut unit in mm; the length is rounded down to it.
- `feedCrossSectionMm2` (number): Planned feed-cable cross-section in mm²; omit for a recommendation only.
- `feedLengthM` (number): One-way feed-cable length from power supply to strip in m. Default: 5.
- `feedMaterial` (string): Feed-cable conductor material. Default: CU.
- `feeds` (integer): Planned number of feed points; defaults to the minimum.
- `lengthM` (number, required): Strip length in metres.
- `locale` (string): Language of source titles and links (nl, fr, de, en). Defaults to the server setting.
- `maxFeedDropPercent` (number): Feed-cable voltage-drop limit in percent (planning assumption). Default: 3.
- `maxRunM` (number): Manufacturer's maximum strip length per feed in m. Default: 5.
- `powerPerMeterW` (number): Power per metre in W with all channels at full brightness. Default: 14.4.
- `preset` (string): Typical strip class as starting values; explicit fields override it.
- `psuReservePercent` (number): Power-supply reserve in percent. Default: 20.
- `voltage` (number): Strip nominal voltage in V DC. Default: 24.

Output parameters:

- `channels` (number)
- `currentA` (number)
- `feedComparison` (array)
- `feeds` (number)
- `input` (object)
- `nextSteps` (array)
- `overallStatus` (string)
- `powerW` (number)
- `psuRequiredW` (number)
- `requiredFeeds` (number)
- `source` (object)
- `warnings` (array)

### `search_help_guides` (~120 tokens)

Search the PlanElec help center

Searches the PlanElec guides about getting started, automatic planning, document exports, AREI self-check coverage, floor plan import, symbols and circuits in the visitor’s current language. Returns up to five guides with title, summary, category and a link to the full article; the article text itself is not returned.

Input parameters:

- `locale` (string): Language of source titles and links (nl, fr, de, en). Defaults to the server setting.
- `query` (string): Keywords matched against title, summary and tags. Empty lists all guides.

Output parameters:

- `results` (array)
- `source` (object)

### `search_regelwerk` (~258 tokens)

Search the Belgian AREI/RGIE regulations

Searches Book 1 of the Belgian AREI/RGIE (Royal Decree on electrical installations) in the language of the text: Dutch, French or German; English uses the German text. Returns up to ten articles with number, title, an excerpt, the edition in force today and a link to the article in the PlanElec reader; the full article text is not returned, use get_regelwerk_article for it. Search by keywords or by article number such as 4.2.4.3. Results are planning aids, not an official inspection.

Input parameters:

- `limit` (integer): Maximum number of articles, 1–10. Default: 5.
- `locale` (string): Language of source titles and links (nl, fr, de, en). Defaults to the server setting.
- `query` (string, required): Keywords or an article number such as 5.2.2.1 or 4.2.4.3, 2–120 characters.
- `version` (string): Optional edition, e.g. v06 or v07. Default: the edition in force today (v06 until 31/10/2026, v07 from 01/11/2026).

Output parameters:

- `edition` (object)
- `results` (array)
- `source` (object)

### `get_regelwerk_article` (~240 tokens)

Read an AREI/RGIE article

Returns the text of one article of Book 1 of the Belgian AREI/RGIE by its number (for example 4.2.4.3 or "AREI 7.1.4.3"), in the language of the text (Dutch, French or German; English uses the German text), with the edition, change notices of amending decrees, the titles of its sub-articles and a link to the article in the PlanElec reader. Cite the article number and edition when you pass the content on. Use search_regelwerk to find the number.

Input parameters:

- `article` (string, required): Article number such as 4.2.4.3; a prefix such as "AREI" or "RGIE" is accepted.
- `locale` (string): Language of source titles and links (nl, fr, de, en). Defaults to the server setting.
- `version` (string): Optional edition, e.g. v06 or v07. Default: the edition in force today (v06 until 31/10/2026, v07 from 01/11/2026).

Output parameters:

- `article` (string)
- `changes` (array)
- `edition` (object)
- `source` (object)
- `subArticles` (array)
- `text` (string)
- `title` (string)
- `truncated` (boolean)

## Diagnostics

Captured diagnostic sections: TLS, DNSSEC, Authorisation, Transports. The full working is on the page: https://verifymcp.io/servers/be-planelec-calculators/mcp-public#diagnostics

## Score history

- 2026-11-21: 78
- 2026-11-20: 78
- 2026-11-19: 78
- 2026-11-18: 77
- 2026-11-17: 77
- 2026-11-16: 76
- 2026-11-15: 76
- 2026-11-14: 75
- 2026-11-13: 75
- 2026-11-12: 74
- 2026-11-11: 74
- 2026-11-10: 73
- 2026-11-09: 73
- 2026-11-08: 72
- 2026-11-07: 72
- 2026-11-06: 71
- 2026-11-05: 71

## Common questions

### What is the PlanElec Calculators MCP server?

PlanElec Calculators is an MCP server listed in the public MCP registry as be.planelec/calculators. Free AREI cable sizing, Synergrid C10/26 inverter check, LED strip calculator. No account. This page covers its hosted endpoint (https://planelec.be/mcp/public).

### Is the PlanElec Calculators MCP server safe to use?

PlanElec Calculators scores 78 out of 100 on VerifyMCP. That is a record of what we were able to check automatically, not an endorsement. The category breakdown on this page shows every signal behind the number, including the ones we could not confirm.

### What tools does the PlanElec Calculators MCP server expose?

PlanElec Calculators exposes 8 tools: check_inverter_c10_26, suggest_inverter_c10_26, get_inverter_datasheet, size_cable_arei, calculate_led_strip, and 3 more. Their descriptions and schemas cost roughly 2,107 tokens of context every time the server is loaded.

### Does the PlanElec Calculators MCP server require authentication?

No. We connected to PlanElec Calculators without credentials and it answered, so anything it exposes is reachable by anyone who knows the address.

### Is the PlanElec Calculators MCP server still maintained?

PlanElec Calculators is still listed as active in the MCP registry. We last reached this channel on 21 November 2026. Those dates come from our own scans of the registry and the channel itself, not from anything the publisher announced.

### What did VerifyMCP test on the PlanElec Calculators MCP server?

VerifyMCP ran 13 checks on PlanElec Calculators, covering TLS certificate, Authorization, HTTPS, HSTS header and 9 more. Supply Chain Security and Provenance & Transparency do not apply to a hosted endpoint, so they were not tested. The score does not measure everything, and the scoring documentation lists what it leaves out.

## Links

- Remote endpoint: https://planelec.be/mcp/public
- Website: https://planelec.be/integrations/ai-assistants
- Changelog RSS feed: https://verifymcp.io/servers/be-planelec-calculators/mcp-public.xml
- Changelog JSON feed: https://verifymcp.io/servers/be-planelec-calculators/mcp-public/changelog.json
- Trust report (JSON): https://verifymcp.io/servers/be-planelec-calculators/mcp-public.json
- HTML version of this page: https://verifymcp.io/servers/be-planelec-calculators/mcp-public